Hybrid inverter · Solis · CEC approval expired
CEC listing: RHI-3P8K-HVES-5G (AS4777-2 2020)
An 8 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Every figure on file for the Solis RHI-3P8K-HVES-5G, by section.
| Specification | Value |
|---|---|
| Power & output | |
| Nominal power | 8 kW |
| Maximum power | 8 kW |
| Apparent power | 8 kVA |
| Phases | 3 |
| Efficiency | |
| Max efficiency | 98.4% |
| European efficiency | 97.7% |
| CEC-weighted efficiency | 99.9% |
| DC input & MPPT | |
| MPPT trackers | 2 |
| Max input voltage | 1000 V |
| MPPT voltage min | 200 V |
| MPPT voltage max | 850 V |
| Max input current | 26 A |
| Battery & backup | |
| Battery compatible | Yes |
| Backup capable | Yes |
| Continuous backup | 8 kW |
| Physical | |
| Dimensions (H×W×D) | 455 × 535 × 185 mm |
| Weight | 25.1 kg |
| IP rating | IP65 |
| Cooling | Natural convection |
| Operating temperature | -25°C to 60°C |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| Cable gauge | 4 mm² |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
www.solisinverters.auThe Solis RHI-3P8K-HVES-5G against the closest-power inverters from other brands.
| Specification | Energizer Force 8.0HS+Energizer | Energizer Force 8.0HT+Energizer | |
|---|---|---|---|
| Rated power? | 8 kW | 8 kW | 8 kW |
| Max efficiency? | 98.4% | Not on file | Not on file |
| MPPT trackers? | 2 | Not on file | Not on file |
| Phases | Three-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 5 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
The warranty covers defects in materials and workmanship for a duration of 5 years, which can be extended up to 20 years. It does not cover damage from improper installation or modifications, and customers must contact Solis for claims.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 34 of 34. The official install manual is the authoritative source — always confirm before acting.
12Power-FAULTcriticalCall your installer12V power supply fault
ARC-FAULTcriticalARC detected in DC circuit
DC-INTFcriticalCall your installerDC input overcurrent
DCinj-FAULTcriticalCall your installerHigh DC injection current
DSP-B-FAULTcriticalCall your installerComm. failure between main and slave DSP
IGBT-OV-IcriticalCall your installerOver IGBT current
ILeak-PRO 01/02/03/04criticalCall your installerLeakage current protection
INI-FAULTcriticalCall your installerInitialization system fault
LCD show initializing all the timecriticalCall your installerCannot start-up
No powercriticalCall your installerInverter no power on LCD
NO-GRIDcriticalCall your installerNo grid voltage
OV-BUScriticalCall your installerOver DC bus voltage
OV-DC01/02/03/04criticalCall your installerOver DC voltage
OV-DCA-IcriticalCall your installerDC input overcurrent
OV-G-IcriticalCall your installerOver grid current
OV-G-V01/02/03/04criticalCall your installerOver grid voltage
OV-IgTrcriticalCall your installerAC side transient overcurrent
OV-ILLCcriticalCall your installerLLC hardware overcurrent
OV-TEMcriticalCall your installerOver Temperature
OV-VBackupcriticalCall your installerBypass overvoltage fault
OV-Vbatt-HcriticalCall your installerBattery overvoltage hardware fault
OV-Vbatt1criticalCall your installerBattery overvoltage detected
Over-LoadcriticalCall your installerBypass overload fault
PV ISO-PRO01/02criticalCall your installerPV isolation protection
RelayChk-FAILcriticalCall your installerRelay check failed
AFCI Check FAULTwarningCall your installerAFCI module self check fault
G-IMPwarningHigh grid impedance
GRID-INTF01/02warningCall your installerGrid interference
IGFOL-FwarningCall your installerGrid current tracking fail
NO-BatterywarningUnconnected battery
OV-G-F01/02warningOver grid frequency
UN-BUS01/02warningCall your installerUnder DC bus voltage
UN-G-F01/02warningUnder grid frequency
UN-G-V01/02warningUnder grid voltage
S5-GR3P8K-AU (AS4777-2 2020)
8 kW · 3φ
S6-EH3P8K-H-AU (AS4777-2 2020)
8 kW · 3φ
S6-EH3P8K02-NV-YD-L-AU (AS4777-2 2020)
8 kW · 3φ
S6-GR3P8K03-NV-ND-AU (AS4777-2 2020)
8 kW · 3φ
S5-GR3P9K-AU (AS4777-2 2020)
9 kW · 3φ
S6-GR3P9K03-NV-ND-AU (AS4777-2 2020)
9 kW · 3φ
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.