- Home
- Inverters
- Redback Technologies
- RED-H4-S05HV
Hybrid inverter · Redback Technologies · CEC approved October 2026
Redback Technologies RED-H4-S05HV
CEC listing: RED-H4-S05HV (AS4777-2 2020)
A 5 kW single-phase hybrid inverter that is battery-ready.
- Rated power
- 5kW
- How much solar it can run at once
- Battery-ready
- Yes
- A battery plugs straight in
- Feed-in credits (DEBS)
- Yes
- DEBS pays for exports only when the inverter is 5 kW or less
Key specs, in plain terms
The numbers that matter for a home. The full datasheet is below.
- Rated power
- 5kW
- How much solar it can turn into usable power at once
- Max efficiency
- Not on file: we don't have this figure from the manufacturer's documents yet
- How much of the solar you make reaches the house
- Phases
- Single
- Runs on a standard single-phase supply
- Type
- Hybrid
- Runs solar and a battery from one unit
- Warranty
- 5yr
- How long Redback Energy Pty Ltd stands behind it
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
What we can tell you
Read from the figures on this page. No review written yet.
- It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
- It runs on a standard single-phase supply.
- This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.
- It is CEC-approved, which a new install needs to qualify for STCs.
Features and CEC approval
- Battery compatible
- Yes
- Backup capable
- Yes
- CEC approved
- 8 Oct 2026
- Approval expiry
- 8 Oct 2029
- Status
- Active
- Listed for STCs
- Yes
About Redback Technologies
- Years on the CEC list
- 5 years
- Australian office
- Yes
- Category
- Budget
- CEC-approved inverters
- 34
- CEC-approved batteries
- 14
Documents
WA compliance
- Synergy's list
- Not listed
- Remote management
- No record
This model isn't on Synergy's list dated 6 November 2026, so it has no battery-storage (DER-Storage) listing, which the WA Battery Scheme needs.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. We don't have a remote-management record for this model.
Australian office
Has local presence
Website
redbacktech.comPerth performance
Estimate for a full-size array on this inverter
- Daily yield
- 21.2 kWh
- Annual yield
- 7,755 kWh
At 5 peak sun hours a day (BOM) with a 15% system derate.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Full datasheet
Every figure on file for the Redback Technologies RED-H4-S05HV, by section.
| Specification | Value |
|---|---|
| Installation requirements | |
| Top clearance | 500 mm |
| Side clearance | 300 mm |
| AC breaker | 32 A |
| Cable gauge | 10 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | No |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
How it compares
The Redback Technologies RED-H4-S05HV against the closest-power inverters from other brands.
| Specification | Redback Technologies RED-H4-S05HVRedback Technologies | Cornick Genius IA5Cornick | Hinen A5000SHinen |
|---|---|---|---|
| Rated power? | 4.999 kW | 4.999 kW | 4.999 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Hybrid | Solar | Hybrid |
| Battery ready | Yes | No | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
5-year inverter warranty
Redback Technologies RED-H4-S05HVThis warranty covers the inverter for 5 years, excluding damages from improper use. To claim, contact your installer with the invoice and serial number.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
- Coverage shape
- Full-replacement coverage
- If you sell the home
- Transfers to the next homeowner
- What voids it
- Failure to comply with operation instructions, faulty installation, misuse, damage during transport, insufficient ventilation, unauthorized interference, force majeure.
Fault & error codes — Redback Technologies RED-H4-S05HV
From the install manual
Showing 8 of 8. The official install manual is the authoritative source — always confirm before acting.
- Manual (PDF)
202criticalCall your installerThe DC input voltage is exceeding the maximum tolerable value
- Likely cause
- PV voltage is too high
- What to do
- Disconnect the DC switch immediately and check the voltage of each PV string with a multimeter.
- Manual (PDF)
203criticalCall your installerInsulation problem
- Likely cause
- Poor grounding or damaged insulation
- What to do
- Check if panels are grounded properly, inverter grounding, and impedance of PV lines. If issues persist, contact Growatt.
- Manual (PDF)
407criticalCall your installerAuto test didn't pass
- Likely cause
- Initial tests have failed
- What to do
- Restart the inverter and repeat auto test. If the issue persists, contact Growatt.
- Manual (PDF)
201warningCall your installerLeakage current too high
- Likely cause
- High leakage current detected in the system
- What to do
- Restart the inverter. If the error persists, contact Growatt.
- Manual (PDF)
300warningCall your installerUtility grid voltage is out of permissible range
- Likely cause
- AC grid voltage fluctuation
- What to do
- Switch off the DC switch and check AC wiring and grid voltage.
- Manual (PDF)
302warningCall your installerNo AC connection
- Likely cause
- AC wiring issues
- What to do
- Check AC wiring and the status of AC breaker.
- Manual (PDF)
303warningCall your installerVoltage of Neutral and PE above 30V
- Likely cause
- Improper grounding
- What to do
- Check voltage of Neutral and PE. If issues persist, contact the manufacturer.
- Manual (PDF)
304warningCall your installerUtility grid frequency out of permissible range
- Likely cause
- AC grid frequency fluctuation
- What to do
- Switch off the DC switch and check AC wiring.
More Redback Technologies inverters
RED-H3-S05HV (AS4777-2 2020)
4.999 kW · 1φ
SH5000 (AS4777-2 2020)
5 kW · 1φ
SH5000-G3 (AS4777-2 2020)
5 kW · 1φ
SH5000-G3 (AS4777-2 2020)
5 kW · 1φ
SH5000-G3V2 (AS4777-2 2020)
5 kW · 1φ
SI5000 (AS4777-2 2020)
5 kW · 1φ
More from Redback Technologies
Other CEC-approved products from Redback Technologies available in Australia.
Want to take the next step?
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.