Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Victron Energy
  4. MultiPlus-II 48/3000/35-32 230V

Battery inverter · Victron Energy · CEC approved November 2023

Victron Energy MultiPlus-II 48/3000/35-32 230V

A 3 kW single-phase battery inverter.

Rated power
3kWHow much solar it can run at once
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3kW
How much solar it can turn into usable power at once
Max efficiency
93.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
5yr
How long Victron Energy BV stands behind it

Full datasheet

Every figure on file for the Victron Energy MultiPlus-II 48/3000/35-32 230V, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency93%
Physical
Weight19 kg
IP ratingIP22
Installation requirements
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
13 Nov 2023
Approval expiry
11 Feb 2027
Status
Active
Listed for STCs
Yes

About Victron Energy

Years on the CEC list
3 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
17
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
12.8 kWh
Annual yield
4,654 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Victron Energy MultiPlus-II 48/3000/35-32 230V against the closest-power inverters from other brands.

Specification
Victron Energy MultiPlus-II 48/3000/35-32 230VVictron Energy
Energizer FORCE 3.0HSEnergizer
Energizer Force 3SEnergizer
Rated power?3 kW3 kW3 kW
Max efficiency?93.0%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeBatteryHybridSolar
Battery readyYesYesNo
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Victron Energy MultiPlus-II 48/3000/35-32 230V

Victron Energy warrants its products to be free from defects in workmanship and materials for 5 years. To make a claim, please contact your place of purchase.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
misuse, neglect, improper installation, physical damage, modifications, and repairs by unauthorized personnel.
Environment limits
/
Read the official warranty document (PDF)

Fault & error codes — Victron Energy MultiPlus-II 48/3000/35-32 230V

From the install manual

4 documented

Showing 4 of 4. The official install manual is the authoritative source — always confirm before acting.

  • OVERLOADcritical
    Manual (PDF)

    Overload detected

    Likely cause
    The load exceeds the nominal output of the inverter.
    What to do
    Reduce the load.
  • RIPPLE_VOLTAGE_HIGHcritical
    Manual (PDF)

    Ripple voltage exceeds limits

    Likely cause
    Ripple voltage on DC connection exceeds acceptable levels.
    What to do
    Check the battery cables and battery connections. Ensure battery capacity is sufficient, and reset the inverter.
  • LOW_BATTERYwarning
    Manual (PDF)

    Low battery voltage

    Likely cause
    Battery voltage is low.
    What to do
    Charge the battery or check the battery connections.
  • TEMP_HIGHwarning
    Manual (PDF)

    High temperature warning

    Likely cause
    High environmental temperature or excessive load.
    What to do
    Install the inverter in a cooler environment, or reduce the load.

More Victron Energy BV inverters

MultiPlus-II 48/3000/35-32 230V AU (AS4777-2 2020)

3 kW · 1φ

MultiPlus-II 48/3000/35-32 230V GX

3 kW · 1φ

MultiPlus-II 48/3000/35-32 230V GX AU (AS4777-2 2020)

3 kW · 1φ

MultiPlus-II 48/5000/70-50 230V

5 kW · 1φ

MultiPlus-II 48/5000/70-50 230V AU (AS4777-2 2020)

5 kW · 1φ

MultiPlus-II 48/5000/70-50 230V GX

5 kW · 1φ

View all Victron Energy BV inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?