Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SAJ
  4. EK90 HS5-8K-S3

Hybrid inverter · SAJ · CEC approved September 2026

SAJ EK90 HS5-8K-S3

CEC listing: EK90 HS5-8K-S3 (AS4777-2 2020)

An 8 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

EK90 HS5-8K-S3: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
98.0%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
1
One string of panels, tuned as a whole
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Guangzhou Sanjing Electric Co Ltd stands behind it

Full datasheet

Every figure on file for the SAJ EK90 HS5-8K-S3, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98%
DC input & MPPT
MPPT trackers1
Physical
IP ratingIP66
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance0 mm
Side clearance0 mm
AC breaker63 A
DNSP pre-approvalYes

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
11 Sept 2026
Approval expiry
12 Feb 2028
Status
Active
Listed for STCs
Yes

About SAJ

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
104
CEC-approved batteries
34
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.saj-electric.com
8 years on the CEC list

How it compares

The SAJ EK90 HS5-8K-S3 against the closest-power inverters from other brands.

Specification
SAJ EK90 HS5-8K-S3SAJ
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?98.0%Not on fileNot on file
MPPT trackers?1Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

SAJ EK90 HS5-8K-S3

The warranty covers defects for 10 years, with a 90% capacity retention at year 10. Warranty voids include non-accredited installation. Claims can be made via the support website.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voided for non-accredited installation, modifications, or tampering with the product.
Environment limits
Excessive heat or direct exposure to temperatures above 50°C may void warranty.
Read the official warranty document (PDF)

Fault & error codes — SAJ EK90 HS5-8K-S3

From the install manual

19 documented

Showing 19 of 19. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    Master Relay Error

    Likely cause
    The relay is malfunctioning or not responding.
    What to do
    Restart the unit and check the relay connections.
  • 17criticalCall your installer
    Manual (PDF)

    Master Output_Shorter

    Likely cause
    Short circuit detected at output.
    What to do
    Disconnect immediately and check for shorts.
  • 2criticalCall your installer
    Manual (PDF)

    Master EEPROM Error

    Likely cause
    Corruption in the EEPROM data.
    What to do
    Perform a factory reset or contact support.
  • 3criticalCall your installer
    Manual (PDF)

    Master Temperature High Error

    Likely cause
    Overheating due to insufficient cooling or excessive load.
    What to do
    Check ventilation and reduce load; allow to cool down.
  • 10warningCall your installer
    Manual (PDF)

    Master Phase1 Voltage Low

    Likely cause
    Voltage below acceptable limits on phase 1.
    What to do
    Check the phase supply levels.
  • 11warningCall your installer
    Manual (PDF)

    Master Phase2 Voltage High

    Likely cause
    Voltage exceeding normal range on phase 2.
    What to do
    Check the phase supply levels.
  • 12warningCall your installer
    Manual (PDF)

    Master Phase2 Voltage Low

    Likely cause
    Voltage below acceptable limits on phase 2.
    What to do
    Check the phase supply levels.
  • 13warningCall your installer
    Manual (PDF)

    Master Phase3 Voltage High

    Likely cause
    Voltage exceeding normal range on phase 3.
    What to do
    Check the phase supply levels.
  • 14warningCall your installer
    Manual (PDF)

    Master Phase3 Voltage Low

    Likely cause
    Voltage below acceptable limits on phase 3.
    What to do
    Check the phase supply levels.
  • 15warningCall your installer
    Manual (PDF)

    Master Voltage 10Min High

    Likely cause
    Voltage remained high for an extended period.
    What to do
    Monitor voltage levels and reduce load as necessary.
  • 16warningCall your installer
    Manual (PDF)

    Master OffGrid Voltage Low

    Likely cause
    Voltage too low when off-grid.
    What to do
    Check the battery state and connections.
  • 18warningCall your installer
    Manual (PDF)

    Master Grid Frequency High

    Likely cause
    Grid frequency above normal range.
    What to do
    Check grid conditions and reduce load if necessary.
  • 19warningCall your installer
    Manual (PDF)

    Master Grid Frequency Low

    Likely cause
    Grid frequency below normal range.
    What to do
    Check grid conditions and see if the inverter needs to be reset.
  • 4warning
    Manual (PDF)

    Master Temperature Low Error

    Likely cause
    Ambient temperature below operating limits.
    What to do
    Ensure the system is in a suitable environment.
  • 5warningCall your installer
    Manual (PDF)

    Master Lost Communication M<->S

    Likely cause
    Communication disruption between master and slave units.
    What to do
    Check communication cables and connections.
  • 6warningCall your installer
    Manual (PDF)

    Master GFCI Device Error

    Likely cause
    Trip in Ground Fault Circuit Interrupter.
    What to do
    Inspect the GFCI device and reset it if necessary.
  • 7warningCall your installer
    Manual (PDF)

    Master DCI Device Error

    Likely cause
    Current sensor malfunction.
    What to do
    Check connections to current sensors.
  • 8warningCall your installer
    Manual (PDF)

    Master Current Sensor Error

    Likely cause
    Fault in the current sensing mechanism.
    What to do
    Inspect current sensor connections.
  • 9warningCall your installer
    Manual (PDF)

    Master Phase1 Voltage High

    Likely cause
    Voltage exceeding normal range on phase 1.
    What to do
    Check the phase supply levels.

More Guangzhou Sanjing Electric Co Ltd inverters

EK70 HS5-8K-S3 (AS4777-2 2020)

8 kW · 1φ

H2-8K-S3 (AS4777-2 2020)

8 kW · 1φ

R5-8K-S2-15 (AS4777-2 2020)

8 kW · 1φ

R5-8K-S2 (AS4777-2 2020)

8 kW · 1φ

R5-8K-T2-15 (AS4777-2 2020)

8 kW · 1φ

R5-8K-T2 (AS4777-2 2020)

8 kW · 1φ

View all Guangzhou Sanjing Electric Co Ltd inverters

More from SAJ

Other CEC-approved products from SAJ available in Australia.

SAJ Batteries

B2-10.0-HV1

9.6 kWh · Lithium-ion

B2-10.0-HV5

9.6 kWh · Lithium-ion

B2-12.8-HV1-S

12.8 kWh · LFP

B2-15.0-HV1

14.4 kWh · Lithium-ion

B2-15.0-HV5

14.4 kWh · Lithium-ion

B2-19.2-HV1-S

19.2 kWh · LFP

View all SAJ batteries
View full SAJ manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?