Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. iStore
  4. IS-INV-40000-3PH

Solar inverter · iStore · CEC approved May 2024

iStore IS-INV-40000-3PH

CEC listing: IS-INV-40000-3PH (AS4777-2 2020)

A 40 kW three-phase solar inverter.

Rated power
40kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter

Commercial-scale inverter

At 40 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

IS-INV-40000-3PH: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
40kW
How much solar it can turn into usable power at once
Max efficiency
98.7%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Solar
Runs solar only
Warranty
2yr
How long iStore (QLD) Pty Ltd stands behind it

Full datasheet

Every figure on file for the iStore IS-INV-40000-3PH, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.7%
European efficiency98.4%
Physical
Dimensions (H×W×D)530 × 640 × 270 mm
Weight43 kg
IP ratingIP66
Installation requirements
Cable gauge6 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
24 May 2024
Approval expiry
24 May 2027
Status
Active
Listed for STCs
Yes

About iStore

Years on the CEC list
3 years
Australian office
Yes
Category
Budget
CEC-approved inverters
12
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Australian office

Has local presence

Website

www.istore.net.au
3 years on the CEC list

How it compares

The iStore IS-INV-40000-3PH against the closest-power inverters from other brands.

Specification
iStore IS-INV-40000-3PHiStore
Solplanet ASW40K-LT-G3Solplanet
Solis S5-GC40K-AUSolis
Rated power?40 kW40 kW40 kW
Max efficiency?98.7%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeSolarSolarSolar
Battery readyNoNoNo
Warranty2 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

2-year inverter warranty

iStore IS-INV-40000-3PH

This warranty covers parts for 2 years, with a free extension available. Exclusions include voiding due to improper installation or modifications, and claims can be made by contacting customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modifications, improper input voltage beyond specifications
Environment limits
Operating temperature range: -25 ~ +60 °C (Derating above 45 °C @ Rated output power)
Read the official warranty document (PDF)

Fault & error codes — iStore IS-INV-40000-3PH

From the install manual

9 documented

Showing 9 of 9. The official install manual is the authoritative source — always confirm before acting.

  • 2001criticalCall your installer
    Manual (PDF)

    High string input voltage

    Likely cause
    The PV array is not properly configured. Excessive PV modules are connected in series to the PV string, and therefore the PV string open-circuit voltage exceeds the maximum inverter operating voltage.
    What to do
    Reduce the number of PV modules connected in series to the PV string until the PV string open-circuit voltage is less than or equal to the maximum inverter operating voltage.
  • 2002criticalCall your installer
    Manual (PDF)

    DC arc fault

    Likely cause
    The PV string power cables arc or are in poor contact.
    What to do
    Check whether the PV string cables arc or are in poor contact.
  • 2009criticalCall your installer
    Manual (PDF)

    String Short-Circuited to Ground

    Likely cause
    The PV array is short-circuited to ground. The ambient environment of PV arrays is moist.
    What to do
    Check the output-to-ground impedance of the PV array. If a short circuit or inadequate insulation is detected, rectify it.
  • 2011criticalCall your installer
    Manual (PDF)

    String reverse connection

    Likely cause
    The PV string polarity is reversed.
    What to do
    Check whether the PV string is connected to the device in reverse polarity. If yes, wait until the PV string current decreases to below 0.5 A, set DC SWITCH to OFF, and adjust the PV string polarity.
  • 2013critical
    Manual (PDF)

    Grid loss

    Likely cause
    Power grid outage occurs. The AC circuit is disconnected or the AC switch is off.
    What to do
    Check whether the AC circuit is disconnected or the AC switch is off.
  • 2021criticalCall your installer
    Manual (PDF)

    AFCI self-check failure

    Likely cause
    The AFCI self-check fails.
    What to do
    Turn off the AC output switch and DC input switch, and then turn them on after 5 minutes. If the alarm persists, contact ISTORE technical support.
  • 2031criticalCall your installer
    Manual (PDF)

    Phase wire short-circuited to PE

    Likely cause
    The impedance of the output phase wire to PE is low or the output phase wire is short-circuited to PE.
    What to do
    Check the impedance of the output phase wire to PE, locate the position with low impedance, and rectify the fault.
  • 2062criticalCall your installer
    Manual (PDF)

    Low insulation resistance

    Likely cause
    The PV array is short-circuited with PE. The PV string has been in a moist environment for a long time and the circuit is not well insulated to ground.
    What to do
    Check the impedance between the PV string and the PE cable. If a short circuit occurs, rectify the fault.
  • 2012warning
    Manual (PDF)

    String current backfeed

    Likely cause
    The number of PV modules connected in series to the PV string is insufficient. As a result, the terminal voltage is lower than that of other strings.
    What to do
    Check whether the number of PV modules connected in series to the PV string is less than that of other PV strings. If yes, wait until the PV string current drops below 0.5 A, turn off all DC switches, and adjust the number of PV modules in the PV string.

More iStore (QLD) Pty Ltd inverters

IS-INV-29900-3PH (AS4777-2 2020)

29.9 kW · 3φ

IS-HYB-25000-3PH (AS4777-2 2020)

25 kW · 3φ

IS-HYB-15000-3PH (AS4777-2 2020)

15 kW · 3φ

IS-HYB-10000-3PH (AS4777-2 2020)

9.999 kW · 3φ

IS-HYB-6000-3PH (AS4777-2 2020)

6 kW · 3φ

IS-HYB-5000-3PH (AS4777-2 2020)

5 kW · 3φ

View all iStore (QLD) Pty Ltd inverters

More from iStore

Other CEC-approved products from iStore available in Australia.

iStore Batteries

IS-BATT-10000-S0

10 kWh · LFP

IS-BATT-14000-S1

13.8 kWh · LFP

IS-BATT-15000-S0

15 kWh · LFP

IS-BATT-21000-S1

20.7 kWh · LFP

IS-BATT-5000-S0

5 kWh · LFP

IS-BATT-7000-S1

6.9 kWh · LFP

View all iStore batteries
View full iStore manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?