Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Rated Power
10 kW
Max Efficiency
98.2%
Phases
Three Phase
Max Input Voltage
—
Min Input Voltage
—
Max Input Current
—
Output Voltage
—
Max Output Current
—
Country of Origin
Unknown
Series
SDT G2
MPPT Trackers
2
European Efficiency
97.6%
Warranty
5 years
Dimensions
0 x 0 x 0 mm
IP Rating
IP65
Operating Temp
-25°C to 60°C
Cooling
Natural
Battery Compatible
No
Backup Capable
No
ESM Compliant
No
Black Start
No
Grid Forming
No
Export Limiting
No
Remote Monitoring
No
CEC Approved
28 Aug 2025
Approval Expiry
30 Sept 2026
Status
Active
Eligible for Rebates
Yes
Years in AU Market
12 years
Australian Office
Yes
CEC-Approved Batteries
30
CEC-Approved Panels
0
Category
Mid-Tier
$2,000–$4,000
Perth installed price estimate · medium confidence
Prices vary by installer, configuration, and site complexity. Get exact quotes via our installer matching.
From May 1, 2026, all new battery installations in WA require CSIP-AUS compliant inverters. Verify ESM status with your installer.
Perth's high ambient temperatures (regularly 35°C+) can reduce inverter efficiency and trigger thermal throttling. For installations in direct sun or non-ventilated garages, consider inverters with active cooling and wide operating temperature ranges. All grid-connected installations require Western Power approval. Systems above 5kVA require ESM compliance under WA regulations.
Compare this inverter with batteries for a complete system analysis
Based on 5 PSH/day (BOM) with 15% system derate.
Australian office
Has local presence
Website
au.goodwe.comThe GoodWe Technologies Co Ltd GW10KAU-DT (AS4777-2 2020) against the closest-power inverters from other brands.
| Specification | GoodWe Technologies Co Ltd GW10KAU-DT (AS4777-2 2020)GoodWe Technologies Co Ltd | 8 Star Energy Pty Ltd Force 10.0HS+ (AS4777-2 2020)8 Star Energy Pty Ltd | 8 Star Energy Pty Ltd Force 10.0HT+ (AS4777-2 2020)8 Star Energy Pty Ltd |
|---|---|---|---|
| Rated power? | 10 kW | 10 kW | 10 kW |
| Max efficiency? | 98.2%best value | 0.0% | 0.0% |
| MPPT trackers? | 2 | Not verified | Not verified |
| Phases | Three-phase | Single-phase | Three-phase |
| Type | Solar | Hybrid | Hybrid |
| Battery ready | No | Yes | Yes |
| Warranty | 5 years | Not verified | Not verified |
Specs from the CEC register and datasheet enrichment. Indicative — confirm exact figures with your installer.
This warranty covers defects in materials and workmanship for five years. It excludes damages resulting from improper installation or modifications. For claims, contact the manufacturer with your purchase information.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 15 of 15. The official install manual is the authoritative source — always confirm before acting.
DC Bus HighcriticalCall your installerInverter internal fault.
Isolation FailcriticalCall your installerThe PV system is short-circuited to the ground or in a moist environment.
PV Over VoltagecriticalCall your installerExcess PV modules are connected in series causing high open-circuit voltage.
Relay Check FailcriticalCall your installerRelay operation check failed.
Utility LosscriticalCall your installerUtility grid power failure.
Ver. ErrorcriticalCall your installerWrong software version.
ARC FaultwarningThe PV string cables arc or are in poor contact.
DC inject HighwarningDC injection exceeds the allowed range.
Fac FailwarningThe utility grid frequency is out of the allowed range.
Ground I FailwarningThe input insulation impedance to the ground decreases when the inverter is operating.
Over TemperaturewarningThe inverter is overheating due to poor ventilation or high ambient temperature.
Vac FailwarningThe utility grid voltage is out of the allowed range.
AFan FailinfoA fault occurs in all fans of the inverter.
EFan FailinfoA fault occurs on the external fan of the inverter.
IFan FailinfoCall your installerA fault occurs in the internal fan of the inverter.
Part of the GoodWe Technologies Co Ltd SDT G2 series
Compare every GoodWe Technologies Co Ltd SDT G2 variant side by side →
GEH10-1U-10 (AS4777-2 2020)
10 kW · 1φ
GEH15-3U-10 (AS4777-2 2020)
15 kW · 1φ
GEH20-3U-10 (AS4777-2 2020)
20 kW · 1φ
GEH25-3U-10 (AS4777-2 2020)
25 kW · 1φ
GEH29.9-3U-10 (AS4777-2 2020)
29.9 kW · 1φ
GEH5.0-1U-10 (AS4777-2 2020)
5 kW · 1φ
Other CEC-approved products from GoodWe Technologies Co Ltd available in Australia.
Compare quotes from SAA-accredited local installers — you choose which to act on. No obligation, no pressure.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.