Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Jiangsu Weiheng Intelligent Technology
  4. WH-SPHA3.6H-5.12kWh

Solar inverter · Jiangsu Weiheng Intelligent Technology · Not listed as CEC approved

Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWh

CEC listing: WH-SPHA3.6H-5.12kWh (AS4777-2 2020)

A 3.6 kW single-phase solar inverter that is listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
3.6kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

WH-SPHA3.6H-5.12kWh: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • The register doesn't currently list it as CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.6kW
How much solar it can turn into usable power at once
Max efficiency
97.6%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
10yr
How long Jiangsu Weiheng Intelligent Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWh, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power3.6 kW
Maximum power3.6 kW
Apparent power3.6 kVA
Phases1
Efficiency
Max efficiency97.6%
European efficiency97%
CEC-weighted efficiency99.9%
DC input & MPPT
MPPT trackers2
Max input voltage600 V
MPPT voltage min100 V
MPPT voltage max550 V
Max input current12.5 A
Battery & backup
Battery compatibleYes
Backup capableYes
Continuous backup3.6 kW
Physical
Dimensions (H×W×D)1125 × 550 × 233 mm
Weight68 kg
IP ratingIP65
CoolingNatural
Operating temperature-10°C to 55°C
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance800 mm
Side clearance500 mm
AC breaker50 A
Cable gauge10 mm²
Earthing methodNot specified
DNSP pre-approvalNo
Estimated install time10 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
Yes
CEC approved
7 Aug 2024
Approval expiry
11 Jan 2027
Status
Not listed
Listed for STCs
No (not listed)

About Jiangsu Weiheng Intelligent Technology

Years on the CEC list
2 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
32
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
15.3 kWh
Annual yield
5,585 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

2 years on the CEC list

How it compares

The Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWh against the closest-power inverters from other brands.

Specification
Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWhJiangsu Weiheng Intelligent Technology
Energizer Force 3.6SEnergizer
Afore AF3.6K-SL-1Afore
Rated power?3.6 kW3.6 kW3.6 kW
Max efficiency?97.6%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarSolarHybrid
Battery readyNoNoYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty terms and installation guidePDF, opens in a new tab

10-year inverter warranty

Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWh

This warranty covers defects for 10 years. Capacity must be at least 70% after 10 years. Warranty voided by unauthorized modifications.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Void if improperly installed or modified by unauthorized individuals.
Environment limits
Salt spray, flooding, temperatures above 55°C.
Read the official warranty document (PDF)

Fault & error codes — Jiangsu Weiheng Intelligent Technology WH-SPHA3.6H-5.12kWh

From the install manual

3 documented

Showing 3 of 3. The official install manual is the authoritative source — always confirm before acting.

  • BATTERY_COM_FAULTcriticalCall your installer
    Manual (PDF)

    Battery communication fault

    Likely cause
    Loose connections or faulty battery modules
    What to do
    Check connections and ensure all battery modules are functioning properly. If the fault remains, contact an installer.
  • DSP_FAULTwarningCall your installer
    Manual (PDF)

    Digital Signal Processor fault

    Likely cause
    Possible software issue or component failure
    What to do
    Restart the system and check if the fault persists.
  • METER_COM_FAULTwarningCall your installer
    Manual (PDF)

    Meter communication fault

    Likely cause
    Issues with meter connections or meter failure
    What to do
    Check the meter connections. If the issue persists, consult your installer.

More Jiangsu Weiheng Intelligent Technology Co Ltd inverters

WH-SPHA3.6H-10.24kWh (AS4777-2 2020)

3.6 kW · 1φ

WH-SPHA3.6H-10.24kWh (AS4777-2 2020)

3.6 kW · 1φ

WH-SPHA3.6H-5.12kWh (AS4777-2 2020)

3.6 kW · 1φ

SIA-3.6kW (AS4777-2 2020)

3.68 kW · 1φ

SIA-4.6kW (AS4777-2 2020)

4.6 kW · 1φ

SIA-5kW (AS4777-2 2020)

4.999 kW · 1φ

View all Jiangsu Weiheng Intelligent Technology Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?