Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SolaX Power
  4. X3-MIC-3K-G2

Solar inverter · SolaX Power · CEC approved August 2025

SolaX Power X3-MIC-3K-G2

CEC listing: X3-MIC-3K-G2 (AS4777-2 2020)

A 3 kW three-phase solar inverter.

Rated power
3kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

X3-MIC-3K-G2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3kW
How much solar it can turn into usable power at once
Max efficiency
98.3%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
10yr
How long SolaX Power Network Technology (Zhe jiang) Co Ltd stands behind it

Full datasheet

Every figure on file for the SolaX Power X3-MIC-3K-G2, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power3 kW
Efficiency
Max efficiency98.3%
European efficiency97.8%
DC input & MPPT
MPPT trackers2
Physical
Dimensions (H×W×D)434 × 342 × 156 mm
Weight15.5 kg
IP ratingIP66
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker20 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time10 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
15 Aug 2025
Approval expiry
30 May 2027
Status
Active
Listed for STCs
Yes

About SolaX Power

Years on the CEC list
5 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
137
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
12.8 kWh
Annual yield
4,654 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

5 years on the CEC list

How it compares

The SolaX Power X3-MIC-3K-G2 against the closest-power inverters from other brands.

Specification
SolaX Power X3-MIC-3K-G2SolaX Power
Energizer FORCE 3.0HSEnergizer
Energizer Force 3SEnergizer
Rated power?3 kW3 kW3 kW
Max efficiency?98.3%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesThree-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

SolaX Power X3-MIC-3K-G2

This warranty covers defects in material and workmanship for 10 years, with no coverage if tampered. Register your claim at https://www.solaxcloud.com/#/warranty.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, tampering.
Environment limits
Flooding, salt spray, temperatures above 60°C.
Read the official warranty document (PDF)

Fault & error codes — SolaX Power X3-MIC-3K-G2

From the install manual

29 documented

Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.

  • Arc FaultcriticalCall your installer
    Manual (PDF)

    Arc Fault

    Likely cause
    Check for potential arcs in the system
    What to do
    Wait for 5 minutes to check if the inverter is back to normal or perform manual clear or contact SolaX for help
  • ArcSelfTestFaultcriticalCall your installer
    Manual (PDF)

    Arc Self-check Fault

    Likely cause
    Check the arc detection function
    What to do
    Wait for 5 minutes to check if the inverter is back to normal or contact SolaX for help
  • DcInjOcpcriticalCall your installer
    Manual (PDF)

    DCI Overcurrent Protection Fault

    Likely cause
    Inverter operating under overcurrent conditions
    What to do
    Wait for a while to check if the inverter is back to normal or contact SolaX for help
  • GridFreqFaultcriticalCall your installer
    Manual (PDF)

    Grid Frequency Out of Range

    Likely cause
    Utility frequency abnormality
    What to do
    Wait for a while and the system will reconnect when the utility is back to normal or contact SolaX for help
  • GridLostFaultcriticalCall your installer
    Manual (PDF)

    Grid Lost Fault

    Likely cause
    Check if the mains cable is loose
    What to do
    Wait for a while and the system will reconnect when the utility is back to normal or contact SolaX for help
  • GridRelayFaultcriticalCall your installer
    Manual (PDF)

    Relay Fault

    Likely cause
    Check the grid connection
    What to do
    Restart the inverter or contact SolaX for help
  • GridVolt10MFaultcriticalCall your installer
    Manual (PDF)

    Grid Overvoltage for Ten Minutes Fault

    Likely cause
    Utility overvoltage
    What to do
    The system will reconnect when the utility is back to normal or contact SolaX for help
  • GridVoltFaultcriticalCall your installer
    Manual (PDF)

    Grid Voltage Out of Range

    Likely cause
    Check if the mains cable is loose
    What to do
    Wait for a while and the system will reconnect when the utility is back to normal or contact SolaX for help
  • HardLimitFaultcriticalCall your installer
    Manual (PDF)

    Hard Limit Fault

    Likely cause
    Exceeding the maximum output capacity set for the inverter
    What to do
    Wait for a while to check if the inverter is back to normal or contact SolaX for help
  • IsoFaultcriticalCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    Check the connections of the inverter
    What to do
    Contact SolaX for help
  • Meter FaultcriticalCall your installer
    Manual (PDF)

    Meter Fault

    Likely cause
    Check the connection of the meter
    What to do
    Contact SolaX for help
  • Mgr EEPROM FaultcriticalCall your installer
    Manual (PDF)

    ARM EEPROM Fault

    Likely cause
    Disconnect PV and grid, then reconnect
    What to do
    Contact SolaX for help
  • OtherDeviceFaultcriticalCall your installer
    Manual (PDF)

    Model Incorrectly Set Fault

    Likely cause
    Inverter has been set up incorrectly for the device connected
    What to do
    Contact SolaX for help
  • OverTempFaultcriticalCall your installer
    Manual (PDF)

    Over Temperature Fault

    Likely cause
    The inverter is overheating due to high ambient temperature
    What to do
    Check if the inverter and ambient temperature exceeds the operating range or contact SolaX for help
  • PvVoltFaultcriticalCall your installer
    Manual (PDF)

    PV Voltage Fault

    Likely cause
    Check whether the PV is overvoltage
    What to do
    Contact SolaX for help
  • TzFaultcriticalCall your installer
    Manual (PDF)

    Over Current Fault

    Likely cause
    Disconnect PV and restart the inverter
    What to do
    Wait for about 10 seconds to check if the inverter is back to normal or contact SolaX for help
  • AcTerminalOTPwarningCall your installer
    Manual (PDF)

    AC Terminal Overtemperature Fault

    Likely cause
    Check if the AC terminals are tightly connected
    What to do
    Check if the ambient temperature exceeds the operating range or contact SolaX for help
  • BusVoltFaultwarningCall your installer
    Manual (PDF)

    DC Bus Voltage Out of Normal Range

    Likely cause
    Check if the PV input voltage is within the operating range of the inverter
    What to do
    Disconnect PV wiring and reconnect or contact SolaX for help
  • EepromFaultwarningCall your installer
    Manual (PDF)

    DSP EEPROM Fault

    Likely cause
    Internal memory fault detected by the inverter
    What to do
    Disconnect PV wiring and reconnect or contact SolaX for help
  • InternalComFaultwarningCall your installer
    Manual (PDF)

    Internal Communication Fault

    Likely cause
    Inverter unable to communicate internally due to a fault
    What to do
    Restart the inverter to check if it is back to normal or contact SolaX for help
  • LowTempFaultwarningCall your installer
    Manual (PDF)

    Low Temperature Fault

    Likely cause
    The ambient temperature is too low
    What to do
    Contact SolaX for help
  • PowerTypeFaultwarningCall your installer
    Manual (PDF)

    Power Type Fault

    Likely cause
    Check the version of ARM and DSP
    What to do
    Contact SolaX for help
  • PvConnDirFaultwarningCall your installer
    Manual (PDF)

    PV Direction Fault

    Likely cause
    Check if the PV connections are correct
    What to do
    Contact SolaX for help
  • RcDeviceFaultwarningCall your installer
    Manual (PDF)

    Residual Current Device Fault

    Likely cause
    Inverter preventing operation due to RCD error
    What to do
    Restart the inverter or contact SolaX for help
  • ResidualOCPwarningCall your installer
    Manual (PDF)

    Overcurrent Protection Fault

    Likely cause
    Check the connections of the inverter
    What to do
    Wait for a while to check if the inverter is back to normal or contact SolaX for help
  • SW OCP FaultwarningCall your installer
    Manual (PDF)

    Software Overcurrent Protection Fault

    Likely cause
    Inverter software detecting overcurrent
    What to do
    Disconnect PV and grid, then reconnect or contact SolaX for help
  • Fan1 WarninginfoCall your installer
    Manual (PDF)

    External Fan 1 Abnormal Warning

    Likely cause
    Check if the fan is working
    What to do
    Contact SolaX for help
  • Fan2 WarninginfoCall your installer
    Manual (PDF)

    External Fan 2 Abnormal Warning

    Likely cause
    Check if the fan is working
    What to do
    Contact SolaX for help
  • FanFaultinfoCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    Check whether the fan is faulty or damaged
    What to do
    Contact SolaX for help

More SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

X3-HYB-4.0-P (AS4777-2 2020)

4 kW · 3φ

X3-MIC-4K-G2 (AS4777-2 2020)

4 kW · 3φ

X3-Hybrid-5.0-D (AS4777-2 2020)

4.999 kW · 3φ

X3-IES-5K (AS4777-2 2020)

4.999 kW · 3φ

X3-MIC-5K-G2 (AS4777-2 2020)

4.999 kW · 3φ

X3-HYB-5.0-P (AS4777-2 2020)

5 kW · 3φ

View all SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

More from SolaX Power

Other CEC-approved products from SolaX Power available in Australia.

SolaX Power Batteries

AELIO-B100-AU

90 kWh · LFP

T-BAT HS10.8

9.9 kWh · LFP

T-BAT HS14.4

13.3 kWh · LFP

T-BAT HS18.0

16.5 kWh · LFP

T-BAT HS21.6

19.8 kWh · LFP

T-BAT HS25.2

23.2 kWh · LFP

View all SolaX Power batteries
View full SolaX Power manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?