Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Pylontech
  4. FHM-5K-HY-1P

Hybrid inverter · Pylontech · CEC approved July 2026

Pylontech FHM-5K-HY-1P

CEC listing: FHM-5K-HY-1P (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

FHM-5K-HY-1P: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Pylon Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Pylontech FHM-5K-HY-1P, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.6%
European efficiency97%
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance500 mm
Side clearance200 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodNull
DNSP pre-approvalNo

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
27 July 2026
Approval expiry
27 July 2029
Status
Active
Listed for STCs
Yes

About Pylontech

Years on the CEC list
9 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
36
CEC-approved batteries
79
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

en.pylontech.com.cn
9 years on the CEC list

How it compares

The Pylontech FHM-5K-HY-1P against the closest-power inverters from other brands.

Specification
Pylontech FHM-5K-HY-1PPylontech
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

5-year inverter warranty

Pylontech FHM-5K-HY-1P

This warranty covers the heat exchanger for 5 years against defects. Modifications void coverage; claims can be made by contacting support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voids for non-accredited installation, modification, or tampering.
Environment limits
None stated
Read the official warranty document (PDF)

Fault & error codes — Pylontech FHM-5K-HY-1P

From the install manual

29 documented

Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.

  • 01criticalCall your installer
    Manual (PDF)

    DC bus voltage exceeds the upper threshold

    Likely cause
    Inverter getting too much voltage from the DC input.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 02criticalCall your installer
    Manual (PDF)

    DC bus voltage falls below the lower threshold

    Likely cause
    Insufficient voltage from the DC input.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 03criticalCall your installer
    Manual (PDF)

    DC bus voltage soft-start is time-out

    Likely cause
    Inverter failed to start correctly due to voltage issues.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 04criticalCall your installer
    Manual (PDF)

    Inverter soft-start is time-out

    Likely cause
    Inverter failed to start within the allowed time.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 05criticalCall your installer
    Manual (PDF)

    An Inverter overcurrent event is detected

    Likely cause
    Too much current flowing through the inverter.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 06criticalCall your installer
    Manual (PDF)

    Over temperature fault

    Likely cause
    Internal component overheating.
    What to do
    Allow the inverter to cool down to room temperature, check ventilation.
  • 07criticalCall your installer
    Manual (PDF)

    A relay failure event is detected

    Likely cause
    Relay malfunction inside the inverter.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 08criticalCall your installer
    Manual (PDF)

    DC component in the output current exceeds the upper threshold

    Likely cause
    Excessive DC current detected in inverter output.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 09criticalCall your installer
    Manual (PDF)

    PV input voltage exceeds the upper threshold

    Likely cause
    Voltage from PV panels too high.
    What to do
    Check the open circuit voltage of PV; if it exceeds 500VDC, troubleshoot the system.
  • 10criticalCall your installer
    Manual (PDF)

    Auxiliary power failed

    Likely cause
    Failure in inverter's auxiliary power supply.
    What to do
    Turn off the inverter and restart it.
  • 11criticalCall your installer
    Manual (PDF)

    Over-current on PV input is detected

    Likely cause
    Current flowing from PV is too high.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 12criticalCall your installer
    Manual (PDF)

    Leakage current exceeds the allowable range

    Likely cause
    High ground voltage detected.
    What to do
    Check grounding; ensure proper connections before restarting.
  • 13criticalCall your installer
    Manual (PDF)

    PV insulation resistance is too low

    Likely cause
    Ground insulation issues.
    What to do
    Check insulation resistance; reconnect properly and troubleshoot if necessary.
  • 14criticalCall your installer
    Manual (PDF)

    Inverter DC component exceeds the allowable range

    Likely cause
    DC component too high, risking damage.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 15criticalCall your installer
    Manual (PDF)

    A difference occurred in the readings from the main and secondary controllers

    Likely cause
    Communication error between controllers.
    What to do
    Disconnect AC and DC circuit breakers; restart the inverter.
  • 16criticalCall your installer
    Manual (PDF)

    Leakage current CT failed

    Likely cause
    Leakage current detected indicating a fault.
    What to do
    Disconnect AC circuit breaker first, then disconnect the DC circuit breaker. Wait for the LCD screen to turn off, reconnect DC first, then AC.
  • 17criticalCall your installer
    Manual (PDF)

    Communication with the main and secondary controllers is interrupted

    Likely cause
    Communication line error.
    What to do
    Disconnect AC and DC circuit breakers; restart the inverter.
  • 20criticalCall your installer
    Manual (PDF)

    Discharge circuit fault

    Likely cause
    Fault in the discharge circuit.
    What to do
    Contact your installer for further assistance.
  • 21criticalCall your installer
    Manual (PDF)

    Soft start in battery discharge fails

    Likely cause
    Discharge circuit failure.
    What to do
    Check for faults in battery discharge setup; contact installer if necessary.
  • 22criticalCall your installer
    Manual (PDF)

    Charging voltage is too high

    Likely cause
    Check battery connections; incorrect voltage setting.
    What to do
    Reconnect battery properly and restart the inverter.
  • 24criticalCall your installer
    Manual (PDF)

    Battery disconnected

    Likely cause
    Battery cable not securely connected.
    What to do
    Check battery connections; contact installer if issue persists.
  • 25criticalCall your installer
    Manual (PDF)

    Inverter current is too high for a long time

    Likely cause
    Excessive loads connected to the inverter.
    What to do
    Reduce load to within inverter capacity and restart it.
  • 26criticalCall your installer
    Manual (PDF)

    Short circuited on inverter output

    Likely cause
    Fault in the load circuit.
    What to do
    Turn off the inverter, disconnect circuit breakers and check loads before restarting.
  • 29criticalCall your installer
    Manual (PDF)

    Charger failure

    Likely cause
    Fault in the inverter charging mechanism.
    What to do
    Restart the inverter to check for recovery; contact installer if needed.
  • 31criticalCall your installer
    Manual (PDF)

    Reverse connection of input and output wires

    Likely cause
    Improper wiring connections.
    What to do
    Check all wire connections, especially AC output and grid connections; restart inverter.
  • 23warning
    Manual (PDF)

    Overload fault

    Likely cause
    Total power consumption exceeds inverter capacity.
    What to do
    Reduce load to within inverter capacity and restart it.
  • 27warning
    Manual (PDF)

    Fan fault

    Likely cause
    Cooling fans not operating.
    What to do
    Check if fans are working; restart the inverter if necessary.
  • 28warningCall your installer
    Manual (PDF)

    OP Current Sensor fault

    Likely cause
    Fault in current sensing circuitry.
    What to do
    Restart inverter to see if it resolves the issue; contact installer if persists.
  • 30warningCall your installer
    Manual (PDF)

    Version mismatch between controller board and power board

    Likely cause
    Controller and power board software incompatibility.
    What to do
    Restart inverter; contact installer for assistance if message persists.

More Pylon Technologies Co Ltd inverters

FH3X-5K-HY-1P-10 (AS4777-2 2020)

5 kW · 1φ

FH3X-5K-HY-1P-15 (AS4777-2 2020)

5 kW · 1φ

FH3X-5K-HY-1P-20 (AS4777-2 2020)

5 kW · 1φ

FH3X-5K-HY-1P-5 (AS4777-2 2020)

5 kW · 1φ

FH3X-6K-HY-1P-10 (AS4777-2 2020)

6 kW · 1φ

FH3X-6K-HY-1P-15 (AS4777-2 2020)

6 kW · 1φ

View all Pylon Technologies Co Ltd inverters

More from Pylontech

Other CEC-approved products from Pylontech available in Australia.

Pylontech Batteries

Powercube-H2-48-240V

15.98 kWh

Powercube-H2-48-288V

19.17 kWh

Powercube-H2-48-336V

22.37 kWh

Powercube-H2-48-384V

25.56 kWh

Powercube-H2-48-432V

28.76 kWh

Powercube-H2-48-480V

31.95 kWh

View all Pylontech batteries
View full Pylontech manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?