Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. KSTAR
  4. KAC20DP2

Hybrid inverter · KSTAR · CEC approved September 2026

KSTAR KAC20DP2

CEC listing: KAC20DP2 (AS4777-2 2020)

A 20 kW three-phase hybrid inverter that is battery-ready.

Rated power
20kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

KAC20DP2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
20kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Shenzhen Kstar New Energy Company Limited stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the KSTAR KAC20DP2, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Top clearance500 mm
Side clearance300 mm
AC breaker20 A
Cable gauge10 mm²
Earthing methodMEN
DNSP pre-approvalYes
Estimated install time4 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
3 Sept 2026
Approval expiry
3 Sept 2029
Status
Active
Listed for STCs
Yes

About KSTAR

Years on the CEC list
4 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
19
CEC-approved batteries
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

4 years on the CEC list

How it compares

The KSTAR KAC20DP2 against the closest-power inverters from other brands.

Specification
KSTAR KAC20DP2KSTAR
Afore AF20K-THAfore
Solplanet ASW020K-THSolplanet
Rated power?20 kW20 kW20 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

KSTAR KAC20DP2

KSTAR offers a 5-year warranty covering defects in materials and workmanship. It excludes damage from improper installation or climate effects. Claims can be made via KSTAR’s website or email.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, improper maintenance, incorrect usage.
Environment limits
Rust due to harsh conditions, exposure to saltwater or aggressive environments.
Read the official warranty document (PDF)

Fault & error codes — KSTAR KAC20DP2

From the install manual

20 documented

Showing 20 of 20. The official install manual is the authoritative source — always confirm before acting.

  • F07criticalCall your installer
    Manual (PDF)

    Insulation impedance Fault

    Likely cause
    Low impedance between PV+/PV- to ground
    What to do
    Disconnect PV input and measure impedance to ground.
  • F12critical
    Manual (PDF)

    Ambient Temperature Over

    Likely cause
    Excessive environmental temperature
    What to do
    Disconnect PV input and cool down the inverter.
  • F13critical
    Manual (PDF)

    Heatsink Temperature High

    Likely cause
    High operating temperature
    What to do
    Disconnect PV input and cool down the inverter.
  • F14criticalCall your installer
    Manual (PDF)

    AC Relay Fault

    Likely cause
    Faulty AC relay
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F20criticalCall your installer
    Manual (PDF)

    Leakage Current High

    Likely cause
    High leakage current detected
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F21criticalCall your installer
    Manual (PDF)

    Leakage Current Self-Checking Failure

    Likely cause
    Leakage current check failed
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F22criticalCall your installer
    Manual (PDF)

    Consistency Voltage Fault

    Likely cause
    Voltage inconsistency detected
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F23criticalCall your installer
    Manual (PDF)

    Consistency Frequency Fault

    Likely cause
    Frequency inconsistency detected
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F24criticalCall your installer
    Manual (PDF)

    DSP Operation Fault

    Likely cause
    Fault in DSP operation
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F32criticalCall your installer
    Manual (PDF)

    DSP communication Lost

    Likely cause
    Communication interruption
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F00-F03warning
    Manual (PDF)

    AC voltage & frequency are too high or too low

    Likely cause
    Input voltage not compliant with safety standard
    What to do
    Check mains voltage and AC output line connection. Disconnect PV input and restart the inverter if needed.
  • F04-F05warning
    Manual (PDF)

    Bus voltage is too high or too low

    Likely cause
    Input mode setting issue
    What to do
    Check input mode settings and restart the inverter if needed.
  • F06warning
    Manual (PDF)

    Bus voltage is unbalanced

    Likely cause
    Input mode issue
    What to do
    Check input mode settings and restart the inverter if needed.
  • F08warning
    Manual (PDF)

    Input Current High

    Likely cause
    Incorrect input mode setting
    What to do
    Check input mode settings and restart the inverter if needed.
  • F09warning
    Manual (PDF)

    Hardware Current High

    Likely cause
    Inverter needs restart due to high current
    What to do
    Disconnect PV input and restart the inverter after a few minutes.
  • F10warning
    Manual (PDF)

    Inverter Current High

    Likely cause
    High current detected in inverter
    What to do
    Disconnect PV input and restart the inverter after a few minutes.
  • F11warning
    Manual (PDF)

    Inverter DC Current high

    Likely cause
    High DC current detected
    What to do
    Disconnect PV input and restart the inverter after a few minutes.
  • F15warning
    Manual (PDF)

    PV Input Voltage Low

    Likely cause
    PV input inactive in parallel mode
    What to do
    Check PV input configuration and restart the inverter.
  • F18warning
    Manual (PDF)

    SPI communication Fault

    Likely cause
    Communication issue
    What to do
    Disconnect PV input and restart the inverter if needed.
  • F16info
    Manual (PDF)

    Remote Off

    Likely cause
    Inverter is in remote OFF status
    What to do
    Turn inverter ON through monitoring software.

More Shenzhen Kstar New Energy Company Limited inverters

KAC25DP2 (AS4777-2 2020)

25 kW · 3φ

E12KT-D22 (AS4777-2 2020)

12 kW · 3φ

KAC29.9DP2 (AS4777-2 2020)

29.9 kW · 3φ

E10KT-D22 (AS4777-2 2020)

10 kW · 3φ

KAC30DP2 (AS4777-2 2020)

30 kW · 3φ

E8KT-D22 (AS4777-2 2020)

8 kW · 3φ

View all Shenzhen Kstar New Energy Company Limited inverters

More from KSTAR

Other CEC-approved products from KSTAR available in Australia.

KSTAR Batteries

BC100DE2A

98.47 kWh · LFP

BC100DE2A-AU

98 kWh · LFP

BC107DE2

96.768 kWh · LFP

BC120DE2A

118.164 kWh · LFP

BC125DE2

122.93 kWh · LFP

BC140DE2A

137.86 kWh · LFP

View all KSTAR batteries
View full KSTAR manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?