Hybrid inverter · Sungrow · CEC approved November 2026

Sungrow SH3.0RS

CEC listing: SH3.0RS (AS4777-2 2020)

A 3 kW single-phase hybrid inverter that is battery-ready.

Rated power
3kW
How much solar it can run at once
Battery-ready
Yes
A battery plugs straight in
Feed-in credits (DEBS)
Yes
DEBS pays for exports only when the inverter is 5 kW or less

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3kW
How much solar it can turn into usable power at once
Max efficiency
97.4%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Sungrow Power Supply Co Ltd stands behind it

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
17 Nov 2026
Approval expiry
17 Sept 2029
Status
Active
Listed for STCs
Yes

About Sungrow

Years on the CEC list
5 years
Australian office
Yes
Category
Premium
CEC-approved inverters
49
CEC-approved batteries
19
View full profile →

Documents

WA compliance

Synergy's list
Not listed
Remote management
No record

This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.

Australian office

Has local presence

5 years on the CEC list

Perth performance

Estimate for a full-size array on this inverter

Daily yield
12.8 kWh
Annual yield
4,654 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

Full datasheet

Every figure on file for the Sungrow SH3.0RS, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power3 kW
Efficiency
Max efficiency97.4%
European efficiency97%
Physical
Weight18.5 kg
IP ratingIP65
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker32 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

How it compares

The Sungrow SH3.0RS against the closest-power inverters from other brands.

Specification
Rated power?3 kW3 kW3 kW
Max efficiency?97.4%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

10-year inverter warranty

Sungrow SH3.0RS

This warranty covers defects for 10 years, requires accredited installation, and excludes tampering. Claims can be submitted via the manufacturer’s website.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Tampering, non-accredited installation, or modifications void the warranty.
Environment limits
Non-compliant operating environments including salt spray and extreme temperatures (above 60°C) may void warranty.

Fault & error codes — Sungrow SH3.0RS

From the install manual

22 documented

Showing 22 of 22. The official install manual is the authoritative source — always confirm before acting.

  • 002,003,014criticalCall your installer
    Manual (PDF)

    Grid overvoltage

    Likely cause
    Inverter will reconnect to grid after recovery. Frequent occurrences may indicate voltage issues.
    What to do
    Measure grid voltage, contact local utility if it exceeds limits, check App for parameters, and inspect AC cable.
  • 028criticalCall your installer
    Manual (PDF)

    PV reverse connection fault

    Likely cause
    Reverse polarity in the PV string.
    What to do
    Check whether the corresponding string is of reverse polarity, disconnect the DC switch and adjust the polarity.
  • 028,029criticalCall your installer
    Manual (PDF)

    PV reverse connection fault

    Likely cause
    Indicates reverse polarity in the PV string.
    What to do
    Check polarity and adjust if necessary, preferably when solar radiation is low.
  • 088criticalCall your installer
    Manual (PDF)

    Arc fault

    Likely cause
    Damaged connectors or wiring
    What to do
    Disconnect DC inputs and check cables. Take corrective measures. Contact SUNGROW if persists.
  • 9088criticalCall your installer
    Manual (PDF)

    Arc fault

    Likely cause
    Indicates potential damage to DC cables or poor connections.
    What to do
    Check DC cables and components, remove fault via App if necessary.
  • 9716criticalCall your installer
    Manual (PDF)

    Battery polarity reversed

    Likely cause
    Indicates incorrect battery connection.
    What to do
    Correct battery polarity immediately; contact installer if problems persist.
  • 002warningCall your installer
    Manual (PDF)

    Grid overvoltage

    Likely cause
    Voltage exceeds specified limits
    What to do
    Measure the grid voltage and contact local utility if necessary. Check protection parameters and AC cable connections.
  • 003warningCall your installer
    Manual (PDF)

    Grid overvoltage

    Likely cause
    Voltage exceeds specified limits
    What to do
    Measure the grid voltage and contact local utility if necessary. Check protection parameters and AC cable connections.
  • 004warningCall your installer
    Manual (PDF)

    Grid undervoltage

    Likely cause
    Voltage falls below specified limits
    What to do
    Measure the grid voltage and contact local utility if necessary. Check protection parameters and AC cable connections.
  • 008warningCall your installer
    Manual (PDF)

    Grid overfrequency

    Likely cause
    Frequency exceeds specified limits
    What to do
    Measure the grid frequency and contact local utility if necessary. Check protection parameters.
  • 009warningCall your installer
    Manual (PDF)

    Grid underfrequency

    Likely cause
    Frequency falls below specified limits
    What to do
    Measure the grid frequency and contact local utility if necessary. Check protection parameters.
  • 012warningCall your installer
    Manual (PDF)

    Overhigh leakage current

    Likely cause
    Environmental conditions or wiring issues
    What to do
    Check AC and DC cables for insulation and environmental factors. Contact SUNGROW if persists.
  • 013warningCall your installer
    Manual (PDF)

    Grid abnormal

    Likely cause
    Inverter will reconnect after recovery. Frequent issues may indicate grid problems.
    What to do
    Measure grid frequency and consult local utility if necessary, check App parameters.
  • 038,041,048,052,064-067,100,105,107,113,200-202,303,304,308,312,315,316,600,605,612,616,620warningCall your installer
    Manual (PDF)

    System fault

    Likely cause
    Wait for inverter recovery; possible restart required.
    What to do
    Disconnect AC and DC switches, reconnect after 15 minutes. Contact installer if the alarm persists.
  • 039warningCall your installer
    Manual (PDF)

    Low insulation resistance

    Likely cause
    Faulty insulation at PV cables
    What to do
    Check insulation resistance and ensure cables are not damaged. Contact SUNGROW if persists.
  • 106warningCall your installer
    Manual (PDF)

    Grounding cable fault

    Likely cause
    Check AC cable connections and ground cable insulation.
    What to do
    Inspect connections and cables; contact installer if issues remain.
  • 214warningCall your installer
    Manual (PDF)

    Battery communication error

    Likely cause
    Issue with battery connection
    What to do
    Check battery connections and communication cable. Reinstall if necessary.
  • 9075warningCall your installer
    Manual (PDF)

    Parallel communication alarm

    Likely cause
    Communication cable or wiring issue.
    What to do
    Examine communication connections and reinstall cables as required.
  • 932-935,937,939,964warningCall your installer
    Manual (PDF)

    Battery alarm

    Likely cause
    Automatic recovery by battery; check for underlying issues.
    What to do
    Assess battery conditions and parameters; contact manufacturer or installer if issues continue.
  • 9714warningCall your installer
    Manual (PDF)

    BMS communication error

    Likely cause
    Battery communication issue due to polarity errors.
    What to do
    Check battery connections and contacts, adjust if necessary.
  • 010infoCall your installer
    Manual (PDF)

    Grid Power Outage

    Likely cause
    Power disruption from the grid
    What to do
    Check grid power reliability and ensure AC cable connections are secured.
  • 071,072,503-506,513,900,901infoCall your installer
    Manual (PDF)

    System alarm

    Likely cause
    Inverter functioning normally despite alarm.
    What to do
    Check connections and environment; contact installer if necessary.

More Sungrow inverters

View all Sungrow inverters

More from Sungrow

Other CEC-approved products from Sungrow available in Australia.

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.