Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Solis
  4. Solis-mini-2000-4G

Solar inverter · Solis · CEC approved July 2024

Solis Solis-mini-2000-4G

CEC listing: Solis-mini-2000-4G (AS4777-2 2020)

A 2 kW single-phase solar inverter.

Rated power
2kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Solis-mini-2000-4G: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
2kW
How much solar it can turn into usable power at once
Max efficiency
96.6%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
6yr
How long Ginlong Technologies Co Ltd stands behind it

Full datasheet

Every figure on file for the Solis Solis-mini-2000-4G, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency96.6%
Physical
Weight7.4 kg
IP ratingIP65
Installation requirements
Cable gauge6 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
27 July 2024
Approval expiry
31 Dec 2026
Status
Active
Listed for STCs
Yes

About Solis

Years on the CEC list
5 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
144
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Browse CEC-approved panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
8.5 kWh
Annual yield
3,103 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.solisinverters.au
5 years on the CEC list

How it compares

The Solis Solis-mini-2000-4G against the closest-power inverters from other brands.

Specification
Solis Solis-mini-2000-4GSolis
Altenergy Power System DS3D-HAltenergy Power System
Altenergy Power System DS3D-HAltenergy Power System
Rated power?2 kW2 kW2 kW
Max efficiency?96.6%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarSolarSolar
Battery readyNoNoNo
Warranty6 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manual and compliance certificatePDF, opens in a new tab

6-year inverter warranty

Solis Solis-mini-2000-4G

The warranty covers manufacturing defects for 5 years and can be extended to 20 years. To make a claim, provide the inverter's serial number and contact the manufacturer, Ginlong Technologies.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, and incorrect operation. Damage from reverse DC connection or exceeding specified input voltage.
Read the official warranty document (PDF)

Fault & error codes — Solis Solis-mini-2000-4G

From the install manual

7 documented

Showing 7 of 7. The official install manual is the authoritative source — always confirm before acting.

  • ARCI-FAULTcriticalCall your installer
    Manual (PDF)

    Arc fault detected

    Likely cause
    Potential arc detected in DC circuit.
    What to do
    Check inverter connections for any signs of arcing and restart inverter.
  • INI-FAULTcriticalCall your installer
    Manual (PDF)

    Initialization system fault

    Likely cause
    Checks on main board or power board connections are needed.
    What to do
    Restart inverter or contact installer.
  • NO-GRIDcriticalCall your installer
    Manual (PDF)

    No grid voltage

    Likely cause
    Disconnection or failure in grid connection.
    What to do
    Check connections and grid switch. Ensure grid voltage is present.
  • PV ISO-PRO01criticalCall your installer
    Manual (PDF)

    PV isolation protection fault - Level 1

    Likely cause
    Isolation fault detected on the PV side.
    What to do
    Remove all DC input, reconnect and restart inverter one by one to isolate the issue.
  • OV-DC01warningCall your installer
    Manual (PDF)

    Over DC voltage - Level 1

    Likely cause
    Too many modules connected in series.
    What to do
    Reduce the number of modules in series.
  • OV-G-V01warningCall your installer
    Manual (PDF)

    Over grid voltage - Level 1

    Likely cause
    Resistant of AC cable is too high. Change bigger size grid cable.
    What to do
    Adjust the protection limit if it's allowed by electrical company.
  • UN-G-V01warning
    Manual (PDF)

    Under grid voltage - Level 1

    Likely cause
    Low grid voltage detected.
    What to do
    Use user-defined function to adjust the protection limit if allowed by electrical company.

More Ginlong Technologies Co Ltd inverters

S5-GR1P2K-M (AS4777-2 2020)

2 kW · 1φ

S5-GR1P1.5K-M (AS4777-2 2020)

1.5 kW · 1φ

Solis-mini-1500-4G (AS4777-2 2020)

1.5 kW · 1φ

S5-GR1P2.5K-M (AS4777-2 2020)

2.5 kW · 1φ

Solis-mini-2500-4G (AS4777-2 2020)

2.5 kW · 1φ

S5-GR1P1K-M (AS4777-2 2020)

1 kW · 1φ

View all Ginlong Technologies Co Ltd inverters

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?