Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. GoodWe
  4. GW4000-SDT-20

Solar inverter · GoodWe · CEC approval expired

GoodWe GW4000-SDT-20

CEC listing: GW4000-SDT-20 (AS4777-2 2020)

A 4 kW three-phase solar inverter.

Rated power
4kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

GW4000-SDT-20: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
4kW
How much solar it can turn into usable power at once
Max efficiency
98.2%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Solar
Runs solar only
Warranty
10yr
How long GoodWe Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the GoodWe GW4000-SDT-20, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.2%
European efficiency97.6%
Physical
IP ratingIP65
Installation requirements
Top clearance100 mm
Side clearance100 mm
AC breaker25 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
28 July 2026
Approval expiry
31 Oct 2026
Status
Not listed
Listed for STCs
No (not listed)

About GoodWe

Years on the CEC list
12 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
229
CEC-approved batteries
30
CEC-approved panels
168
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • GoodWe Technologies Co Ltd batteries and panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
17.0 kWh
Annual yield
6,205 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.goodwe.com.au
12 years on the CEC list

How it compares

The GoodWe GW4000-SDT-20 against the closest-power inverters from other brands.

Specification
GoodWe GW4000-SDT-20GoodWe
Afore AF4K-SLAfore
Afore HNS4000TLAfore
Rated power?4 kW4 kW4 kW
Max efficiency?98.2%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and installation guide and user manualPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

GoodWe GW4000-SDT-20

GOODWE offers a limited 10-year warranty on inverters, covering hardware defects and transportation costs for valid claims. Warranty voids for improper installation or environmental damage. Claims can be submitted through your local distributor or online.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, tampering, operational failure not reported within one month, and usage against safety regulations.
Environment limits
Faults or damage caused by exposure to sea coasts/saltwater or other aggressive environments without written approval from GOODWE.
Read the official warranty document (PDF)

Fault & error codes — GoodWe GW4000-SDT-20

From the install manual

29 documented

Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.

  • 13criticalCall your installer
    Manual (PDF)

    ARC Fault

    Likely cause
    The PV string cables arc or are in poor contact.
    What to do
    Check whether the PV terminals and cables are connected properly.
  • 14criticalCall your installer
    Manual (PDF)

    DC Bus High

    Likely cause
    Inverter internal fault.
    What to do
    Restart the inverter to check whether the inverter can work properly.
  • 2criticalCall your installer
    Manual (PDF)

    Utility Loss

    Likely cause
    1. Utility grid power failure. 2. The AC circuit or the AC breaker is disconnected.
    What to do
    Check whether other electrical devices under the same grid connection point are working normally and whether the main supply is normal.
  • 5criticalCall your installer
    Manual (PDF)

    Isolation Fail

    Likely cause
    1. The PV system is short-circuited to the ground. 2. The PV system is in a moist environment and the circuit is not well insulated to the ground.
    What to do
    Check whether the PV input cables are broken.
  • 8criticalCall your installer
    Manual (PDF)

    PV Over Voltage

    Likely cause
    Excess PV modules are connected in the series, and the open-circuit voltage is higher than the operating voltage.
    What to do
    Check whether the PV string voltage meets the maximum input voltage requirements.
  • DC Bus HighcriticalCall your installer
    Manual (PDF)

    Inverter internal fault.

    Likely cause
    Check software version and function.
    What to do
    Restart the inverter to check functionality.
  • Isolation FailcriticalCall your installer
    Manual (PDF)

    The PV system is short-circuited to the ground or in a moist environment.

    Likely cause
    Check PV input cables and grounding.
    What to do
    Check for breaks in cables and grounding.
  • PV Over VoltagecriticalCall your installer
    Manual (PDF)

    Excess PV modules are connected in series causing high open-circuit voltage.

    Likely cause
    Check PV string input voltage.
    What to do
    Ensure that the PV string voltage meets the maximum input voltage requirements.
  • Relay Check FailcriticalCall your installer
    Manual (PDF)

    Relay operation check failed.

    Likely cause
    Internal relay issue.
    What to do
    Contact after-sales service immediately.
  • Utility LosscriticalCall your installer
    Manual (PDF)

    Utility grid power failure.

    Likely cause
    1. Check whether other electrical devices under the same grid connection point are working normally and whether the main supply is normal. 2. Make sure that the upstream switches of the inverter are connected. 3. Make sure that the phase sequence of the AC cables is connected correctly, and the neutral wire and PE cable are connected properly and firmly.
    What to do
    Check electrical devices and connections.
  • Ver. ErrorcriticalCall your installer
    Manual (PDF)

    Wrong software version.

    Likely cause
    Contact after-sales service to upgrade the software.
    What to do
    Contact after-sales service to upgrade the software.
  • 1warningCall your installer
    Manual (PDF)

    Version Error

    Likely cause
    Wrong software version.
    What to do
    Contact after-sales service to upgrade the software.
  • 10warningCall your installer
    Manual (PDF)

    A Fan Fail

    Likely cause
    A fault occurs in all fans of the inverter.
    What to do
    Restart the inverter and check whether the inverter can work normally.
  • 11warningCall your installer
    Manual (PDF)

    E Fan Fail

    Likely cause
    A fault occurs on the external fan of the inverter.
    What to do
    Contact after-sales service.
  • 12warningCall your installer
    Manual (PDF)

    I Fan Fail

    Likely cause
    A fault occurs in the internal fan of the inverter.
    What to do
    Contact after-sales service.
  • 3warningCall your installer
    Manual (PDF)

    Vac Fail

    Likely cause
    The utility grid voltage is out of the allowed range.
    What to do
    Make sure that the grid voltage is within the allowed range.
  • 4warningCall your installer
    Manual (PDF)

    Fac Fail

    Likely cause
    The utility grid frequency is out of the allowed range.
    What to do
    Check whether other electrical devices under the same grid connection point are working normally, and whether the main supply is normal.
  • 6warningCall your installer
    Manual (PDF)

    DC Inject High

    Likely cause
    DC injection exceeds the allowed range.
    What to do
    Check whether the software version is the latest one.
  • 7warningCall your installer
    Manual (PDF)

    Ground I Fail

    Likely cause
    The input insulation impedance to the ground decreases when the inverter is operating.
    What to do
    Make sure that the components are properly grounded and the AC side is properly grounded.
  • 9warningCall your installer
    Manual (PDF)

    Over Temperature

    Likely cause
    1. The inverter is installed in a place with poor ventilation. 2. The ambient temperature is too high.
    What to do
    Check the installation environment and space of the inverter. Make sure that the ventilation meets heat dissipation requirements.
  • ARC Faultwarning
    Manual (PDF)

    The PV string cables arc or are in poor contact.

    Likely cause
    Check cable connections.
    What to do
    Check PV cables and clear error messages.
  • DC inject Highwarning
    Manual (PDF)

    DC injection exceeds the allowed range.

    Likely cause
    Check if voltage is within specifications.
    What to do
    Check if the software version is the latest one.
  • Fac Failwarning
    Manual (PDF)

    The utility grid frequency is out of the allowed range.

    Likely cause
    Frequency could vary; check if other devices on grid are okay.
    What to do
    Check if the grid frequency is within the allowed range.
  • Ground I Failwarning
    Manual (PDF)

    The input insulation impedance to the ground decreases when the inverter is operating.

    Likely cause
    High humidity or poor grounding.
    What to do
    Make sure that components are grounded properly.
  • Over Temperaturewarning
    Manual (PDF)

    The inverter is overheating due to poor ventilation or high ambient temperature.

    Likely cause
    Ensure good ventilated space for inverter operation.
    What to do
    Check installation environment and space for ventilation.
  • Vac Failwarning
    Manual (PDF)

    The utility grid voltage is out of the allowed range.

    Likely cause
    Check the grid voltage and wiring.
    What to do
    Make sure that the grid voltage is within the allowed range.
  • AFan Failinfo
    Manual (PDF)

    A fault occurs in all fans of the inverter.

    Likely cause
    Check fan operation.
    What to do
    Restart inverter and check fan functionality.
  • EFan Failinfo
    Manual (PDF)

    A fault occurs on the external fan of the inverter.

    Likely cause
    Check the external fan.
    What to do
    Restart inverter to check if it works now.
  • IFan FailinfoCall your installer
    Manual (PDF)

    A fault occurs in the internal fan of the inverter.

    Likely cause
    Check internal fan operation.
    What to do
    Contact after-sales service if the fault persists.

More GoodWe Technologies Co Ltd inverters

GEP5.0-3-10 (AS4777-2 2020)

5 kW · 3φ

GW5000-SDT-20 (AS4777-2 2020)

5 kW · 3φ

GW5000-SDT-AU30 (AS4777-2 2020)

5 kW · 3φ

GW5K-BTA-G20 (AS4777-2 2020)

5 kW · 3φ

GW5K-ETA-G20 (AS4777-2 2020)

5 kW · 3φ

GW5KL-ET (AS4777-2 2020)

5 kW · 3φ

View all GoodWe Technologies Co Ltd inverters

More from GoodWe

Other CEC-approved products from GoodWe available in Australia.

GoodWe Batteries

GW100KWH-D-10

100.8 kWh · LFP

GW102.4-BAT-AC-G10

100 kWh · LFP

GW112.6-BAT-AC-G10

110 kWh · LFP

GW5.1-BAT-D-G20

5 kWh · LFP

GW5.1-BAT-D-G21

5 kWh · LFP

GW6.0-BAT-D-G20

5.9 kWh · LFP

View all GoodWe batteries

GoodWe Solar Panels

BMM-T3/108A(505W)

505W

BMM-T3/108A(510W)

510W

BMM-T3/108A(515W)

515W

BMM-T3/120A(565W)

565W

BMM-T3/120A(570W)

570W

BMM-T3/120A(575W)

575W

View all GoodWe panels
View full GoodWe manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?