Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Deye
  4. SUN-6K-G04-AU

Solar inverter · Deye · CEC approved March 2026

Deye SUN-6K-G04-AU

CEC listing: SUN-6K-G04-AU (AS4777-2 2020)

A 6 kW single-phase solar inverter.

Rated power
6kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SUN-6K-G04-AU: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
6kW
How much solar it can turn into usable power at once
Max efficiency
98.3%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
10yr
How long NingBo Deye Inverter Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Deye SUN-6K-G04-AU, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.3%
Physical
IP ratingIP65
Installation requirements
Top clearance500 mm
Side clearance500 mm
AC breaker45 A
Cable gauge10 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time4 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
6 Mar 2026
Approval expiry
6 May 2027
Status
Active
Listed for STCs
Yes

About Deye

Years on the CEC list
6 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
90
CEC-approved batteries
53
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
25.5 kWh
Annual yield
9,308 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

au.deyeinverter.com
6 years on the CEC list

How it compares

The Deye SUN-6K-G04-AU against the closest-power inverters from other brands.

Specification
Deye SUN-6K-G04-AUDeye
Energizer FORCE 6.0HSEnergizer
Energizer Force 6.0HT+Energizer
Rated power?6 kW6 kW6 kW
Max efficiency?98.3%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Deye SUN-6K-G04-AU

This inverter is covered for 10 years, with important exclusions for improper installation. To claim, contact customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Improper installation, modification, or tampering voids the warranty.
Environment limits
.
Read the official warranty document (PDF)

Fault & error codes — Deye SUN-6K-G04-AU

From the install manual

64 documented

Showing 64 of 64. The official install manual is the authoritative source — always confirm before acting.

  • F02criticalCall your installer
    Manual (PDF)

    DC insulation impedance permanent fault

    Likely cause
    Check the grounding cable of inverter.
    What to do
    Ensure proper grounding and insulation is intact.
  • F04criticalCall your installer
    Manual (PDF)

    Ground fault GFDI

    Likely cause
    Check the solar panel output connection.
    What to do
    Inspect connections and ensure proper grounding.
  • F06criticalCall your installer
    Manual (PDF)

    Write the memory error

    Likely cause
    Failure in writing memory (EEPROM). Restart the inverter if the fault still exists, contact your installer or Deye service.
    What to do
    Restart inverter or contact installer.
  • F10criticalCall your installer
    Manual (PDF)

    Auxiliary switch power supply failure

    Likely cause
    DC 12V is not existed. Restart inverter, if the fault still exists, please contact your installer.
    What to do
    Restart the inverter and check the auxiliary supply.
  • F15criticalCall your installer
    Manual (PDF)

    AC firmware over current

    Likely cause
    The internal AC sensor or detection circuit may loose.
    What to do
    Restart the inverter, if the error still exists, please contact your installer or Deye service.
  • F16criticalCall your installer
    Manual (PDF)

    GFCI(RCD) AC leakage current fault

    Likely cause
    This fault means the average leakage current is over 300mA.
    What to do
    Check leakage current sensor or circuit.
  • F18criticalCall your installer
    Manual (PDF)

    AC over current fault of hardware

    Likely cause
    Check AC sensor or detection circuit.
    What to do
    Restart the inverter, if the error still exists, please contact your installer or Deye service.
  • F20criticalCall your installer
    Manual (PDF)

    DC over current fault of the hardware

    Likely cause
    Check whether solar panel output current is within the allowed range.
    What to do
    Check connections and electrical outputs.
  • F22criticalCall your installer
    Manual (PDF)

    Crash stop (if there is a stop button)

    Likely cause
    Contact your installer for help.
    What to do
    Contact installer.
  • F24criticalCall your installer
    Manual (PDF)

    DC insulation impedance failure

    Likely cause
    Check main board or detection on control board.
    What to do
    Inspect and check grounding of the inverter.
  • F30criticalCall your installer
    Manual (PDF)

    AC main contactor failure

    Likely cause
    Check relays and AC voltage of relays.
    What to do
    Inspect and replace relays if necessary.
  • F35criticalCall your installer
    Manual (PDF)

    No AC grid

    Likely cause
    Check AC grid voltage.
    What to do
    Inspect and confirm AC grid status.
  • F39criticalCall your installer
    Manual (PDF)

    AC over current(one cycle)

    Likely cause
    Check AC current sensor and its circuit.
    What to do
    Inspect AC current sensor and connections.
  • F41criticalCall your installer
    Manual (PDF)

    AC Line W,U over voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Inspect AC voltage settings and connections.
  • F42criticalCall your installer
    Manual (PDF)

    AC Line W,U low voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Inspect and adjust the AC voltage settings.
  • F43criticalCall your installer
    Manual (PDF)

    AC Line V,W over voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Inspect AC voltage provisions.
  • F44criticalCall your installer
    Manual (PDF)

    AC Line V,W low voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Consult electrical provisions for adjustments.
  • F45criticalCall your installer
    Manual (PDF)

    AC Line U,V over voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Investigate and resolve AC over voltage.
  • F46criticalCall your installer
    Manual (PDF)

    AC Line U,V low voltage

    Likely cause
    Check the AC voltage protection setting.
    What to do
    Review AC voltage settings and verify supply.
  • F47criticalCall your installer
    Manual (PDF)

    AC Over frequency

    Likely cause
    Check the frequency protection setting.
    What to do
    Inspect settings and actual frequencies.
  • F48criticalCall your installer
    Manual (PDF)

    AC lower frequency

    Likely cause
    Check the frequency protection setting.
    What to do
    Adjust frequency settings as needed.
  • F55criticalCall your installer
    Manual (PDF)

    DC busbar voltage is too high

    Likely cause
    Check PV voltage and Ubus voltage and its detection circuit.
    What to do
    Inspect and adjust solar panel connections accordingly.
  • F56criticalCall your installer
    Manual (PDF)

    DC busbar voltage is too low

    Likely cause
    It tells the PV input voltage is low and tends to happen in early morning.
    What to do
    Ensure that the PV power supply is sufficient in morning hours.
  • F63criticalCall your installer
    Manual (PDF)

    ARC fault

    Likely cause
    Check PV module cable connection and clear the fault.
    What to do
    Investigate cables and connections, rectify faults.
  • F64criticalCall your installer
    Manual (PDF)

    IGBT heat sink high temperature

    Likely cause
    Check temperature sensor and firmware compatibility.
    What to do
    Inspect cooling and thermal management.
  • F01warning
    Manual (PDF)

    DC input polarity reverse fault

    Likely cause
    Check the PV input polarity.
    What to do
    Check and correct the DC input polarity.
  • F03warning
    Manual (PDF)

    DC leakage current fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for return of this error.
  • F05warningCall your installer
    Manual (PDF)

    Read the memory error

    Likely cause
    Failure in reading memory (EEPROM). Restart the inverter if the fault still exists, contact your installer or Deye service.
    What to do
    Restart the inverter and check the error status.
  • F13warning
    Manual (PDF)

    Working mode changed/Grid mode changed

    Likely cause
    Lost of one phase or AC voltage detection circuit or relays not closed.
    What to do
    Check AC voltage and phase.
  • F23warning
    Manual (PDF)

    AC leakage current is transient over current

    Likely cause
    Check whether DC power supply or solar panels is ok.
    What to do
    Monitor the leakage current sensor.
  • F26warning
    Manual (PDF)

    The DC busbar is unbalanced

    Likely cause
    Check whether the BUSN cable or driver board power supply cable is loose.
    What to do
    Inspect DC connections and tighten any loose cables.
  • F31warning
    Manual (PDF)

    DC boost soft start

    Likely cause
    Check relays and its driver signal.
    What to do
    Monitor for this error during start-up.
  • F57warning
    Manual (PDF)

    AC reverse irrigation

    Likely cause
    AC reverse irrigation.
    What to do
    Monitor performance based on conditions.
  • F07info
    Manual (PDF)

    GFDI blown fuse

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F08info
    Manual (PDF)

    GFDI grounding touch failure

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F09info
    Manual (PDF)

    IGBT damaged by excessive drop voltage

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F11info
    Manual (PDF)

    AC main contactor errors

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F12info
    Manual (PDF)

    AC auxiliary contactor errors

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F14info
    Manual (PDF)

    DC firmware over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F17info
    Manual (PDF)

    Three phase current, over-current fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F19info
    Manual (PDF)

    All hardware failure synthesis

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F21info
    Manual (PDF)

    DC leakage flow fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F25info
    Manual (PDF)

    DC feedback fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F27info
    Manual (PDF)

    DC end insulation error

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F28info
    Manual (PDF)

    Inverter 1 DC high fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F29info
    Manual (PDF)

    AC load switch failure

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F32info
    Manual (PDF)

    Inverter 2 dc high fault

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F33info
    Manual (PDF)

    AC over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F34info
    Manual (PDF)

    AC current over load

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F36info
    Manual (PDF)

    AC grid phase error

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F37info
    Manual (PDF)

    AC three-phase voltage unbalance failure

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F38info
    Manual (PDF)

    AC three-phase current unbalance failure

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F40info
    Manual (PDF)

    DC over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F49info
    Manual (PDF)

    U phase grid current DC component over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F50info
    Manual (PDF)

    V phase grid current DC component over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F51info
    Manual (PDF)

    W phase grid current DC component over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F52info
    Manual (PDF)

    AC inductor A,phase current DC current high

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F53info
    Manual (PDF)

    AC inductor B,phase current DC current high

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F54info
    Manual (PDF)

    AC inductor C,phase current DC current high

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F58info
    Manual (PDF)

    AC grid U over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F59info
    Manual (PDF)

    AC grid V over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F60info
    Manual (PDF)

    AC grid W over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F61info
    Manual (PDF)

    Reactor A phase over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.
  • F62info
    Manual (PDF)

    Reactor B phase over current

    Likely cause
    Hardly appear the code. Never ever happened so far.
    What to do
    Monitor for reoccurrence.

More NingBo Deye Inverter Technology Co Ltd inverters

AI-W5.1-6P1-AU-B (AS4777-2 2020)

6 kW · 1φ

SUN-6K-SG02LP1-AU-AM2 (AS4777-2 2020)

6 kW · 1φ

SUN-6K-SG04LP1-AU (AS4777-2 2020)

6 kW · 1φ

AI-W5.1-5P1-AU-B (AS4777-2 2020)

5 kW · 1φ

SUN-5K-G04-AU (AS4777-2 2020)

5 kW · 1φ

SUN-5K-SG02LP1-AU-AM2 (AS4777-2 2020)

5 kW · 1φ

View all NingBo Deye Inverter Technology Co Ltd inverters

More from Deye

Other CEC-approved products from Deye available in Australia.

Deye Batteries

AI-W10.2-B

10.24 kWh · LFP

AI-W15.3-B

15.36 kWh · LFP

AI-W20.4-B

20.48 kWh · LFP

AI-W25.6-B

25.6 kWh · LFP

AI-W30.7-B

30.72 kWh · LFP

AI-W5.1-B

5.12 kWh · LFP

View all Deye batteries
View full Deye manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters