Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SolaX Power
  4. X3-HYB-15.0-P

Hybrid inverter · SolaX Power · CEC approved May 2026

SolaX Power X3-HYB-15.0-P

CEC listing: X3-HYB-15.0-P (AS4777-2 2020)

A 15 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
15kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

X3-HYB-15.0-P: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
15kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long SolaX Power Network Technology (Zhe jiang) Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the SolaX Power X3-HYB-15.0-P, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance120 mm
Side clearance300 mm
AC breaker20 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time2 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
1 May 2026
Approval expiry
1 May 2029
Status
Active
Listed for STCs
Yes

About SolaX Power

Years on the CEC list
5 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
137
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
63.8 kWh
Annual yield
23,269 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

5 years on the CEC list

How it compares

The SolaX Power X3-HYB-15.0-P against the closest-power inverters from other brands.

Specification
SolaX Power X3-HYB-15.0-PSolaX Power
Energizer Force 15.0HT+Energizer
Afore AF15K-THAfore
Rated power?15 kW15 kW15 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

SolaX Power X3-HYB-15.0-P

This warranty covers defects for 10 years, allowing two transfers. It excludes damage from unauthorized modifications. Claims can be made via the customer support contact information provided.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, tampering, or improper use voids the warranty.
Environment limits
Operation temperature limits (-35 ~ 60°C), derating above 45°C.
Read the official warranty document (PDF)

Fault & error codes — SolaX Power X3-HYB-15.0-P

From the install manual

73 documented

Showing 73 of 73. The official install manual is the authoritative source — always confirm before acting.

  • BE01criticalCall your installer
    Manual (PDF)

    BMS_Exter_Err

    Likely cause
    Battery error - external communication fault
    What to do
    Contact the battery supplier for help.
  • BE02criticalCall your installer
    Manual (PDF)

    BMS_InterErr

    Likely cause
    Battery error - internal communication fault
    What to do
    Contact the battery supplier for help.
  • BE03criticalCall your installer
    Manual (PDF)

    BMS_OverVolt

    Likely cause
    Over voltage in battery system
    What to do
    Contact the battery supplier for help.
  • BE04criticalCall your installer
    Manual (PDF)

    BMS_LowerVolt

    Likely cause
    Low voltage in battery system
    What to do
    Contact the battery supplier for help.
  • BE05criticalCall your installer
    Manual (PDF)

    BMS_ChargeOCP

    Likely cause
    Battery fault - over charge fault
    What to do
    Contact the battery supplier for help.
  • BE06criticalCall your installer
    Manual (PDF)

    DischargeOCP

    Likely cause
    Battery fault-discharge over current fault
    What to do
    Contact the battery supplier for help.
  • BE07criticalCall your installer
    Manual (PDF)

    BMS_TemHigh

    Likely cause
    Over temperature in battery system
    What to do
    Contact the battery supplier for help.
  • BE08criticalCall your installer
    Manual (PDF)

    BMS_TempLow

    Likely cause
    Battery temperature sensor malfunction
    What to do
    Contact the battery supplier for help.
  • BE09criticalCall your installer
    Manual (PDF)

    CellImbalance

    Likely cause
    Battery Unbalanced Fault
    What to do
    Contact the battery supplier for help.
  • BE10criticalCall your installer
    Manual (PDF)

    BMS_Hardware

    Likely cause
    Battery hardware protection fault
    What to do
    Contact the battery supplier for help.
  • BE11criticalCall your installer
    Manual (PDF)

    BMS_Circuit

    Likely cause
    Battery circuit fault
    What to do
    Restart the battery. Contact the battery supplier for help.
  • BE12criticalCall your installer
    Manual (PDF)

    BMS_ISO_Fault

    Likely cause
    Battery insulation fault
    What to do
    Check that the battery is properly grounded and restart the battery. Contact the battery supplier for help.
  • BE13criticalCall your installer
    Manual (PDF)

    BMS_VolSen

    Likely cause
    Battery voltage sensor fault
    What to do
    Contact the battery supplier for help.
  • BE14criticalCall your installer
    Manual (PDF)

    BMS_TempSen

    Likely cause
    Temperature sensor fault
    What to do
    Restart the battery. Contact the battery supplier for help.
  • BE15criticalCall your installer
    Manual (PDF)

    BMS_CurSen

    Likely cause
    Battery current sensor fault
    What to do
    Contact the battery supplier for help.
  • BE16criticalCall your installer
    Manual (PDF)

    BMS_Relay

    Likely cause
    Battery relay fault
    What to do
    Contact the battery supplier for help.
  • BE17criticalCall your installer
    Manual (PDF)

    TypeUnmatch

    Likely cause
    Battery type fault
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE18criticalCall your installer
    Manual (PDF)

    Ver Unmatch

    Likely cause
    Battery version mismatch fault
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE19criticalCall your installer
    Manual (PDF)

    MFR Unmatch

    Likely cause
    Battery manufacturer mismatch fault
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE20criticalCall your installer
    Manual (PDF)

    SW Unmatch

    Likely cause
    Battery hardware and software mismatch fault
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE21criticalCall your installer
    Manual (PDF)

    M&S Unmatch

    Likely cause
    Battery master slave control mismatch fault
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE22criticalCall your installer
    Manual (PDF)

    CR NORespond

    Likely cause
    Battery charging request no respond
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE23criticalCall your installer
    Manual (PDF)

    BMS_SW Protect

    Likely cause
    Battery slave software protection failure
    What to do
    Upgrade the battery BMS software. Contact the battery supplier for help.
  • BE24criticalCall your installer
    Manual (PDF)

    BMS_536 Fault

    Likely cause
    Battery discharge over current fault
    What to do
    Contact the battery supplier for help.
  • BE25criticalCall your installer
    Manual (PDF)

    BMS_SelfCheck

    Likely cause
    Over temperature in battery system
    What to do
    Contact the battery supplier for help.
  • BE26criticalCall your installer
    Manual (PDF)

    BMS_Tempdiff

    Likely cause
    Battery temperature sensor malfunction
    What to do
    Contact the battery supplier for help.
  • BE27criticalCall your installer
    Manual (PDF)

    BMS_BreakFault

    Likely cause
    Battery unbalanced fault
    What to do
    Contact the battery supplier for help.
  • BE28criticalCall your installer
    Manual (PDF)

    BMS_FlashFault

    Likely cause
    Battery hardware protection failure
    What to do
    Contact the battery supplier for help.
  • BE29criticalCall your installer
    Manual (PDF)

    BMS_Precharge

    Likely cause
    Battery precharge fault
    What to do
    Contact the battery supplier for help.
  • BE30criticalCall your installer
    Manual (PDF)

    AirSwitchBreaker

    Likely cause
    Battery air switch fault
    What to do
    Check if the battery breaker is off. Contact the battery supplier for help.
  • IE01criticalCall your installer
    Manual (PDF)

    TZ Protect Fault

    Likely cause
    Overcurrent fault
    What to do
    Wait for a while to check if you're back to normal. Disconnect PV+PV- and batteries, reconnect.
  • IE02criticalCall your installer
    Manual (PDF)

    Grid Lost Fault

    Likely cause
    Grid lost fault
    What to do
    Check the grid connection status.
  • IE03criticalCall your installer
    Manual (PDF)

    Grid Volt Fault

    Likely cause
    Power grid voltage overrun
    What to do
    Wait a moment, if the utility returns to normal, the system will reconnect.
  • IE04criticalCall your installer
    Manual (PDF)

    Grid Freq Fault

    Likely cause
    Grid overfrequency
    What to do
    Wait a moment, if the utility returns to normal, the system reconnects.
  • IE05criticalCall your installer
    Manual (PDF)

    PV Volt Fault

    Likely cause
    PV overvoltage
    What to do
    Check the output voltage of the PV panel.
  • IE06criticalCall your installer
    Manual (PDF)

    Bus Volt Fault

    Likely cause
    Voltage issue
    What to do
    Press the ESC key to restart the inverter.
  • IE07criticalCall your installer
    Manual (PDF)

    Bat Volt Fault

    Likely cause
    Battery voltage fault
    What to do
    Check if the battery input voltage is within normal range.
  • IE09criticalCall your installer
    Manual (PDF)

    DCI OCP Fault

    Likely cause
    DCI overcurrent protection fault
    What to do
    Wait for a while to check if it's back to normal.
  • IE10criticalCall your installer
    Manual (PDF)

    DCV OVP Fault

    Likely cause
    DCV EPS (Off-grid) overvoltage protection fault
    What to do
    Wait for a while to check if it's back to normal.
  • IE101criticalCall your installer
    Manual (PDF)

    Power Type Fault

    Likely cause
    Power type fault
    What to do
    Upgrade the software and press the ESC key to restart the inverter.
  • IE103criticalCall your installer
    Manual (PDF)

    Mgr EEPROM Fault

    Likely cause
    Manager EEPROM fault
    What to do
    Shut down photovoltaic battery and grid, reconnect.
  • IE11criticalCall your installer
    Manual (PDF)

    SW OCP Fault

    Likely cause
    Software detection of overcurrent fault
    What to do
    Wait for a while to check if it's back to normal. Shut down photovoltaic, battery and grid connections.
  • IE110criticalCall your installer
    Manual (PDF)

    Bypass Relay Fault

    Likely cause
    Bypass relay fault
    What to do
    Press the ESC key to restart the inverter.
  • IE111criticalCall your installer
    Manual (PDF)

    ARM Para Com Fault

    Likely cause
    ARM parameter communication fault
    What to do
    Check that the communication cables of inverters are well connected and the baud rate of COMM setting of inverters are the same.
  • IE12criticalCall your installer
    Manual (PDF)

    RC OCP Fault

    Likely cause
    Overcurrent protection fault
    What to do
    Check the impedance of DC input and AC output. Wait for a while to check if it's back to normal.
  • IE13criticalCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    Insulation fault
    What to do
    Please check the wire insulation for damage. Wait for a while to check if it's back to normal.
  • IE15criticalCall your installer
    Manual (PDF)

    Bat Con Dir Fault

    Likely cause
    Battery direction fault
    What to do
    Check if the battery cables are connected in the opposite direction.
  • IE16criticalCall your installer
    Manual (PDF)

    EPS Overload Fault

    Likely cause
    EPS(Off-grid) overload fault
    What to do
    Shutdown the high-power device and press the ESC key to restart the inverter.
  • IE17criticalCall your installer
    Manual (PDF)

    Overload Fault

    Likely cause
    On-grid mode overload fault
    What to do
    Shutdown the high-power device and press the ESC key to restart the inverter.
  • IE19criticalCall your installer
    Manual (PDF)

    BMS Lost

    Likely cause
    Battery communication lost
    What to do
    Check that the communication cable between the battery and the inverter are properly connected.
  • IE25criticalCall your installer
    Manual (PDF)

    InterCom Fault

    Likely cause
    Internal communication fault
    What to do
    Restart the inverter.
  • IE26criticalCall your installer
    Manual (PDF)

    INV EEPROM Fault

    Likely cause
    Inverter EEPROM fault
    What to do
    Shut down photovoltaic, battery and grid, reconnect.
  • IE27criticalCall your installer
    Manual (PDF)

    RCD Fault

    Likely cause
    Residual current device fault
    What to do
    Check the impedance of DC input and AC output. Disconnect PV+, PV- and batteries, reconnect.
  • IE28criticalCall your installer
    Manual (PDF)

    Grid Relay Fault

    Likely cause
    Electrical relay fault
    What to do
    Disconnect PV+, PV-, grid and batteries and reconnect.
  • IE29criticalCall your installer
    Manual (PDF)

    EPS(Off-grid) Relay Fault

    Likely cause
    EPS(Off-grid) relay fault
    What to do
    Disconnect PV+, PV-, grid and batteries and reconnect.
  • IE30criticalCall your installer
    Manual (PDF)

    PV ConnDir Fault

    Likely cause
    PV direction fault
    What to do
    Check if the PV input cables are connected in the opposite direction.
  • IE31criticalCall your installer
    Manual (PDF)

    Battery Relay Fault

    Likely cause
    Charge relay fault
    What to do
    Press the ESC key to restart the inverter.
  • IE32criticalCall your installer
    Manual (PDF)

    Earth Relay Fault

    Likely cause
    EPS(Off-grid) earth relay fault
    What to do
    Press the ESC key to restart the inverter.
  • IE33criticalCall your installer
    Manual (PDF)

    Parallel Fault

    Likely cause
    Parallel fault
    What to do
    Check the communication and earth cable connection and matching resistor settings.
  • IE08warningCall your installer
    Manual (PDF)

    AC10mins Volt

    Likely cause
    Grid voltage out of range in the last 10 minutes
    What to do
    The system will return to normal if the grid returns to normal.
  • IE102warningCall your installer
    Manual (PDF)

    Port OC Warning

    Likely cause
    EPS(Off-grid) port overcurrent fault
    What to do
    Check if the EPS(Off-grid) load exceeds the system requirements, and press the ESC key to restart the inverter.
  • IE105warningCall your installer
    Manual (PDF)

    NTC Sample Invalid

    Likely cause
    NTC invalid
    What to do
    Make sure the NTC is properly connected and the NTC is in good condition.
  • IE106warningCall your installer
    Manual (PDF)

    Bat Temp Low

    Likely cause
    Battery temperature low
    What to do
    Check the battery installation environment to ensure good heat dissipation.
  • IE107warningCall your installer
    Manual (PDF)

    Bat Temp High

    Likely cause
    Battery temperature high
    What to do
    Check the battery installation environment to ensure good heat dissipation.
  • IE109warningCall your installer
    Manual (PDF)

    Meter Fault

    Likely cause
    Meter fault
    What to do
    Check if the meter is normal and is compatible with the inverter.
  • IE112warningCall your installer
    Manual (PDF)

    FAN1 Fault

    Likely cause
    FAN1 fault
    What to do
    Check if the foreign objects stuck in the fan.
  • IE113warningCall your installer
    Manual (PDF)

    FAN2 Fault

    Likely cause
    FAN2 fault
    What to do
    Check if the foreign objects stuck in the fan.
  • IE14warningCall your installer
    Manual (PDF)

    Temp Over Fault

    Likely cause
    Temperature out of range
    What to do
    Check if the ambient temperature exceeds the limit.
  • IE18warningCall your installer
    Manual (PDF)

    BatPowerLow

    Likely cause
    Battery power low
    What to do
    Shutdown the high-power device and press the ESC key to restart the inverter. Charge the battery to a level higher than the protection capacity or protection voltage.
  • IE20warningCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    Fan fault
    What to do
    Check for any foreign matter that may have caused the fan not to function properly.
  • IE21warningCall your installer
    Manual (PDF)

    Low Temp Fault

    Likely cause
    Low temperature fault
    What to do
    Check if the ambient temperature is too low.
  • IE36warningCall your installer
    Manual (PDF)

    Hard Limit Fault

    Likely cause
    Hard Limit fault
    What to do
    Check the power value set in the Hard Limit setting, increase the value larger if needed.
  • IE37warningCall your installer
    Manual (PDF)

    CT Meter Con Fault

    Likely cause
    CT Meter Con fault
    What to do
    Check if the CT or meter is well connected.

More SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

X3-Hybrid-15.0-D (AS4777-2 2020)

14.999 kW · 3φ

X3-IES-15K (AS4777-2 2020)

14.999 kW · 3φ

X3-MIC-15K-G2 (AS4777-2 2020)

14.999 kW · 3φ

X3-PRO-15K-G2 (AS4777-2 2020)

14.999 kW · 3φ

X3-ULT-15K (AS4777-2 2020)

14.999 kW · 3φ

X3-ULT-15KP (AS4777-2 2020)

14.999 kW · 3φ

View all SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

More from SolaX Power

Other CEC-approved products from SolaX Power available in Australia.

SolaX Power Batteries

AELIO-B100-AU

90 kWh · LFP

T-BAT HS10.8

9.9 kWh · LFP

T-BAT HS14.4

13.3 kWh · LFP

T-BAT HS18.0

16.5 kWh · LFP

T-BAT HS21.6

19.8 kWh · LFP

T-BAT HS25.2

23.2 kWh · LFP

View all SolaX Power batteries
View full SolaX Power manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?