Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Vilion New Energy Technology
  4. MA1000K30

Battery inverter · Vilion New Energy Technology · CEC approved November 2026

Vilion New Energy Technology MA1000K30

CEC listing: MA1000K30 (AS4777-2 2020)

A 30 kW three-phase battery inverter.

Rated power
30kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
30kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
10yr
How long VILION (SHENZHEN) NEW ENERGY TECHNOLOGY CO LTD stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Vilion New Energy Technology MA1000K30, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Top clearance500 mm
Side clearance200 mm
AC breaker120 A
Cable gauge67 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
2 Nov 2026
Approval expiry
2 Nov 2029
Status
Active
Listed for STCs
Yes

About Vilion New Energy Technology

Australian office
Not verified
Category
Unknown
CEC-approved inverters
2
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

0 years on the CEC list

How it compares

The Vilion New Energy Technology MA1000K30 against the closest-power inverters from other brands.

Specification
Vilion New Energy Technology MA1000K30Vilion New Energy Technology
Afore AF30K-THAfore
Solplanet ASW030K-THSolplanet
Rated power?30 kW30 kW30 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeBatteryHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Vilion New Energy Technology MA1000K30

This warranty covers defects for 10 years if installed correctly; misuse and unauthorized modifications void it. Claims must be made with proof of purchase and product details.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, unauthorized repair or modification, damage due to negligence, and improper usage.
Environment limits
Usage outside recommended ambient temperature conditions.
Read the official warranty document (PDF)

Fault & error codes — Vilion New Energy Technology MA1000K30

From the install manual

19 documented

Showing 19 of 19. The official install manual is the authoritative source — always confirm before acting.

  • 01criticalCall your installer
    Manual (PDF)

    Fan is locked when inverter is off.

    Likely cause
    The fan may be obstructed or malfunctioning.
    What to do
    Check for obstructions; replace the fan if needed.
  • 02criticalCall your installer
    Manual (PDF)

    Over temperature

    Likely cause
    Inverter components are overheating due to poor ventilation or high ambient temperature.
    What to do
    Ensure proper ventilation; reduce ambient temperature if possible.
  • 03criticalCall your installer
    Manual (PDF)

    Battery voltage is too high

    Likely cause
    Overcharging or faulty battery.
    What to do
    Check battery status; ensure proper charging voltage.
  • 04criticalCall your installer
    Manual (PDF)

    Battery voltage is too low

    Likely cause
    Discharged battery or faulty connections.
    What to do
    Recharge or replace the battery; check connections.
  • 05criticalCall your installer
    Manual (PDF)

    Output short circuited.

    Likely cause
    Incorrect wiring or faulty appliance connected.
    What to do
    Disconnect the load and check wiring for faults.
  • 06criticalCall your installer
    Manual (PDF)

    Output voltage is too high.

    Likely cause
    Faulty inverter or external factors causing voltage spikes.
    What to do
    Check connections and appliances; reset the inverter if needed.
  • 07critical
    Manual (PDF)

    Overload time out

    Likely cause
    Devices connected exceed the inverter's capacity.
    What to do
    Reduce the load connected to the inverter.
  • 08criticalCall your installer
    Manual (PDF)

    Bus voltage is too high

    Likely cause
    Faulty components in the inverter.
    What to do
    Inspect inverter for faults; disconnect power.
  • 09criticalCall your installer
    Manual (PDF)

    Bus soft start failed

    Likely cause
    Failure in the internal circuitry.
    What to do
    Reset the inverter; if the issue persists, contact a technician.
  • 10criticalCall your installer
    Manual (PDF)

    PV over current

    Likely cause
    Excessive current coming from solar panels.
    What to do
    Check solar panel connections and current settings.
  • 11criticalCall your installer
    Manual (PDF)

    PV over voltage

    Likely cause
    Voltage from PV modules exceeds permitted limits.
    What to do
    Check the configuration of PV modules; adjust if necessary.
  • 12criticalCall your installer
    Manual (PDF)

    DCDC over current

    Likely cause
    Faulty or incorrect connections in the DC to DC converter.
    What to do
    Inspect DCDC connections and settings.
  • 13criticalCall your installer
    Manual (PDF)

    Battery discharge over current

    Likely cause
    Excessive load on the battery being discharged.
    What to do
    Reduce load on the battery; check for faults.
  • 51critical
    Manual (PDF)

    Over current

    Likely cause
    Load exceeding permissible limits.
    What to do
    Reduce connected load; check wiring.
  • 52criticalCall your installer
    Manual (PDF)

    Bus voltage is too low

    Likely cause
    Issues with the power supply or battery.
    What to do
    Inspect batteries and power sources; recharge as needed.
  • 53criticalCall your installer
    Manual (PDF)

    Inverter soft start failed

    Likely cause
    Faulty components or high load on startup.
    What to do
    Reduce load; reset the inverter; if still not working, contact technician.
  • 55criticalCall your installer
    Manual (PDF)

    Over DC voltage in AC output

    Likely cause
    Incorrect connections or malfunctioning inverter.
    What to do
    Inspect connections and settings; reset inverter.
  • 57criticalCall your installer
    Manual (PDF)

    Current sensor failed

    Likely cause
    Faulty current sensor within the inverter.
    What to do
    Inspect or replace the sensor.
  • 58criticalCall your installer
    Manual (PDF)

    Output voltage is too low

    Likely cause
    Low battery or short circuit.
    What to do
    Check battery status and all connections.

More VILION (SHENZHEN) NEW ENERGY TECHNOLOGY CO LTD inverters

MA1000K60 (AS4777-2 2020)

60 kW · 3φ

View all VILION (SHENZHEN) NEW ENERGY TECHNOLOGY CO LTD inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?