Hybrid inverter · Pylontech · CEC approved July 2026
CEC listing: FHM-8K-HY-1P (AS4777-2 2020)
An 8 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Pylontech FHM-8K-HY-1P, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 97.6% |
| European efficiency | 97% |
| Physical | |
| IP rating | IP65 |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| Top clearance | 500 mm |
| Side clearance | 200 mm |
| AC breaker | 40 A |
| Cable gauge | 6 mm² |
| Earthing method | Null |
| DNSP pre-approval | No |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Website
en.pylontech.com.cnThe Pylontech FHM-8K-HY-1P against the closest-power inverters from other brands.
| Specification | Pylontech FHM-8K-HY-1PPylontech | Energizer Force 8.0HS+Energizer | Energizer Force 8.0HT+Energizer |
|---|---|---|---|
| Rated power? | 8 kW | 8 kW | 8 kW |
| Max efficiency? | 97.6% | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers the heat exchanger for 5 years against defects. Modifications void coverage; claims can be made by contacting support.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.
01criticalCall your installerDC bus voltage exceeds the upper threshold
02criticalCall your installerDC bus voltage falls below the lower threshold
03criticalCall your installerDC bus voltage soft-start is time-out
04criticalCall your installerInverter soft-start is time-out
05criticalCall your installerAn Inverter overcurrent event is detected
06criticalCall your installerOver temperature fault
07criticalCall your installerA relay failure event is detected
08criticalCall your installerDC component in the output current exceeds the upper threshold
09criticalCall your installerPV input voltage exceeds the upper threshold
10criticalCall your installerAuxiliary power failed
11criticalCall your installerOver-current on PV input is detected
12criticalCall your installerLeakage current exceeds the allowable range
13criticalCall your installerPV insulation resistance is too low
14criticalCall your installerInverter DC component exceeds the allowable range
15criticalCall your installerA difference occurred in the readings from the main and secondary controllers
16criticalCall your installerLeakage current CT failed
17criticalCall your installerCommunication with the main and secondary controllers is interrupted
20criticalCall your installerDischarge circuit fault
21criticalCall your installerSoft start in battery discharge fails
22criticalCall your installerCharging voltage is too high
24criticalCall your installerBattery disconnected
25criticalCall your installerInverter current is too high for a long time
26criticalCall your installerShort circuited on inverter output
29criticalCall your installerCharger failure
31criticalCall your installerReverse connection of input and output wires
23warningOverload fault
27warningFan fault
28warningCall your installerOP Current Sensor fault
30warningCall your installerVersion mismatch between controller board and power board
FH3X-8K-HY-1P-10 (AS4777-2 2020)
8 kW · 1φ
FH3X-8K-HY-1P-15 (AS4777-2 2020)
8 kW · 1φ
FH3X-8K-HY-1P-20 (AS4777-2 2020)
8 kW · 1φ
FH3X-6K-HY-1P-10 (AS4777-2 2020)
6 kW · 1φ
FH3X-6K-HY-1P-15 (AS4777-2 2020)
6 kW · 1φ
FH3X-6K-HY-1P-20 (AS4777-2 2020)
6 kW · 1φ
Other CEC-approved products from Pylontech available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.