Solar inverter · GoodWe · CEC approved September 2025
CEC listing: GW4200-DNS-30 (AS4777-2 2020)
A 4.2 kW single-phase solar inverter.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the GoodWe GW4200-DNS-30, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 97.9% |
| European efficiency | 97% |
| DC input & MPPT | |
| MPPT trackers | 2 |
| Physical | |
| IP rating | IP66 |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
www.goodwe.com.auThe GoodWe GW4200-DNS-30 against the closest-power inverters from other brands.
| Specification | GoodWe GW4200-DNS-30GoodWe | Beijing Hua Xin Liu He Investment Z20I4K2D-2Beijing Hua Xin Liu He Investment | Beijing Hua Xin Liu He Investment Z20I4K2DBeijing Hua Xin Liu He Investment |
|---|---|---|---|
| Rated power? | 4.2 kW | 4.2 kW | 4.2 kW |
| Max efficiency? | 97.9% | Not on file | Not on file |
| MPPT trackers? | 2 | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Single-phase |
| Type | Solar | Solar | Solar |
| Battery ready | No | No | No |
| Warranty | 20 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers hardware costs, including spare parts or unit replacement, at Goodwe’s discretion. Exclusions include non-accredited installations and modifications, and to make a claim, contact your regional sales representative.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 5 of 5. The official install manual is the authoritative source — always confirm before acting.
Grid Frequency InstabilitywarningCall your installerUtility grid exception. The actual grid frequency change rate does not meet the requirement of the local grid standard.
Grid OvervoltagewarningCall your installerThe grid voltage exceeds the permissible range or the duration of high voltage exceeds the requirement of HVRT.
Grid Rapid OvervoltagewarningCall your installerThe grid voltage is abnormal or ultra-high.
Grid UndervoltagewarningCall your installerThe grid voltage is lower than the permissible range, or the duration of low voltage exceeds the requirement of LVRT.
Utility LosswarningUtility grid power fails or AC cable is disconnected, or the AC breaker is off.
GEP4.2-1-10 (AS4777-2 2020)
4.2 kW · 1φ
GEP4.2-1-10 (AS4777-2 2020)
4.2 kW · 1φ
GEP4.2-1-30 (AS4777-2 2020)
4.2 kW · 1φ
GW4.2K-DNS-G40 (AS4777-2 2020)
4.2 kW · 1φ
GW4200D-NS (AS4777-2 2020)
4.2 kW · 1φ
GW4200T-DS (AS4777-2 2020)
4.2 kW · 1φ
Other CEC-approved products from GoodWe available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.