Hybrid inverter · Wuxi Solinteg Power · CEC approved June 2026
CEC listing: MHS-3.6K-30 (AS4777-2 2020)
A 3.6 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Wuxi Solinteg Power MHS-3.6K-30, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 3.6 kW |
| Maximum power | 3.6 kW |
| Apparent power | 3.96 kVA |
| Efficiency | |
| Max efficiency | 97.6% |
| European efficiency | 97% |
| DC input & MPPT | |
| MPPT trackers | 1 |
| Max input voltage | 600 V |
| MPPT voltage min | 100 V |
| MPPT voltage max | 550 V |
| Max input current | 15 A |
| Battery & backup | |
| Battery compatible | Yes |
| Backup capable | Yes |
| Continuous backup | 3.6 kW |
| Physical | |
| Dimensions (H×W×D) | 418 × 534 × 210 mm |
| Weight | 27 kg |
| IP rating | IP65 |
| Cooling | Natural Convection |
| Operating temperature | -30°C to 60°C |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| Cable gauge | 4 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Wuxi Solinteg Power MHS-3.6K-30 against the closest-power inverters from other brands.
| Specification | Wuxi Solinteg Power MHS-3.6K-30Wuxi Solinteg Power | Energizer Force 3.6SEnergizer | Afore AF3.6K-SL-1Afore |
|---|---|---|---|
| Rated power? | 3.6 kW | 3.6 kW | 3.6 kW |
| Max efficiency? | 97.6% | Not on file | Not on file |
| MPPT trackers? | 1 | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Hybrid | Solar | Hybrid |
| Battery ready | Yes | No | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers defects in materials and workmanship for solar products. Key exclusions include damage from improper installation and environmental factors like floods.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.
GFCI FaultcriticalCall your installerGround leakage current exceeds the limitation.
ISO Over LimitationcriticalCall your installerDC side insulation impedance to the ground is too low.
N-PE Check FaultcriticalCall your installerGround cable is loose or poorly connected.
PV Over VoltagecriticalCall your installerPV input voltage exceeds the upper limit.
Relay Check FailcriticalCall your installerInternal relay self-check failed due to connection issue.
Bus Voltage FaultwarningCall your installerBus circuit voltage is too high.
DCI FaultwarningCall your installerDirect current injection value exceeds the tolerated range.
Grid Frequency FaultwarningCall your installerGrid frequency is higher or lower than the set protection value.
Grid Voltage FaultwarningCall your installerGrid voltage exceeds the limit of selected safety set range.
Inverter Over TemperaturewarningCall your installerHigh internal inverter temperature detected.
Mains LostwarningGrid power outage, AC switch or circuit is disconnected.
OGS-3.6K (AS4777-2 2020)
3.6 kW · 1φ
MHS-3K-30 (AS4777-2 2020)
3 kW · 1φ
MHS-4.2K-30 (AS4777-2 2020)
4.2 kW · 1φ
OGS-4.2K (AS4777-2 2020)
4.2 kW · 1φ
MHS-5K-30 (AS4777-2 2020)
5 kW · 1φ
OGS-5K (AS4777-2 2020)
5 kW · 1φ
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.