Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SAJ
  4. EK70 HS5-10K-T3

Hybrid inverter · SAJ · CEC approved September 2026

SAJ EK70 HS5-10K-T3

CEC listing: EK70 HS5-10K-T3 (AS4777-2 2020)

A 10 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
10kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

EK70 HS5-10K-T3: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
10kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Guangzhou Sanjing Electric Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the SAJ EK70 HS5-10K-T3, by section.

Full datasheet, by section
SpecificationValue
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance25 mm
Side clearance25 mm
AC breaker16 A
Cable gauge50 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
11 Sept 2026
Approval expiry
12 Feb 2028
Status
Active
Listed for STCs
Yes

About SAJ

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
104
CEC-approved batteries
34
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
42.5 kWh
Annual yield
15,511 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.saj-electric.com
8 years on the CEC list

How it compares

The SAJ EK70 HS5-10K-T3 against the closest-power inverters from other brands.

Specification
SAJ EK70 HS5-10K-T3SAJ
Solplanet ASW010K-SHSolplanet
Solplanet ASW10000-S-ASolplanet
Rated power?9.999 kW9.999 kW9.999 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

10-year inverter warranty

SAJ EK70 HS5-10K-T3

This warranty covers defects for 10 years. Major exclusions include improper installation and environmental damage such as exposure to extreme temperatures. For claims, contact SAJ support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Void if not installed by an accredited professional, modified, or tampered with.
Environment limits
Temperatures above 50°C and exposure to salt spray.
Read the official warranty document (PDF)

Fault & error codes — SAJ EK70 HS5-10K-T3

From the install manual

11 documented

Showing 11 of 11. The official install manual is the authoritative source — always confirm before acting.

  • 1Dx7DcriticalCall your installer
    Manual (PDF)

    High battery voltage

    Likely cause
    Verify that the battery is connected to the inverter as required.
    What to do
    Check the battery connection and ensure it's functioning within normal limits.
  • 1Dx7EcriticalCall your installer
    Manual (PDF)

    Low battery voltage

    Likely cause
    Verify that the battery is connected to the inverter as required.
    What to do
    Check the battery connection and ensure it's functioning within normal limits.
  • 1Dx89criticalCall your installer
    Manual (PDF)

    Internal DC power connection error

    Likely cause
    Verify that the connection between the DCDC PCB and the inverter PCB is connected as required.
    What to do
    Check and confirm the connections between PCBs are secure and correct.
  • 1Dx8AcriticalCall your installer
    Manual (PDF)

    High DC voltage fault

    Likely cause
    Verify that the connection between the DCDC PCB and the inverter PCB is correct and check for short in string-inverter power connection.
    What to do
    Inspect and verify the DC connections for issues.
  • 1Dx8DcriticalCall your installer
    Manual (PDF)

    High battery voltage

    Likely cause
    Verify that the battery is connected to the inverter as required.
    What to do
    Check the battery connection and ensure it's functioning within normal limits.
  • 1Dx8EcriticalCall your installer
    Manual (PDF)

    Low battery voltage

    Likely cause
    Verify that the battery is connected to the inverter as required.
    What to do
    Check the battery connection and ensure it's functioning within normal limits.
  • 1DxA0criticalCall your installer
    Manual (PDF)

    Battery error

    Likely cause
    Call battery vendor support.
    What to do
    Contact battery vendor support for assistance.
  • 1DxA2criticalCall your installer
    Manual (PDF)

    Operation conditions verification failed

    Likely cause
    Verify that the battery is connected to the inverter as required, battery voltage is within range and the battery is enabled (power and communication).
    What to do
    Check connections, voltage, and enable the battery if necessary.
  • 1Dx88warning
    Manual (PDF)

    Internal communication error

    Likely cause
    Verify that the RS485 connector on the communication board is connected as required.
    What to do
    Recheck the RS485 connections and secure as needed.
  • 1Dx9Fwarning
    Manual (PDF)

    Battery communication error

    Likely cause
    Verify that the CAN connectors are connected as required.
    What to do
    Check CAN connections for proper setup.
  • 1DxA1warning
    Manual (PDF)

    Battery not selected

    Likely cause
    Configure battery as required.
    What to do
    Ensure the battery is configured correctly in the system settings.

More Guangzhou Sanjing Electric Co Ltd inverters

EK90 HS5-10K-T3 (AS4777-2 2020)

9.999 kW · 3φ

H2-10K-T3-AU (AS4777-2 2020)

9.999 kW · 3φ

R6-10K-T2-32-AUS (AS4777-2 2020)

9.999 kW · 3φ

R6-10K-T2-AUS (AS4777-2 2020)

9.999 kW · 3φ

H2-10K-T2 (AS4777-2 2020)

10 kW · 3φ

H2-8K-T2 (AS4777-2 2020)

8 kW · 3φ

View all Guangzhou Sanjing Electric Co Ltd inverters

More from SAJ

Other CEC-approved products from SAJ available in Australia.

SAJ Batteries

B2-10.0-HV1

9.6 kWh · Lithium-ion

B2-10.0-HV5

9.6 kWh · Lithium-ion

B2-12.8-HV1-S

12.8 kWh · LFP

B2-15.0-HV1

14.4 kWh · Lithium-ion

B2-15.0-HV5

14.4 kWh · Lithium-ion

B2-19.2-HV1-S

19.2 kWh · LFP

View all SAJ batteries
View full SAJ manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?