Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. GoodWe
  4. GW5000-DNS-30

Solar inverter · GoodWe · CEC approved September 2025

GoodWe GW5000-DNS-30

CEC listing: GW5000-DNS-30 (AS4777-2 2020)

A 5 kW single-phase solar inverter.

Rated power
5kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

GW5000-DNS-30: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
97.9%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
20yr
How long GoodWe Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the GoodWe GW5000-DNS-30, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency97.9%
European efficiency97%
DC input & MPPT
MPPT trackers2
Physical
IP ratingIP66

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
1 Sept 2025
Approval expiry
27 July 2027
Status
Active
Listed for STCs
Yes

About GoodWe

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
229
CEC-approved batteries
30
CEC-approved panels
168
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • GoodWe Technologies Co Ltd batteries and panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.goodwe.com.au
12 years on the CEC list

How it compares

The GoodWe GW5000-DNS-30 against the closest-power inverters from other brands.

Specification
GoodWe GW5000-DNS-30GoodWe
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?97.9%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeSolarHybridHybrid
Battery readyNoYesYes
Warranty20 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

20-year inverter warranty

GoodWe GW5000-DNS-30

This warranty covers hardware costs, including spare parts or unit replacement, at Goodwe’s discretion. Exclusions include non-accredited installations and modifications, and to make a claim, contact your regional sales representative.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Warranty voided for non-accredited installation or modification.
Environment limits
None stated.
Read the official warranty document (PDF)

Fault & error codes — GoodWe GW5000-DNS-30

From the install manual

5 documented

Showing 5 of 5. The official install manual is the authoritative source — always confirm before acting.

  • Grid Frequency InstabilitywarningCall your installer
    Manual (PDF)

    Utility grid exception. The actual grid frequency change rate does not meet the requirement of the local grid standard.

    Likely cause
    If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal.
    What to do
    If the problem occurs frequently, contact the dealer or the after-sales service.
  • Grid OvervoltagewarningCall your installer
    Manual (PDF)

    The grid voltage exceeds the permissible range or the duration of high voltage exceeds the requirement of HVRT.

    Likely cause
    If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal.
    What to do
    If the problem occurs frequently, check whether the grid voltage is within the permissible range or contact the local power company.
  • Grid Rapid OvervoltagewarningCall your installer
    Manual (PDF)

    The grid voltage is abnormal or ultra-high.

    Likely cause
    If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal.
    What to do
    If the problem occurs frequently, check whether the grid voltage is within the allowed range or contact the local power company.
  • Grid UndervoltagewarningCall your installer
    Manual (PDF)

    The grid voltage is lower than the permissible range, or the duration of low voltage exceeds the requirement of LVRT.

    Likely cause
    If the problem occurs occasionally, the utility grid may be abnormal temporarily. The inverter will recover automatically after detecting that the utility grid is normal.
    What to do
    If the problem occurs frequently, check whether the grid voltage is within the permissible range.
  • Utility Losswarning
    Manual (PDF)

    Utility grid power fails or AC cable is disconnected, or the AC breaker is off.

    Likely cause
    The alarm is automatically cleared after the grid power supply is restored or check whether the AC cable is connected and the AC breaker is on.
    What to do
    Check AC connection and ensure the AC breaker is on.

More GoodWe Technologies Co Ltd inverters

GEH5.0-1U-10 (AS4777-2 2020)

5 kW · 1φ

GEP5.0-1-10 (AS4777-2 2020)

5 kW · 1φ

GEP5.0-1-10 (AS4777-2 2020)

5 kW · 1φ

GEP5.0-1-30 (AS4777-2 2020)

5 kW · 1φ

GEP5.0-1C-10 (AS4777-2 2020)

5 kW · 1φ

GEP5.0-1C-30 (AS4777-2 2020)

5 kW · 1φ

View all GoodWe Technologies Co Ltd inverters

More from GoodWe

Other CEC-approved products from GoodWe available in Australia.

GoodWe Batteries

GW100KWH-D-10

100.8 kWh · LFP

GW102.4-BAT-AC-G10

100 kWh · LFP

GW112.6-BAT-AC-G10

110 kWh · LFP

GW5.1-BAT-D-G20

5 kWh · LFP

GW5.1-BAT-D-G21

5 kWh · LFP

GW6.0-BAT-D-G20

5.9 kWh · LFP

View all GoodWe batteries

GoodWe Solar Panels

BMM-T3/108A(505W)

505W

BMM-T3/108A(510W)

510W

BMM-T3/108A(515W)

515W

BMM-T3/120A(565W)

565W

BMM-T3/120A(570W)

570W

BMM-T3/120A(575W)

575W

View all GoodWe panels
View full GoodWe manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?