Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Alpha ESS
  4. SMILE-G3-T20-INV

Hybrid inverter · Alpha ESS · CEC approved June 2026

Alpha ESS SMILE-G3-T20-INV

CEC listing: SMILE-G3-T20-INV (AS4777-2 2020)

A 20 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
20kWHow much solar it can run at once: a large roof
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SMILE-G3-T20-INV: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
20kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Alpha ESS Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Alpha ESS SMILE-G3-T20-INV, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP65
Operating temperature-25°C to 60°C
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance100 mm
AC breaker32 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
15 June 2026
Approval expiry
15 June 2029
Status
Active
Listed for STCs
Yes

About Alpha ESS

Years on the CEC list
9 years
Australian office
Yes
Category
Mid-Tier
CEC-approved inverters
43
CEC-approved batteries
76
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Australian office

Has local presence

Website

alphaess.au
9 years on the CEC list

How it compares

The Alpha ESS SMILE-G3-T20-INV against the closest-power inverters from other brands.

Specification
Alpha ESS SMILE-G3-T20-INVAlpha ESS
Afore AF20K-THAfore
Solplanet ASW020K-THSolplanet
Rated power?20 kW20 kW20 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseThree-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and compliance certificatePDF, opens in a new tab
  • User manualPDF, opens in a new tab

10-year inverter warranty

Alpha ESS SMILE-G3-T20-INV

This warranty covers product and performance for 10 years. It excludes damage from non-accredited installation. To make a claim, contact support with details.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voided if installed by non-accredited installers or if modified.
Environment limits
Operating Temperature Range: -10°C ~ 50°C for one module and -10°C ~ 60°C for another.
Read the official warranty document (PDF)

Fault & error codes — Alpha ESS SMILE-G3-T20-INV

From the install manual

14 documented

Showing 14 of 14. The official install manual is the authoritative source — always confirm before acting.

  • 100000criticalCall your installer
    Manual (PDF)

    Grid overvoltage

    Likely cause
    Check whether the Grid is abnormal or if the cable connection is faulty.
    What to do
    Inspect grid conditions and connections; restart inverter to check if fault persists.
  • 100001criticalCall your installer
    Manual (PDF)

    Grid undervoltage

    Likely cause
    Check grid voltage; may be too low.
    What to do
    Monitor grid voltage; contact utility if the problem persists.
  • 100003criticalCall your installer
    Manual (PDF)

    Grid under frequency

    Likely cause
    Check grid frequency; it may be too low.
    What to do
    Monitor grid frequency; contact utility if the problem persists.
  • 100006criticalCall your installer
    Manual (PDF)

    Grid fault

    Likely cause
    Check if the grid connection is stable.
    What to do
    Inspect grid connections; if issues persist, contact the installer.
  • 100009criticalCall your installer
    Manual (PDF)

    Leakage current test failure

    Likely cause
    Possible insulation issues.
    What to do
    Check for ground faults and measure insulation resistance; contact installer.
  • 100010criticalCall your installer
    Manual (PDF)

    Grid relay fault

    Likely cause
    Check installation and grid connections.
    What to do
    Inspect grid and installation; contact installer if unresolved.
  • 100011criticalCall your installer
    Manual (PDF)

    Over_Temperature

    Likely cause
    The inverter is overheating.
    What to do
    Check the environment around the inverter to ensure proper ventilation. Power off to cool down. If the error persists, contact customer service.
  • 60004criticalCall your installer
    Manual (PDF)

    Follower_Battery_Communication_Lost

    Likely cause
    Communication cables between batteries are disconnected.
    What to do
    Check the communication cables between batteries. If the error persists, contact customer service for further check.
  • 60006criticalCall your installer
    Manual (PDF)

    Host_Battery_Communication_Lost

    Likely cause
    Communication cables are disrupted between the main battery and inverter.
    What to do
    Ensure the communication connection between the inverter and main battery is intact. If the issue remains, contact customer service.
  • 60008criticalCall your installer
    Manual (PDF)

    Multi_Host_error

    Likely cause
    Multiple hosts detected in the system.
    What to do
    Check configurations to ensure only one host is enabled. If the error persists, contact customer service.
  • 100002warning
    Manual (PDF)

    Grid_OFP

    Likely cause
    Grid over frequency protection triggered.
    What to do
    Check whether the grid frequency is within the accepted range. If not, wait and check back. If the error persists, contact customer service.
  • 100012warningCall your installer
    Manual (PDF)

    PV reverse connection

    Likely cause
    Check if PV connections are reversed.
    What to do
    Inspect PV connections.
  • 100013warningCall your installer
    Manual (PDF)

    Battery reverse connection

    Likely cause
    Check if battery connections are reversed.
    What to do
    Inspect battery connections.
  • 60002warningCall your installer
    Manual (PDF)

    Circuit_Breaker_Open

    Likely cause
    Battery circuit breaker is turned off.
    What to do
    Try to switch on all batteries’ circuit breakers. If the error persists, contact customer service for further check.

More Alpha ESS Co Ltd inverters

SMILE-G3-T15-INV (AS4777-2 2020)

15 kW · 3φ

SMILE-T10-HV-INV (AS4777-2 2020)

10 kW · 3φ

M30-INV-AU (AS4777-2 2020)

30 kW · 3φ

SMILE-G3-T10-INV (AS4777-2 2020)

9.999 kW · 3φ

SMILE-G3-T5-INV (AS4777-2 2020)

5 kW · 3φ

M50-INV-AU (AS4777-2 2020)

50 kW · 3φ

View all Alpha ESS Co Ltd inverters

More from Alpha ESS

Other CEC-approved products from Alpha ESS available in Australia.

Alpha ESS Batteries

M38314-108SNW

97.61 kWh · LFP

M38314-120SNW

108.45 kWh · LFP

M38314-132SNW

119.3 kWh · LFP

M38314-144SNW

130.14 kWh · LFP

M38314-156SNW

140.99 kWh · LFP

M38314-168SNW

151.83 kWh · LFP

View all Alpha ESS batteries
View full Alpha ESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?