Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Growatt
  4. MOD 10KTL3-XA

Battery inverter · Growatt · CEC approval expired

Growatt MOD 10KTL3-XA

CEC listing: MOD 10KTL3-XA (AS4777-2 2020)

A 10 kW three-phase battery inverter.

Rated power
10kWHow much solar it can run at once: a large roof
Battery-ready
YesBattery inverter: it runs the battery, alongside your solar inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a battery inverter: it runs a battery, and pairs with a separate solar inverter.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
10kW
How much solar it can turn into usable power at once
Max efficiency
98.6%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Battery
Runs a battery; pairs with a separate solar inverter
Warranty
3yr
How long Shenzhen Growatt New Energy Co Ltd stands behind it

Full datasheet

Every figure on file for the Growatt MOD 10KTL3-XA, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.6%

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
16 Aug 2023
Approval expiry
16 Aug 2026
Status
Not listed
Listed for STCs
No (not listed)

About Growatt

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
132
CEC-approved batteries
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
42.5 kWh
Annual yield
15,513 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.growatt.com.au
12 years on the CEC list

How it compares

The Growatt MOD 10KTL3-XA against the closest-power inverters from other brands.

Specification
Growatt MOD 10KTL3-XAGrowatt
Energizer Force 10.0HS+Energizer
Energizer Force 10.0HT+Energizer
Rated power?10 kW10 kW10 kW
Max efficiency?98.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeBatteryHybridHybrid
Battery readyYesYesYes
Warranty3 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab

3-year inverter warranty

Growatt MOD 10KTL3-XA

This warranty covers defects in materials and workmanship for three years. Important exclusions include warranty voids due to improper installation or any modifications made to the product. To make a claim, please contact customer service with your warranty information.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Void warranty for non-accredited installation or modification.
Environment limits
None stated
Read the official warranty document (PDF)

Fault & error codes — Growatt MOD 10KTL3-XA

From the install manual

5 documented

Showing 5 of 5. The official install manual is the authoritative source — always confirm before acting.

  • Error 200criticalCall your installer
    Manual (PDF)

    AFCI Fault

    Likely cause
    Check the panel terminal for issues related to electric arcs.
    What to do
    After shutdown, check the panel terminal. Restart inverter. If error message still exists, contact manufacturer.
  • Error 201criticalCall your installer
    Manual (PDF)

    Leakage current too high.

    Likely cause
    Leakage current detected exceeds safe levels.
    What to do
    Restart inverter. If error message still exists, contact manufacturer.
  • Error 202criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value.

    Likely cause
    DC voltage above specified limits.
    What to do
    Immediately disconnect the DC switch and check voltage. If fault code still exists after restoration, contact manufacturer.
  • Error 203criticalCall your installer
    Manual (PDF)

    PV isolation Low

    Likely cause
    Grounding issue with the panel shell.
    What to do
    After shutdown, check whether the panel shell is reliably grounded. If error message still exists, contact manufacturer.
  • Error 303criticalCall your installer
    Manual (PDF)

    NE abnormal

    Likely cause
    PE line may be poorly connected.
    What to do
    Check PE to ensure good contact. If error message still exists, contact manufacturer.

More Shenzhen Growatt New Energy Co Ltd inverters

MOD 10KTL3-XH (AS4777-2 2020)

10 kW · 3φ

MID 10KTL3-XH (AS4777-2 2020)

9.99 kW · 3φ

MOD 9000TL3-XA (AS4777-2 2020)

9 kW · 3φ

MOD 9000TL3-XH (AS4777-2 2020)

9 kW · 3φ

MID 11KTL3-XH (AS4777-2 2020)

11 kW · 3φ

MOD 8000TL3-XA (AS4777-2 2020)

8 kW · 3φ

View all Shenzhen Growatt New Energy Co Ltd inverters

More from Growatt

Other CEC-approved products from Growatt available in Australia.

Growatt Batteries

ALP 10.0L-E1

10 kWh · LFP

ALP 10.0L-E2

10 kWh · LFP

ALP 15.0L-E1

15 kWh · LFP

ALP 15.0L-E2

15 kWh · LFP

ALP 20.0L-E1

20 kWh · LFP

ALP 20.0L-E2

20 kWh · LFP

View all Growatt batteries
View full Growatt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?