Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Growatt
  4. MID 20KTL3-XH

Solar inverter · Growatt · CEC approved April 2025

Growatt MID 20KTL3-XH

CEC listing: MID 20KTL3-XH (AS4777-2 2020)

A 20 kW three-phase solar inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
20kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

MID 20KTL3-XH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
20kW
How much solar it can turn into usable power at once
Max efficiency
98.8%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Solar
Runs solar only
Warranty
5yr
How long Shenzhen Growatt New Energy Co Ltd stands behind it

Full datasheet

Every figure on file for the Growatt MID 20KTL3-XH, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power11 kW
Efficiency
Max efficiency98.75%
European efficiency98.5%
Physical
IP ratingIP66
Rebate eligibility
Listed for battery storage on Synergy's listYes

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
22 Apr 2025
Approval expiry
22 Apr 2028
Status
Active
Listed for STCs
Yes

About Growatt

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
132
CEC-approved batteries
50
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Australian office

Has local presence

Website

www.growatt.com.au
12 years on the CEC list

How it compares

The Growatt MID 20KTL3-XH against the closest-power inverters from other brands.

Specification
Growatt MID 20KTL3-XHGrowatt
Afore AF20K-THAfore
Solplanet ASW020K-THSolplanet
Rated power?20 kW20 kW20 kW
Max efficiency?98.8%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Growatt MID 20KTL3-XH

This warranty covers defects in materials and workmanship for five years. Important exclusions include damage from unqualified installation and modifications; the warranty can be transferred to a new owner.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, unauthorized modifications, damage due to improper handling or installation.
Environment limits
Not specified
Read the official warranty document (PDF)

Fault & error codes — Growatt MID 20KTL3-XH

From the install manual

14 documented

Showing 14 of 14. The official install manual is the authoritative source — always confirm before acting.

  • Error 200criticalCall your installer
    Manual (PDF)

    DC Arc Fault

    Likely cause
    Wiring issue with the PV panels or connections.
    What to do
    Check the panel wiring after shutdown. If persistent, contact Growatt support.
  • Error 201criticalCall your installer
    Manual (PDF)

    Leakage current is too high

    Likely cause
    Electrical leakage in the system.
    What to do
    Restart the inverter. If error persists, contact Growatt support.
  • Error 203criticalCall your installer
    Manual (PDF)

    PV insulation resistance low

    Likely cause
    Insulation breakdown or improper grounding.
    What to do
    Shutdown and check if the panel frame is grounded reliably. Contact support if error persists.
  • Error 303criticalCall your installer
    Manual (PDF)

    NE abnormal

    Likely cause
    PE cable connection issue.
    What to do
    Check if the PE cable is securely connected. Contact support if error persists.
  • Error 400criticalCall your installer
    Manual (PDF)

    DCI bias abnormal

    Likely cause
    Component failure.
    What to do
    Restart the inverter. Contact support if error persists.
  • Error 404criticalCall your installer
    Manual (PDF)

    Bus sample fault

    Likely cause
    Component failure.
    What to do
    Restart the inverter. Contact support if error persists.
  • Error 500criticalCall your installer
    Manual (PDF)

    BMS Communication fault

    Likely cause
    RS485 cable issue or battery in sleep mode.
    What to do
    Check the cable connection and battery status. Contact support if error persists.
  • Error 202warningCall your installer
    Manual (PDF)

    The DC input voltage exceeds the upper threshold

    Likely cause
    Higher than normal input voltage from PV panels.
    What to do
    Disconnect the DC switch and check the voltage. Contact Growatt if error persists.
  • Error 204warningCall your installer
    Manual (PDF)

    PV terminals reversed

    Likely cause
    Improper connection of PV terminals.
    What to do
    Check the connection of the PV terminals. Restart inverter if error persists.
  • Error 300warningCall your installer
    Manual (PDF)

    AC V Outrange

    Likely cause
    Grid voltage out of specified range.
    What to do
    Check grid voltage. Contact support if error persists.
  • Error 301warningCall your installer
    Manual (PDF)

    AC terminals reversed

    Likely cause
    Improper connection of AC terminals.
    What to do
    Check the connection of the AC terminals. Contact support if error persists.
  • Error 403warningCall your installer
    Manual (PDF)

    Output current unbalanced

    Likely cause
    Unbalanced load in system.
    What to do
    Check if the output current is unbalanced. Contact support if error persists.
  • Error 503warningCall your installer
    Manual (PDF)

    Battery voltage high

    Likely cause
    Battery voltage exceeds permissible range.
    What to do
    Check voltage and replace battery if necessary. Restart inverter if error persists.
  • Error 302info
    Manual (PDF)

    No AC Connection

    Likely cause
    AC wiring issue or power outage.
    What to do
    Check AC wiring. Contact support if error persists.

More Shenzhen Growatt New Energy Co Ltd inverters

MID 17KTL3-XH (AS4777-2 2020)

17 kW · 3φ

MID 15KTL3-XH (AS4777-2 2020)

15 kW · 3φ

MID 25KTL3-XH (AS4777-2 2020)

25 kW · 3φ

MID 13KTL3-XH (AS4777-2 2020)

13 kW · 3φ

MID 12KTL3-XH (AS4777-2 2020)

12 kW · 3φ

MID 11KTL3-XH (AS4777-2 2020)

11 kW · 3φ

View all Shenzhen Growatt New Energy Co Ltd inverters

More from Growatt

Other CEC-approved products from Growatt available in Australia.

Growatt Batteries

ALP 10.0L-E1

10 kWh · LFP

ALP 10.0L-E2

10 kWh · LFP

ALP 15.0L-E1

15 kWh · LFP

ALP 15.0L-E2

15 kWh · LFP

ALP 20.0L-E1

20 kWh · LFP

ALP 20.0L-E2

20 kWh · LFP

View all Growatt batteries
View full Growatt manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?