Hybrid inverter · Koyoe · Not listed as CEC approved
CEC listing: KY-1Hybrid-5k0-H (AS4777-2 2020)
A 5 kW single-phase hybrid inverter that is battery-ready.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Koyoe KY-1Hybrid-5k0-H, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 5 kW |
| Maximum power | 5.5 kW |
| Apparent power | 5 kVA |
| Phases | 1 |
| Efficiency | |
| Max efficiency | 99% |
| European efficiency | 98% |
| CEC-weighted efficiency | 95% |
| DC input & MPPT | |
| MPPT trackers | 2 |
| Max input voltage | 550 V |
| MPPT voltage min | 120 V |
| MPPT voltage max | 500 V |
| Max input current | 18 A |
| Battery & backup | |
| Battery compatible | Yes |
| Backup capable | Yes |
| Continuous backup | 5 kW |
| Physical | |
| Dimensions (H×W×D) | 390 × 500 × 185 mm |
| Weight | 18 kg |
| IP rating | IP65 |
| Cooling | Natural Convection |
| Operating temperature | -25°C to 60°C |
| Installation requirements | |
| Top clearance | 100 mm |
| Side clearance | 100 mm |
| AC breaker | 40 A |
| Cable gauge | 6 mm² |
| Earthing method | TT |
| DNSP pre-approval | Yes |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Koyoe KY-1Hybrid-5k0-H against the closest-power inverters from other brands.
| Specification | Energizer FORCE 5.0HSEnergizer | Energizer Force 5.0HT+Energizer | |
|---|---|---|---|
| Rated power? | 5 kW | 5 kW | 5 kW |
| Max efficiency? | 99.0% | Not on file | Not on file |
| MPPT trackers? | 2 | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers defects for 60 months. It excludes damages from improper installation. To claim, provide the original invoice and warranty card.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 26 of 26. The official install manual is the authoritative source — always confirm before acting.
1criticalCall your installerGFCI Fault
4criticalCall your installerPV Overvoltage Fault
5criticalCall your installerIsolation Fault
8criticalCall your installerBus Voltage High
9criticalCall your installerOff Grid Over Voltage Fault
Battery Over Temperature FaultcriticalCall your installerBattery temperature exceeds safe levels.
Battery Voltage Low FaultcriticalCall your installerBattery voltage is too low.
Bus Voltage HighcriticalCall your installerInverter bus voltage exceeds safe levels.
GFCI FaultcriticalCall your installerGrounding fault current leakage protector activated.
Isolation FaultcriticalCall your installerIneffective grounding of inverter detected.
Off Grid Over Voltage FaultcriticalCall your installerHigh off-grid output voltage detected.
PV Overvoltage FaultcriticalCall your installerPhotovoltaic input voltage exceeds safe limits.
10warningCall your installerBattery Over Temperature Fault
11warningCall your installerInverter Module Over Temperature Fault
12warningCall your installerBattery Voltage Low Fault
13warningLow Ambient Temperature Warn
2warningCall your installerBMS Communication Fault
3warningCall your installerSPI Communication Fault
6warningGrid Voltage Fault
7warningGrid Frequency Fault
BMS Communication FaultwarningBattery Management System communication failure.
Grid Frequency FaultwarningGrid frequency out of allowed range detected.
Grid Voltage FaultwarningGrid voltage out of allowed range detected.
Inverter Module Over Temperature FaultwarningInverter module overheating detected.
Low ambient Temperature WarnwarningAmbient temperature is below allowable levels.
SPI Communication FaultwarningCall your installerMaster-slave DSP communication failure.
KY-1Hybrid-5k0-H (AS4777-2 2020)
5 kW · 1φ
KY-EST06KH (AS4777-2 2020)
6 kW · 1φ
KY-EST08KH (AS4777-2 2020)
8 kW · 1φ
KY-3GT-10k0 (AS4777-2 2020)
10 kW · 1φ
KY-EST10KH (AS4777-2 2020)
10 kW · 1φ
KY-3GT-12k0 (AS4777-2 2020)
12 kW · 1φ
Other CEC-approved products from Koyoe available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.