Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sieyuan Electric
  4. SiH-5kW-SH

Hybrid inverter · Sieyuan Electric · CEC approved May 2023

Sieyuan Electric SiH-5kW-SH

CEC listing: SiH-5kW-SH (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SiH-5kW-SH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Sieyuan Electric Co Ltd stands behind it

Full datasheet

Every figure on file for the Sieyuan Electric SiH-5kW-SH, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Efficiency
Max efficiency98%
European efficiency97.2%
Physical
Dimensions (H×W×D)550 × 450 × 185 mm
Weight31 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker25 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time10 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
3 May 2023
Approval expiry
29 Dec 2026
Status
Active
Listed for STCs
Yes

About Sieyuan Electric

Years on the CEC list
3 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
2
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

3 years on the CEC list

How it compares

The Sieyuan Electric SiH-5kW-SH against the closest-power inverters from other brands.

Specification
Sieyuan Electric SiH-5kW-SHSieyuan Electric
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty terms and installation guide and user manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Sieyuan Electric SiH-5kW-SH

This warranty covers core components for 10 years. Major exclusions include damages from improper installation. To make a claim, contact support with your proof of purchase.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, or tampering.
Environment limits
None specified.
Read the official warranty document (PDF)

Fault & error codes — Sieyuan Electric SiH-5kW-SH

From the install manual

16 documented

Showing 16 of 16. The official install manual is the authoritative source — always confirm before acting.

  • 100criticalCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Similar to code 112, indicates high grid voltage.
    What to do
    Check the protection parameters through the SOLARMAN Smart App.
  • 101criticalCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage exceeds limits set by the inverter.
    What to do
    With approval from the local power operator, modify the voltage protection value.
  • 102criticalCall your installer
    Manual (PDF)

    Grid Undervoltage

    Likely cause
    Grid voltage is below the set threshold.
    What to do
    With approval for the local power operator, modify the voltage protection value.
  • 106criticalCall your installer
    Manual (PDF)

    Grid Overfrequency

    Likely cause
    Grid frequency exceeds the set limit.
    What to do
    Measure the actual grid frequency. Contact the local power company for a solution if frequency is high.
  • 107criticalCall your installer
    Manual (PDF)

    Grid Underfrequency

    Likely cause
    Grid frequency is below the set limit.
    What to do
    Measure the actual grid frequency. Contact the local power company for a solution if frequency is low.
  • 112criticalCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage is higher than the set value.
    What to do
    Measure the actual grid voltage. Contact the local power company for a solution if the grid voltage is high.
  • 110warningCall your installer
    Manual (PDF)

    Leakage Current Fault

    Likely cause
    Possible insufficient sunlight or humid environment leading to leakage.
    What to do
    Check insulation of AC and DC cables. If fault persists, contact Swatten.
  • 122warningCall your installer
    Manual (PDF)

    Ground Fault

    Likely cause
    Incorrect AC cable connection or insulation issue.
    What to do
    Check AC cable connections and insulation.
  • 129warningCall your installer
    Manual (PDF)

    EPS Load Overload

    Likely cause
    Load connected to the Off-grid port exceeds the maximum limit.
    What to do
    Reduce power of loads connected to the Off-grid port or remove some loads.
  • 209warningCall your installer
    Manual (PDF)

    Photovoltaic Reverse Connection Fault

    Likely cause
    PV string is connected in reverse polarity.
    What to do
    Check PV string connection for proper polarity.
  • 210warningCall your installer
    Manual (PDF)

    Photovoltaic Reverse Connection Fault

    Likely cause
    Similar to code 209 but for different PV inputs.
    What to do
    Check PV string connection for proper polarity.
  • 501warningCall your installer
    Manual (PDF)

    Environmental Overtemperature

    Likely cause
    High ambient temperature affecting inverter operation.
    What to do
    Ensure the inverter is in a well-ventilated area and not exposed to direct sunlight.
  • 503warningCall your installer
    Manual (PDF)

    Insulation Fault

    Likely cause
    Ground or DC cable insulation resistance issues.
    What to do
    Check insulation of ground and DC cables.
  • 516warningCall your installer
    Manual (PDF)

    Off-grid Abnormality

    Likely cause
    EPS is overloaded beyond capacity.
    What to do
    Confirm if the off-grid is overloaded and reduce load to below limits.
  • 803warningCall your installer
    Manual (PDF)

    Meter Communication Abnormality

    Likely cause
    Issue with communication between inverter and meter.
    What to do
    Check wiring and communication settings.
  • 830warningCall your installer
    Manual (PDF)

    Meter Communication Abnormality

    Likely cause
    Similar to the code above, indicating communication issue.
    What to do
    Check communication lines and connections.

More Sieyuan Electric Co Ltd inverters

SiH-6kW-SH (AS4777-2 2020)

6 kW · 1φ

View all Sieyuan Electric Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?