Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SAJ
  4. R5 series
  5. R5-4K-T2-15

Solar inverter · SAJ · R5 series · CEC approval expired

SAJ R5-4K-T2-15

CEC listing: R5-4K-T2-15 (AS4777-2 2020)

A 4 kW single-phase solar inverter.

Rated power
4kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

R5-4K-T2-15: the short answer

In the R5 seriesThe 8th of 13 sizes, from 0.7 to 10 kW
4kWThe 8th of 13 sizes, from 0.7 to 10 kW
Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

Other sizes in the R5 series

  • 0.7 kW
  • 1 kW
  • 1.5 kW
  • 2 kW
  • 2.5 kW
  • 3 kW
  • 3.7 kW
  • 4 kW (this one)
  • 5 kW
  • 6 kW
  • 7 kW
  • 8 kW
  • 10 kW

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
4kW
How much solar it can turn into usable power at once
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only

Full datasheet

Every figure on file for the SAJ R5-4K-T2-15, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.2%
DC input & MPPT
MPPT trackers1
Physical
IP ratingIP65
Installation requirements
Cable gauge16 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
2 Feb 2022
Approval expiry
2 May 2025
Status
Not listed
Listed for STCs
No (not listed)

About SAJ

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
104
CEC-approved batteries
34
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
17.0 kWh
Annual yield
6,205 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.saj-electric.com
8 years on the CEC list

How it compares

The SAJ R5-4K-T2-15 against the closest-power inverters from other brands.

Specification
SAJ R5-4K-T2-15SAJ
Afore AF4K-SLAfore
Afore HNS4000TLAfore
Rated power?4 kW4 kW4 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
WarrantyNot on fileNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab

Warranty summary

SAJ provides a 5-year standard warranty for inverters that covers defects in design or manufacture. The warranty is voided by unauthorized modifications or installations.

5-year inverter warranty

SAJ R5-4K-T2-15

SAJ provides a 5-year standard warranty for inverters that covers defects in design or manufacture. The warranty is voided by unauthorized modifications or installations.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voided by unauthorized product modifications, improper installations, or failure to follow safety guidelines.
Environment limits
/ -40° C to +60° C
Read the official warranty document (PDF)

Fault & error codes — SAJ R5-4K-T2-15

From the install manual

40 documented

Showing 40 of 40. The official install manual is the authoritative source — always confirm before acting.

  • 03criticalCall your installer
    Manual (PDF)

    High Temperature Master

    Likely cause
    Inverter overheating
    What to do
    Check whether the radiator is blocked or if the inverter is in too high or too low temperature. If normal, contact support.
  • 24criticalCall your installer
    Manual (PDF)

    Grid Lost Error Master

    Likely cause
    Lost connection to grid
    What to do
    Check the connection status between the inverter and the grid, troubleshoot.
  • 31criticalCall your installer
    Manual (PDF)

    Insulation Error Master

    Likely cause
    Insulation resistance failure
    What to do
    Check insulation resistance, contact support if normal.
  • 33criticalCall your installer
    Manual (PDF)

    Over Bus Voltage Master

    Likely cause
    Bus voltage exceeds limits
    What to do
    Check settings of the solar panel; if normal, contact support.
  • 38criticalCall your installer
    Manual (PDF)

    Bus Hardware Overvoltage Master

    Likely cause
    Overvoltage in hardware components
    What to do
    Contact SAJ technical support immediately for inspection.
  • 39criticalCall your installer
    Manual (PDF)

    PV1 Hardware Overcurrent Master

    Likely cause
    Overcurrent detected in PV1 circuit
    What to do
    Check PV1 connections; contact support if normal.
  • 40criticalCall your installer
    Manual (PDF)

    PV2 Hardware Overcurrent Master

    Likely cause
    Overcurrent detected in PV2 circuit
    What to do
    Check PV2 connections; contact support if normal.
  • 41criticalCall your installer
    Manual (PDF)

    Hardware Overcurrent Master

    Likely cause
    General hardware overcurrent detected
    What to do
    Contact SAJ technical support for assistance.
  • 44criticalCall your installer
    Manual (PDF)

    Null line voltage to earth fault Master

    Likely cause
    Fault in line voltage to earth
    What to do
    Contact support immediately for inspection.
  • 73criticalCall your installer
    Manual (PDF)

    Grid Lost Error Slave

    Likely cause
    Lost communication or connection with the grid
    What to do
    Check AC connection and grid status; contact support if normal.
  • 01warningCall your installer
    Manual (PDF)

    Relay Error Master

    Likely cause
    Faulty relay or connection issue
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 02warningCall your installer
    Manual (PDF)

    Storer Error Master

    Likely cause
    Fault in energy storage system
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 04warningCall your installer
    Manual (PDF)

    Low Temperature Master

    Likely cause
    Inverter too cold for operation
    What to do
    Ensure inverter is within operational temperature range. If the condition remains unsolved, contact support.
  • 05warningCall your installer
    Manual (PDF)

    Interior Communication Error Master

    Likely cause
    Communication issue within the inverter
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 06warningCall your installer
    Manual (PDF)

    GFCI Devices Error Master

    Likely cause
    Fault in GFCI device
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 07warningCall your installer
    Manual (PDF)

    DCI Devices Error Master

    Likely cause
    Fault in DCI device
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 08warningCall your installer
    Manual (PDF)

    Current Sensor Error Master

    Likely cause
    Faulty current sensor
    What to do
    If this error occurs frequently, please contact your distributor or call SAJ technical support.
  • 09warningCall your installer
    Manual (PDF)

    Grid Over Voltage Master

    Likely cause
    Voltage exceeds grid limits
    What to do
    Check the volt of the grid; if too high, inquire local grid workers about adjustment.
  • 10warningCall your installer
    Manual (PDF)

    Grid Low Voltage Master

    Likely cause
    Voltage below grid limits
    What to do
    Check the connection between the inverter and the grid, and settings of on-grid standards.
  • 15warningCall your installer
    Manual (PDF)

    High average voltage of 10 minutes Master

    Likely cause
    Sustained high voltage
    What to do
    Check grid voltage levels and contact support if the issue persists.
  • 18warningCall your installer
    Manual (PDF)

    Over Frequency Master

    Likely cause
    Frequency exceeds operational limits
    What to do
    Check the setting of country and frequency. Contact support if normal.
  • 19warningCall your installer
    Manual (PDF)

    Low Frequency Master

    Likely cause
    Frequency below operational limits
    What to do
    Check the setting of country and frequency. Contact support if normal.
  • 27warningCall your installer
    Manual (PDF)

    GFCI Error Master

    Likely cause
    Ground fault detected
    What to do
    Check insulation resistance of solar panel; contact support if normal.
  • 28warningCall your installer
    Manual (PDF)

    DCI Error Master

    Likely cause
    Fault detected in DCI system
    What to do
    If this error always exists, please contact your distributor or call SAJ technical support.
  • 34warningCall your installer
    Manual (PDF)

    Under Bus Voltage Master

    Likely cause
    Bus voltage below limits
    What to do
    Contact SAJ support for further assistance.
  • 35warningCall your installer
    Manual (PDF)

    Overcurrent Master

    Likely cause
    Current exceeds limits
    What to do
    Check connections and stability of grid voltage. Contact support if normal.
  • 45warningCall your installer
    Manual (PDF)

    Fan Error Master

    Likely cause
    Fault in fan operation
    What to do
    Check for blockages or issues with the fan. Contact support if normal.
  • 49warningCall your installer
    Manual (PDF)

    Loss of communication between Power Meter and Control Board Master

    Likely cause
    Communication interruption
    What to do
    Check connections; contact support if normal.
  • 50warningCall your installer
    Manual (PDF)

    Interior Communication Error Slave

    Likely cause
    Communication failure in slave components
    What to do
    Contact SAJ technical support for assistance.
  • 51warningCall your installer
    Manual (PDF)

    Voltage Consistency Error Slave

    Likely cause
    Inconsistent voltage readings
    What to do
    Contact SAJ for troubleshooting support.
  • 54warningCall your installer
    Manual (PDF)

    Frequency Consistency Error Slave

    Likely cause
    Inconsistent frequency readings
    What to do
    Contact SAJ for troubleshooting support.
  • 57warningCall your installer
    Manual (PDF)

    GFCI Consistency Error Slave

    Likely cause
    Inconsistent GFCI readings
    What to do
    Contact SAJ for troubleshooting support.
  • 61warningCall your installer
    Manual (PDF)

    Overvoltage Slave

    Likely cause
    Voltage exceeds safe levels for slave components
    What to do
    Contact SAJ for troubleshooting support.
  • 62warningCall your installer
    Manual (PDF)

    Under Voltage Slave

    Likely cause
    Voltage below safe levels for slave components
    What to do
    Contact SAJ for troubleshooting support.
  • 67warningCall your installer
    Manual (PDF)

    Over Frequency Slave

    Likely cause
    Frequency exceeds safe levels for slave components
    What to do
    Contact SAJ for troubleshooting support.
  • 68warningCall your installer
    Manual (PDF)

    Under Frequency Slave

    Likely cause
    Frequency below safe levels for slave components
    What to do
    Contact SAJ for troubleshooting support.
  • 76warningCall your installer
    Manual (PDF)

    PV1 Overvoltage Slave

    Likely cause
    Overvoltage condition detected in PV1
    What to do
    Check PV1 voltage levels; contact support if normal.
  • 77warningCall your installer
    Manual (PDF)

    PV2 Overvoltage Slave

    Likely cause
    Overvoltage condition detected in PV2
    What to do
    Check PV2 voltage levels; contact support if normal.
  • 81warningCall your installer
    Manual (PDF)

    Loss of Communication between Display Panel and Control Board Master

    Likely cause
    Communication failure between display and control board
    What to do
    Contact SAJ technical support for assistance.
  • 86warningCall your installer
    Manual (PDF)

    DRM0 Error Master

    Likely cause
    Error in DRM system
    What to do
    Contact SAJ technical support for assistance.

More SAJ inverters

H2-4K-S2 (AS4777-2 2020)

4 kW · 1φ

R5-4K-S2-15 (AS4777-2 2020)

4 kW · 1φ

H2-3.6K-S2 (AS4777-2 2020)

3.68 kW · 1φ

R5-3.6K-S2-15 (AS4777-2 2020)

3.68 kW · 1φ

EK70 HS5-5K-S3 (AS4777-2 2020)

4.999 kW · 1φ

EK90 HS5-5K-S3 (AS4777-2 2020)

4.999 kW · 1φ

View all SAJ inverters

More from SAJ

Other CEC-approved products from SAJ available in Australia.

SAJ Batteries

B2-10.0-HV1

9.6 kWh · Lithium-ion

B2-10.0-HV5

9.6 kWh · Lithium-ion

B2-12.8-HV1-S

12.8 kWh · LFP

B2-15.0-HV1

14.4 kWh · Lithium-ion

B2-15.0-HV5

14.4 kWh · Lithium-ion

B2-19.2-HV1-S

19.2 kWh · LFP

View all SAJ batteries
View full SAJ manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?