Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Morningstar
  4. GS-MPPT-80M-200V

Solar inverter · Morningstar · CEC approved June 2024

Morningstar GS-MPPT-80M-200V

A single-phase solar inverter.

Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
Not on file: we don't have this figure from the manufacturer's documents yet
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
5yr
How long Morningstar Corporation stands behind it

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Morningstar GS-MPPT-80M-200V, by section.

Full datasheet, by section
SpecificationValue
Physical
Operating temperature-30°C to 45°C
Installation requirements
Top clearance150 mm
Side clearance75 mm
AC breaker80 A
Cable gauge53.5 mm²
Earthing methodNegative Ground
DNSP pre-approvalNo
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
5 June 2024
Approval expiry
5 June 2027
Status
Active
Listed for STCs
Yes

About Morningstar

Years on the CEC list
2 years
Australian office
Not verified
Category
Unknown
CEC-approved inverters
3
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

2 years on the CEC list

Documents

  • DatasheetOpens in a new tab
  • Warranty terms and installation guide and user manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

5-year inverter warranty

Morningstar GS-MPPT-80M-200V

This warranty covers defects in materials and workmanship for five years. Exclusions include damage from improper use and exceeding ratings. For claims, contact an authorized dealer for assistance.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Damage by accident, negligence, abuse or improper use; PV or load currents exceeding the ratings of the product; Unauthorized product modification or attempted repair; Damage occurring during shipment; Damage resulting from acts of nature.
Environment limits
/
Read the official warranty document (PDF)

Fault & error codes — Morningstar GS-MPPT-80M-200V

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • Charging Status High Heatsink TemperaturecriticalCall your installer
    Manual (PDF)

    Heatsink temperature is too high.

    Likely cause
    Excessive current or poor ventilation.
    What to do
    Reduce load or improve ventilation.
  • Firmware Update FailurecriticalCall your installer
    Manual (PDF)

    Firmware update was not successful.

    Likely cause
    Failed firmware update process.
    What to do
    Retry firmware update.
  • Heatsink Temperature Sensor Open / ShortedcriticalCall your installer
    Manual (PDF)

    The heatsink temperature sensor is damaged.

    Likely cause
    Faulty heatsink temperature sensor.
    What to do
    Contact your Authorized Morningstar Dealer for service.
  • High Battery Voltage Disconnect (HVD)criticalCall your installer
    Manual (PDF)

    Battery voltage is above normal operating limits.

    Likely cause
    Other charging sources charging the battery above regulation voltage.
    What to do
    Disconnect other charging sources, check settings.
  • High Input Voltage Current LimitcriticalCall your installer
    Manual (PDF)

    The solar input voltage is too high.

    Likely cause
    Solar array Voc approaching maximum input voltage rating.
    What to do
    Ensure array Voc does not exceed 200V.
  • High Temperature Current LimitcriticalCall your installer
    Manual (PDF)

    Heatsink temperature exceeds safe limits.

    Likely cause
    Insufficient airflow or excessively high ambient temperature.
    What to do
    Provide better airflow or move controller to cooler location.
  • Battery Sense Out of Range / Disconnectedwarning
    Manual (PDF)

    Battery sense wire is disconnected. Inspect the battery sense connections.

    Likely cause
    A battery sense wire is disconnected.
    What to do
    Inspect battery sense connections.
  • Current Limitwarning
    Manual (PDF)

    The array power exceeds the rating of the controller.

    Likely cause
    GenStar MPPT is limiting battery current to the maximum current rating.
    What to do
    Check array power and reduce if necessary.
  • Load Short Circuitwarning
    Manual (PDF)

    Detected a short circuit in load wiring.

    Likely cause
    Faulty wiring or component causing short circuit.
    What to do
    Inspect load wiring for shorts.
  • RTS Openwarning
    Manual (PDF)

    Remote Temperature Sensor not connected.

    Likely cause
    RTS connection is faulty or disconnected.
    What to do
    Reconnect RTS sensor for proper operation.
  • UncalibratedwarningCall your installer
    Manual (PDF)

    The controller was not factory calibrated.

    Likely cause
    Lack of calibration.
    What to do
    Contact your Authorized Morningstar Dealer for service.

More Morningstar Corporation inverters

GS-MPPT-100M-200V

0 kW · 1φ

GS-MPPT-60M-200V

0 kW · 1φ

View all Morningstar Corporation inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?