Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. KSTAR
  4. E12KT-D22

Hybrid inverter · KSTAR · CEC approved June 2026

KSTAR E12KT-D22

CEC listing: E12KT-D22 (AS4777-2 2020)

A 12 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
12kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

E12KT-D22: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
12kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Shenzhen Kstar New Energy Company Limited stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the KSTAR E12KT-D22, by section.

Full datasheet, by section
SpecificationValue
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance500 mm
Side clearance500 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
1 June 2026
Approval expiry
1 June 2029
Status
Active
Listed for STCs
Yes

About KSTAR

Years on the CEC list
4 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
19
CEC-approved batteries
42
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
51.0 kWh
Annual yield
18,615 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The KSTAR E12KT-D22 against the closest-power inverters from other brands.

Specification
KSTAR E12KT-D22KSTAR
Energizer Force 12.0HT+Energizer
Afore AF12K-THAfore
Rated power?12 kW12 kW12 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty terms and installation guide and user manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

KSTAR E12KT-D22

This warranty covers defects for 10 years. Important exclusions include improper installation. To claim, contact our support team with your purchase invoice.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Voids if modified, installed by non-accredited technicians, or tampered with.
Environment limits
Does not cover damages from extreme humidity, salt spray, or temperatures exceeding 60°C.
Read the official warranty document (PDF)

Fault & error codes — KSTAR E12KT-D22

From the install manual

8 documented

Showing 8 of 8. The official install manual is the authoritative source — always confirm before acting.

  • F01criticalCall your installer
    Manual (PDF)

    INV Volt Short: The inverter output is shorted.

    Likely cause
    A short circuit in the inverter's output voltage.
    What to do
    Disconnect all power sources, shut down the inverter and battery packs, disconnect the load, then power on and restart.
  • F03criticalCall your installer
    Manual (PDF)

    System Always Fault

    Likely cause
    The inverter cannot operate normally due to exceeding the rated output power.
    What to do
    Remove all loads from the inverter to check if it can work normally. If it continues to fail, contact Customer Service.
  • F06criticalCall your installer
    Manual (PDF)

    Bus Short Circuit: The bus is shorted.

    Likely cause
    A short circuit present on the bus.
    What to do
    Restart the inverter. If the issue persists, contact Customer Service for further inspection.
  • F07criticalCall your installer
    Manual (PDF)

    PV ISO Under Fault: The insulation resistance of a PV panel is low.

    Likely cause
    Poor insulation or grounding of the PV strings.
    What to do
    Check ground connection and resistance of PV inputs, ensure proper wiring to maintain insulation. If the issue persists, contact Customer Service.
  • F00warning
    Manual (PDF)

    Soft Time Out: Soft-start timeout.

    Likely cause
    A delay occurred during the soft-start phase that exceeded the timeout period.
    What to do
    Restart the inverter and wait until it runs correctly. If the code persists, contact Customer Service.
  • F02warningCall your installer
    Manual (PDF)

    GFCI Sensor Fault: A failure occurs to the Ground Fault Circuit Interrupter (GFCI) sensor.

    Likely cause
    A fault in the GFCI sensor.
    What to do
    Disconnect all power sources, restart the inverter and wait until it runs correctly. If it persists, contact Customer Service.
  • F04warning
    Manual (PDF)

    Bus Volt Low: The bus voltage is low.

    Likely cause
    The input mode settings are not properly configured or low input voltage.
    What to do
    Check input mode settings and restart the inverter. If the issue persists, contact Customer Service.
  • F05warning
    Manual (PDF)

    Bus Volt High: The bus voltage is high.

    Likely cause
    Voltage level exceeds acceptable parameters.
    What to do
    Check the input voltage and restart. If it remains high, contact Customer Service.

More Shenzhen Kstar New Energy Company Limited inverters

E10KT-D22 (AS4777-2 2020)

10 kW · 3φ

E8KT-D22 (AS4777-2 2020)

8 kW · 3φ

E6KT-D22 (AS4777-2 2020)

6 kW · 3φ

E5KT-D22 (AS4777-2 2020)

5 kW · 3φ

E4KT-D22 (AS4777-2 2020)

4 kW · 3φ

KAC20DP2 (AS4777-2 2020)

20 kW · 3φ

View all Shenzhen Kstar New Energy Company Limited inverters

More from KSTAR

Other CEC-approved products from KSTAR available in Australia.

KSTAR Batteries

BC100DE2A

98.47 kWh · LFP

BC100DE2A-AU

98 kWh · LFP

BC107DE2

96.768 kWh · LFP

BC120DE2A

118.164 kWh · LFP

BC125DE2

122.93 kWh · LFP

BC140DE2A

137.86 kWh · LFP

View all KSTAR batteries
View full KSTAR manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?