Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. GoodWe
  4. GW99.99K-ET-G10

Hybrid inverter · GoodWe · CEC approved June 2026

GoodWe GW99.99K-ET-G10

CEC listing: GW99.99K-ET-G10 (AS4777-2 2020)

A 100 kW three-phase hybrid inverter that is battery-ready.

Rated power
100kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Commercial-scale inverter

At 100 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

GW99.99K-ET-G10: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
100kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
MPPT trackers
8
8 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
25yr
How long GoodWe Technologies Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the GoodWe GW99.99K-ET-G10, by section.

Full datasheet, by section
SpecificationValue
DC input & MPPT
MPPT trackers8
Physical
IP ratingIP66
Installation requirements
Top clearance200 mm
Side clearance150 mm
AC breaker25 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
10 June 2026
Approval expiry
10 June 2029
Status
Active
Listed for STCs
Yes

About GoodWe

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
229
CEC-approved batteries
30
CEC-approved panels
168
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • GoodWe Technologies Co Ltd batteries and panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Australian office

Has local presence

Website

www.goodwe.com.au
12 years on the CEC list

How it compares

The GoodWe GW99.99K-ET-G10 against the closest-power inverters from other brands.

Specification
GoodWe GW99.99K-ET-G10GoodWe
GoodWe GEP100-10GoodWe
GoodWe GW100K-GTGoodWe
Rated power?99.99 kW99.99 kW99.99 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?8Not on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridSolarSolar
Battery readyYesNoNo
Warranty25 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and compliance certificatePDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab

25-year inverter warranty

GoodWe GW99.99K-ET-G10

GoodWe offers a limited warranty of 5 to 25 years against manufacturing defects. Key exclusions include installation errors. Claims can be made via local distributor or through https://goodwetechnology.zendesk.com/hc/en-gb.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, tampering, operation against instructions, normal wear and tear.
Environment limits
Defects caused by exposure to harsh environmental conditions without prior written confirmation (e.g., saltwater, flooding).
Read the official warranty document (PDF)

Fault & error codes — GoodWe GW99.99K-ET-G10

From the install manual

14 documented

Showing 14 of 14. The official install manual is the authoritative source — always confirm before acting.

  • Back-Up Over LoadcriticalCall your installer
    Manual (PDF)

    Back-up side is overloaded

    Likely cause
    Total load power exceeds back-up nominal output power
    What to do
    Reduce the backup load to within the nominal output power limit.
  • Ground FailurecriticalCall your installer
    Manual (PDF)

    Ground leakage current is too high

    Likely cause
    Improper connection of neutral cable on the AC side or high humidity levels
    What to do
    Use a multi-meter to check for voltage between earth and inverter frame; resolve as needed.
  • Isolation FailurecriticalCall your installer
    Manual (PDF)

    Ground insulation impedance of PV string is too low

    Likely cause
    PV panels may not be grounded properly or other issues such as broken DC cables.
    What to do
    Check grounding connections and ensure humidity levels are appropriate; restart inverter if needed.
  • PV/BAT OvervoltagecriticalCall your installer
    Manual (PDF)

    The PV or BAT voltage is too high

    Likely cause
    Total voltage of each PV string is higher than the maximum DC input voltage, or battery voltage is higher than the maximum BAT input voltage
    What to do
    Reduce PV string count and check battery voltage to ensure it is within range.
  • Relay Check FailurecriticalCall your installer
    Manual (PDF)

    Self checking of relay failure

    Likely cause
    Neutral and ground cables are not connected properly on the AC side
    What to do
    Check connections using a multi-meter; if high voltage is detected, reconnect properly.
  • Utility LosscriticalCall your installer
    Manual (PDF)

    Public grid power is not available

    Likely cause
    Inverter does not detect the connection of grid
    What to do
    Check if AC side has voltage. Ensure AC cables are connected tightly. Turn off the AC breaker for 5 minutes and turn it on again.
  • Utility Phase FailurecriticalCall your installer
    Manual (PDF)

    The sequence of the on-grid wire is incorrect

    Likely cause
    The inverter has detected that the phase angles of L2 and L3 are reversed
    What to do
    Check and reconnect the L2 and L3 cables in correct order
  • VAC FailurecriticalCall your installer
    Manual (PDF)

    Grid voltage is not within permissible range

    Likely cause
    Inverter detects that AC voltage is beyond the normal range required by the safety country
    What to do
    Check safety country setting and test AC voltage with a multi-meter. Verify AC cable connections are secure and correct.
  • DC Bus HighwarningCall your installer
    Manual (PDF)

    BUS voltage is over-high

    Likely cause
    May be an occasional situation
    What to do
    Restart the inverter and contact support if the error continues.
  • DC Injection HighwarningCall your installer
    Manual (PDF)

    Higher DC component detected in AC output

    Likely cause
    Occasional situation that may require a restart of the inverter
    What to do
    Restart the inverter and monitor if the problem persists.
  • Over TemperaturewarningCall your installer
    Manual (PDF)

    Temperature inside of the inverter is too high

    Likely cause
    High temperature condition due to surrounding environment
    What to do
    Reduce surroundings temperature and ensure installation guidelines are adhered to.
  • EEPROM R/W Failureinfo
    Manual (PDF)

    Error caused by strong external magnetic field

    Likely cause
    External interference affecting internal memory writes
    What to do
    Restart the inverter and check if the error remains.
  • FAC Failureinfo
    Manual (PDF)

    Grid frequency is not within permissible range

    Likely cause
    Inverter detects that the grid frequency is beyond the normal range required by the safety country
    What to do
    Monitor the inverter display to check AC frequency. If it resolves by itself, no action is needed.
  • SPI Failureinfo
    Manual (PDF)

    Internal communication failure

    Likely cause
    External magnetic field interference
    What to do
    Restart the inverter to see if the issue resolves.

More GoodWe Technologies Co Ltd inverters

GW100K-GT (AS4777-2 2020)

99.99 kW · 3φ

GW100K-HT (AS4777-2 2020)

99.99 kW · 3φ

GW100K-ET-G10 (AS4777-2 2020)

100 kW · 3φ

GW100K-PCS-N-G10 (AS4777-2 2020)

100 kW · 3φ

GW100K-PCS-N-G11 (AS4777-2 2020)

100 kW · 3φ

GW110K-GT (AS4777-2 2020)

110 kW · 3φ

View all GoodWe Technologies Co Ltd inverters

More from GoodWe

Other CEC-approved products from GoodWe available in Australia.

GoodWe Batteries

GW100KWH-D-10

100.8 kWh · LFP

GW102.4-BAT-AC-G10

100 kWh · LFP

GW112.6-BAT-AC-G10

110 kWh · LFP

GW5.1-BAT-D-G20

5 kWh · LFP

GW5.1-BAT-D-G21

5 kWh · LFP

GW6.0-BAT-D-G20

5.9 kWh · LFP

View all GoodWe batteries

GoodWe Solar Panels

BMM-T3/108A(505W)

505W

BMM-T3/108A(510W)

510W

BMM-T3/108A(515W)

515W

BMM-T3/120A(565W)

565W

BMM-T3/120A(570W)

570W

BMM-T3/120A(575W)

575W

View all GoodWe panels
View full GoodWe manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?