Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Koyoe
  4. KY-1Hybrid-5k0-H

Hybrid inverter · Koyoe · CEC approved June 2025

Koyoe KY-1Hybrid-5k0-H

CEC listing: KY-1Hybrid-5k0-H (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready.

Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

KY-1Hybrid-5k0-H: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
5yr
How long Jiangsu Koyoe Energy Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Koyoe KY-1Hybrid-5k0-H, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Physical
IP ratingIP65
Operating temperature-25°C to 60°C
Installation requirements
Top clearance100 mm
Side clearance100 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodTT
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
27 June 2025
Approval expiry
24 Apr 2027
Status
Active
Listed for STCs
Yes

About Koyoe

Years on the CEC list
4 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
21
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

4 years on the CEC list

How it compares

The Koyoe KY-1Hybrid-5k0-H against the closest-power inverters from other brands.

Specification
Koyoe KY-1Hybrid-5k0-HKoyoe
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty5 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and compliance certificateOpens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab

5-year inverter warranty

Koyoe KY-1Hybrid-5k0-H

This warranty covers defects for 60 months. It excludes damages from improper installation. To claim, provide the original invoice and warranty card.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
non-accredited installation, modification, tampering, transportation damage, improper use
Environment limits
none specified
Read the official warranty document (PDF)

Fault & error codes — Koyoe KY-1Hybrid-5k0-H

From the install manual

26 documented

Showing 26 of 26. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    GFCI Fault

    Likely cause
    The grounding current is too high. Disconnecting the AC side circuit and detecting the peripheral equipment of the AC system.
    What to do
    Check the grounding and reconnect after addressing the fault.
  • 4criticalCall your installer
    Manual (PDF)

    PV Overvoltage Fault

    Likely cause
    PV input voltage exceeds 550V.
    What to do
    Check PV input voltage to be below 550V.
  • 5criticalCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    Inverter not effectively earthed, or impedance check needed.
    What to do
    Check grounding connections and impedance between poles.
  • 8criticalCall your installer
    Manual (PDF)

    Bus Voltage High

    Likely cause
    PV input voltage exceeds 550V.
    What to do
    Check PV input voltage to be below 550V.
  • 9criticalCall your installer
    Manual (PDF)

    Off Grid Over Voltage Fault

    Likely cause
    High off-grid output voltage.
    What to do
    Check proper connections and load functioning correctly.
  • Battery Over Temperature FaultcriticalCall your installer
    Manual (PDF)

    Battery temperature exceeds safe levels.

    Likely cause
    Battery placed in a high-temperature environment.
    What to do
    Move battery to a cooler area and restart the inverter after cooling.
  • Battery Voltage Low FaultcriticalCall your installer
    Manual (PDF)

    Battery voltage is too low.

    Likely cause
    Poor connection or failure of the battery.
    What to do
    Check battery connections and verify battery functionality; restart inverter.
  • Bus Voltage HighcriticalCall your installer
    Manual (PDF)

    Inverter bus voltage exceeds safe levels.

    Likely cause
    PV input voltage is above 550V.
    What to do
    Check PV voltage levels; reduce if necessary, and restart inverter.
  • GFCI FaultcriticalCall your installer
    Manual (PDF)

    Grounding fault current leakage protector activated.

    Likely cause
    The grounding current is too high, possibly due to a fault in the AC system or connections.
    What to do
    Disconnect AC side circuit, check for issues with photovoltaic cells and peripheral AC equipment.
  • Isolation FaultcriticalCall your installer
    Manual (PDF)

    Ineffective grounding of inverter detected.

    Likely cause
    Poor earthing or high impedance between PV poles.
    What to do
    Check grounding and ensure PV inputs are correctly earthed.
  • Off Grid Over Voltage FaultcriticalCall your installer
    Manual (PDF)

    High off-grid output voltage detected.

    Likely cause
    Faulty connection or abnormal load on the off-grid output.
    What to do
    Ensure off-grid connections are correct; troubleshoot load issues.
  • PV Overvoltage FaultcriticalCall your installer
    Manual (PDF)

    Photovoltaic input voltage exceeds safe limits.

    Likely cause
    PV input voltage is higher than 550V.
    What to do
    Check the PV input voltage; reduce it if necessary.
  • 10warningCall your installer
    Manual (PDF)

    Battery Over Temperature Fault

    Likely cause
    Battery temperature is too high.
    What to do
    Allow battery to cool before restarting.
  • 11warningCall your installer
    Manual (PDF)

    Inverter Module Over Temperature Fault

    Likely cause
    High temperature of inverter module or blocked heat sink.
    What to do
    Ensure work environment is normal and allow cooldown.
  • 12warningCall your installer
    Manual (PDF)

    Battery Voltage Low Fault

    Likely cause
    Low voltage battery malfunction or incorrect connection.
    What to do
    Check battery connections and functionality, restart inverter if needed.
  • 13warning
    Manual (PDF)

    Low Ambient Temperature Warn

    Likely cause
    Ambient temperature too low for operation.
    What to do
    Ensure ambient temperature is normal before restarting.
  • 2warningCall your installer
    Manual (PDF)

    BMS Communication Fault

    Likely cause
    Communication between the battery pack and the inverter failed. Check communication cable connection.
    What to do
    Restart the inverter after replacing the connecting cable.
  • 3warningCall your installer
    Manual (PDF)

    SPI Communication Fault

    Likely cause
    Master-slave DSP communication failure.
    What to do
    Restart the inverter. If fails, contact customer service.
  • 6warning
    Manual (PDF)

    Grid Voltage Fault

    Likely cause
    Network voltage too low or high.
    What to do
    Check and restart the inverter once grid is normal.
  • 7warning
    Manual (PDF)

    Grid Frequency Fault

    Likely cause
    Grid frequency too low or high.
    What to do
    Check and restart the inverter once grid is normal.
  • BMS Communication Faultwarning
    Manual (PDF)

    Battery Management System communication failure.

    Likely cause
    Poor connection of communication cable between battery pack and inverter.
    What to do
    Ensure cables are connected securely and reliably, then restart the inverter.
  • Grid Frequency Faultwarning
    Manual (PDF)

    Grid frequency out of allowed range detected.

    Likely cause
    Frequency from the grid is not within specifications.
    What to do
    Check grid frequency; restart inverter if normal.
  • Grid Voltage Faultwarning
    Manual (PDF)

    Grid voltage out of allowed range detected.

    Likely cause
    Voltage from the grid is too low or too high.
    What to do
    Check grid voltage; restart inverter when power returns to normal.
  • Inverter Module Over Temperature Faultwarning
    Manual (PDF)

    Inverter module overheating detected.

    Likely cause
    Blocked heat sink or high ambient temperature.
    What to do
    Check ventilation; allow inverter to cool before operation.
  • Low ambient Temperature Warnwarning
    Manual (PDF)

    Ambient temperature is below allowable levels.

    Likely cause
    Environmental conditions affecting inverter and battery operation.
    What to do
    Check ambient temperature; restart inverter once conditions improve.
  • SPI Communication FaultwarningCall your installer
    Manual (PDF)

    Master-slave DSP communication failure.

    Likely cause
    Failure in communication, possibly due to a restart requirement.
    What to do
    Restart the inverter; contact customer service if the issue persists.

More Jiangsu Koyoe Energy Technology Co Ltd inverters

KY-1Hybrid-5k0-H (AS4777-2 2020)

5 kW · 1φ

KY-EST06KH (AS4777-2 2020)

6 kW · 1φ

KY-EST08KH (AS4777-2 2020)

8 kW · 1φ

KY-3GT-10k0 (AS4777-2 2020)

10 kW · 1φ

KY-EST10KH (AS4777-2 2020)

10 kW · 1φ

KY-3GT-12k0 (AS4777-2 2020)

12 kW · 1φ

View all Jiangsu Koyoe Energy Technology Co Ltd inverters

More from Koyoe

Other CEC-approved products from Koyoe available in Australia.

Koyoe Batteries

KY-102V40AH

3.2786 kWh · LFP

KY-204V40AH

6.5536 kWh · LFP

KY-306V40AH

9.8304 kWh · LFP

KY-408V40AH

13.1072 kWh · LFP

KY-510V40AH

16.384 kWh · LFP

KY-51V105AH-S

4.8384 kWh · LFP

View all Koyoe batteries
View full Koyoe manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?