Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Jiangsu Weiheng Intelligent Technology
  4. WH-THA802

Hybrid inverter · Jiangsu Weiheng Intelligent Technology · CEC approved July 2024

Jiangsu Weiheng Intelligent Technology WH-THA802

CEC listing: WH-THA802 (AS4777-2 2020)

An 8 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

WH-THA802: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Jiangsu Weiheng Intelligent Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Jiangsu Weiheng Intelligent Technology WH-THA802, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98%
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance200 mm
AC breaker32 A
Cable gauge6 mm²
Earthing methodClass I
DNSP pre-approvalNo
Estimated install time4 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
11 July 2024
Approval expiry
11 July 2027
Status
Active
Listed for STCs
Yes

About Jiangsu Weiheng Intelligent Technology

Years on the CEC list
2 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
32
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

2 years on the CEC list

How it compares

The Jiangsu Weiheng Intelligent Technology WH-THA802 against the closest-power inverters from other brands.

Specification
Jiangsu Weiheng Intelligent Technology WH-THA802Jiangsu Weiheng Intelligent Technology
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty termsPDF, opens in a new tab
  • Installation guide and user manual and compliance certificatePDF, opens in a new tab

10-year inverter warranty

Jiangsu Weiheng Intelligent Technology WH-THA802

This warranty covers the inverter for 10 years and allows transfer once. It excludes issues from non-accredited installations and modifications. To claim, contact customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modification, tampering.
Environment limits
Temperatures above 60°C, salt spray.
Read the official warranty document (PDF)

Fault & error codes — Jiangsu Weiheng Intelligent Technology WH-THA802

From the install manual

18 documented

Showing 18 of 18. The official install manual is the authoritative source — always confirm before acting.

  • DSP_1warning
    Manual (PDF)

    PV1 overvoltage

    Likely cause
    Check if the open circuit voltage is within the normal voltage range.
    What to do
    Inspect PV1 voltage and ensure it is below the maximum allowable.
  • DSP_10warning
    Manual (PDF)

    No grid power

    Likely cause
    Check grid voltage.
    What to do
    Inspect grid connection and power status.
  • DSP_11warning
    Manual (PDF)

    Grid voltage fault

    Likely cause
    Verify grid voltage levels.
    What to do
    Check grid connection.
  • DSP_12warning
    Manual (PDF)

    Grid current fault

    Likely cause
    Check EPS load power for compliance.
    What to do
    Confirm EPS load is within normal limits.
  • DSP_13warning
    Manual (PDF)

    Grid frequency fault

    Likely cause
    Check grid frequency levels.
    What to do
    Ensure grid frequency is normal.
  • DSP_14warning
    Manual (PDF)

    Overheat fault

    Likely cause
    Cooling system malfunction.
    What to do
    Ensure the cooling system functions properly.
  • DSP_16warningCall your installer
    Manual (PDF)

    Current over-leak fault

    Likely cause
    Inspect solar panel and device wiring.
    What to do
    Check for wiring issues and leakage.
  • DSP_17warningCall your installer
    Manual (PDF)

    Isolation resistance fault

    Likely cause
    Inspect solar panels and wiring system.
    What to do
    Check isolation resistance and ensure safety.
  • DSP_2warning
    Manual (PDF)

    PV1 overcurrent

    Likely cause
    Verify that PV1 is correctly connected.
    What to do
    Check connections and load on PV1.
  • DSP_26warningCall your installer
    Manual (PDF)

    Battery voltage fault

    Likely cause
    Verify that battery voltages are within limits.
    What to do
    Check battery voltage ranges.
  • DSP_3warning
    Manual (PDF)

    PV2 overvoltage

    Likely cause
    Ensure PV2 is within the rated voltage range.
    What to do
    Check and adjust PV2 voltage.
  • DSP_37warningCall your installer
    Manual (PDF)

    EPS voltage fault

    Likely cause
    EPS load power may exceed limits.
    What to do
    Check EPS load capacity.
  • DSP_38warning
    Manual (PDF)

    EPS current fault

    Likely cause
    EPS load power may exceed limits.
    What to do
    Ensure EPS load is within specified range.
  • DSP_39warning
    Manual (PDF)

    EPS overload fault

    Likely cause
    EPS load exceeds safe limits.
    What to do
    Reduce load to meet EPS requirements.
  • DSP_4warning
    Manual (PDF)

    PV2 overcurrent

    Likely cause
    Confirm that PV1 is correctly connected.
    What to do
    Inspect load on PV2 and make necessary adjustments.
  • DSP_40warningCall your installer
    Manual (PDF)

    EPS short circuit fault

    Likely cause
    Check loading conditions on EPS.
    What to do
    Inspect for short circuit conditions.
  • DSP_41warningCall your installer
    Manual (PDF)

    Earth & Neutral wire fault

    Likely cause
    Check wiring of earth and neutral wires.
    What to do
    Ensure proper wiring standards are followed.
  • DSP_9warning
    Manual (PDF)

    PV voltage abnormal

    Likely cause
    Ensure PV readings are normal.
    What to do
    Check system voltage.

More Jiangsu Weiheng Intelligent Technology Co Ltd inverters

WH-TIA802 (AS4777-2 2020)

8 kW · 3φ

WH-THA602 (AS4777-2 2020)

6 kW · 3φ

WH-TIA602 (AS4777-2 2020)

6 kW · 3φ

WH-THA103 (AS4777-2 2020)

10 kW · 3φ

WH-TIA103 (AS4777-2 2020)

10 kW · 3φ

WH-THA502 (AS4777-2 2020)

5 kW · 3φ

View all Jiangsu Weiheng Intelligent Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?