Loading Solar Battery Perth...
Loading Solar Battery Perth...
Solar inverter · GoodWe · SDT G2 series · CEC approved July 2026
CEC listing: GW4000-SDT-20 (AS4777-2 2020)
A 4 kW three-phase solar inverter.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Rated power
How much solar it can turn into usable power at once
Max efficiency
How much of the solar you make reaches the house
Phases
Needs a three-phase supply — check your switchboard
Type
Runs solar only
Warranty
How long GoodWe Technologies Co Ltd stands behind it
Every figure on file for the GoodWe GW4000-SDT-20, by section.
| Specification | Value |
|---|---|
| Efficiency | |
| Max efficiency | 98.2% |
| European efficiency | 97.6% |
| Physical | |
| IP rating | IP65 |
| Installation requirements | |
| Top clearance | 100 mm |
| Side clearance | 100 mm |
| AC breaker | 25 A |
| Cable gauge | 6 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | Yes |
| Estimated install time | 8 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Battery compatible
No
Backup capable
No
CEC approved
28 July 2026
Approval expiry
31 Oct 2026
Status
Active
Eligible for rebates
Yes
Years in AU Market
12 years
Australian Office
Yes
CEC-Approved Batteries
30
CEC-Approved Panels
168
Category
Mid-Tier
Typical installed, inverter only
$800–$1,600
Prices vary by installer, configuration and site complexity. Get exact quotes from installers you choose.
Compare quotes from installers you choose
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead — ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
www.goodwe.com.auThe GoodWe GW4000-SDT-20 against the closest-power inverters from other brands.
| Specification | GoodWe GW4000-SDT-20GoodWe | Afore New Energy Technology AF4K-SLAfore New Energy Technology | Afore New Energy Technology HNS4000TLAfore New Energy Technology |
|---|---|---|---|
| Rated power? | 4 kW | 4 kW | 4 kW |
| Max efficiency? | 98.2%best value | 0.0% | 0.0% |
| MPPT trackers? | Not verified | Not verified | Not verified |
| Phases | Three-phase | Single-phase | Single-phase |
| Type | Solar | Hybrid | Solar |
| Battery ready | No | Yes | No |
| Warranty | 10 years | Not verified | Not verified |
Specs from the CEC register and datasheet enrichment. Indicative — confirm exact figures with your installer.
GOODWE offers a limited 10-year warranty on inverters, covering hardware defects and transportation costs for valid claims. Warranty voids for improper installation or environmental damage. Claims can be submitted through your local distributor or online.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.
13criticalCall your installerARC Fault
14criticalCall your installerDC Bus High
2criticalCall your installerUtility Loss
5criticalCall your installerIsolation Fail
8criticalCall your installerPV Over Voltage
DC Bus HighcriticalCall your installerInverter internal fault.
Isolation FailcriticalCall your installerThe PV system is short-circuited to the ground or in a moist environment.
PV Over VoltagecriticalCall your installerExcess PV modules are connected in series causing high open-circuit voltage.
Relay Check FailcriticalCall your installerRelay operation check failed.
Utility LosscriticalCall your installerUtility grid power failure.
Ver. ErrorcriticalCall your installerWrong software version.
1warningCall your installerVersion Error
10warningCall your installerA Fan Fail
11warningCall your installerE Fan Fail
12warningCall your installerI Fan Fail
3warningCall your installerVac Fail
4warningCall your installerFac Fail
6warningCall your installerDC Inject High
7warningCall your installerGround I Fail
9warningCall your installerOver Temperature
ARC FaultwarningThe PV string cables arc or are in poor contact.
DC inject HighwarningDC injection exceeds the allowed range.
Fac FailwarningThe utility grid frequency is out of the allowed range.
Ground I FailwarningThe input insulation impedance to the ground decreases when the inverter is operating.
Over TemperaturewarningThe inverter is overheating due to poor ventilation or high ambient temperature.
Vac FailwarningThe utility grid voltage is out of the allowed range.
AFan FailinfoA fault occurs in all fans of the inverter.
EFan FailinfoA fault occurs on the external fan of the inverter.
IFan FailinfoCall your installerA fault occurs in the internal fan of the inverter.
Part of the GoodWe SDT G2 series
Compare every GoodWe SDT G2 variant side by side →
GEH10-1U-10 (AS4777-2 2020)
10 kW · 1φ
GEH15-3U-10 (AS4777-2 2020)
15 kW · 1φ
GEH20-3U-10 (AS4777-2 2020)
20 kW · 1φ
GEH25-3U-10 (AS4777-2 2020)
25 kW · 1φ
GEH29.9-3U-10 (AS4777-2 2020)
29.9 kW · 1φ
GEH5.0-1U-10 (AS4777-2 2020)
5 kW · 1φ
Other CEC-approved products from GoodWe Technologies Co Ltd available in Australia.
GW100KWH-D-10
100.8 kWh · LFP
GW102.4-BAT-AC-G10
100 kWh · LFP
GW112.6-BAT-AC-G10
110 kWh · LFP
GW5.1-BAT-D-G20
5 kWh · LFP
GW5.1-BAT-D-G21
5 kWh · LFP
GW6.0-BAT-D-G20
5.9 kWh · LFP
BMM-T3/108A(505W) (IEC 61215-2021)
505W
BMM-T3/108A(510W) (IEC 61215-2021)
510W
BMM-T3/108A(515W) (IEC 61215-2021)
515W
BMM-T3/120A(565W) (IEC 61215-2021)
565W
BMM-T3/120A(570W) (IEC 61215-2021)
570W
BMM-T3/120A(575W) (IEC 61215-2021)
575W
Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.