Home battery · Solinteg · CEC approved November 2026
Solinteg E2BR-S112K-C-Neo
A 101.25 kWh home battery. Very big home size, the 40+ kWh band.
- WA Battery Scheme rebate
- Depends on your inverter
- The battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
- Usable capacity
- 101.25kWh
- Warranty
- 10yrs
What it costs in Perth
We price batteries by size rather than by model. The average installed price before rebates:
- 10 kWh
- $7,000–$9,000
- 20 kWh
- $10,000–$15,000
Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.
Rebates on this battery
- WA Battery Scheme
- Depends on your inverter
- Federal STCs
- −$6,943
The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.
Key specs, in plain terms
The numbers that matter for a home. The full datasheet is below.
- Usable capacity
- 101.25kWh
- How much energy it stores for you to use
- Continuous power
- Not on file: we don't have this figure from the manufacturer's documents yet
- How much it can run at once
- Round-trip efficiency
- Not on file: we don't have this figure from the manufacturer's documents yet
- How much of the energy you store comes back out
- Warranty
- 10yr
- How long the manufacturer stands behind it
- Battery chemistry
- LFP
- Lithium iron phosphate, the long-cycle-life type
Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us
What we can tell you
Read from the figures on this page. No review written yet.
- 101.25 kWh sits in the very big home band (40+ kWh).
- It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.
- We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.
Warranty and support
This warranty covers defects for 10 years, with 85% capacity assured through year 10. Modifications invalidate coverage. Claims can be made through the Solinteg website.
- Product
- 10 years; transferable; pro-rata
- Throughput
- 30 MWh
- Installation
- Must be installed by an SAA-accredited installer
- Support
- Not verifiedWe have not verified this brand's Australian support structure. Confirm warranty arrangements with the manufacturer or your installer.
WA Battery Scheme eligibility
ConditionalWhether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.
This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery in a same-brand, same-platform setup with more than one unit. Without one, exports are capped at 1.5kW. One hybrid inverter is always the better option.
Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling
- CSIP-AUS compliant
- Inverter must be CSIP-AUS compliant under the current WA framework.
- VPP activation ready
- Needs to pair with an inverter listed for battery storage on Synergy's list.
- WA Battery Scheme rebate
- Requires Battery Rewards participation under the current WA framework.
- Synergy Battery Rewards
- Requires a CSIP-AUS compliant system and reliable internet.
- Interest-free loan
- Not eligible for interest-free financing.
Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings
Fault & error codes — Solinteg Integ E
Extracted from the installation manual
Showing 29 of 29. The official install manual is the authoritative source — always confirm before acting.
- Manual (PDF)
AC Transducer FaultcriticalCall your installerAC transducer failure
- Likely cause
- Internal malfunction
- What to do
- Restart the inverter.
- Manual (PDF)
Backup OPcriticalCall your installerOutput power over limitation on backup side
- Likely cause
- Excessive load on backup side
- What to do
- Check if the power load on backup side exceeds inverter capability.
- Manual (PDF)
Backup OVcriticalCall your installerAbnormal voltage on backup side
- Likely cause
- Overvoltage detected
- What to do
- Turn off inverter and check voltage on the backup connector.
- Manual (PDF)
Bus Voltage FaultcriticalCall your installerVoltage of bus circuit too high
- Likely cause
- Input voltage exceeds limit
- What to do
- Check input voltage and restart the inverter if needed.
- Manual (PDF)
E2 FaultcriticalCall your installerInternal storage abnormal
- Likely cause
- External magnetic field interference
- What to do
- Restart the inverter.
- Manual (PDF)
GFCI Device FaultcriticalCall your installerGFCI device malfunction
- Likely cause
- Internal failure of GFCI device
- What to do
- Restart the inverter and check GFCI.
- Manual (PDF)
GFCI FaultcriticalCall your installerExcess ground leakage current
- Likely cause
- PV panels or components may be damaged
- What to do
- Restart the inverter and inspect components for water damage.
- Manual (PDF)
Hard FaultcriticalCall your installerHardware protection triggered
- Likely cause
- Internal hardware failure
- What to do
- Restart the inverter and contact support if it persists.
- Manual (PDF)
Internal Fan FaultcriticalCall your installerInternal fan has failed
- Likely cause
- Obstruction or internal failure
- What to do
- Restart the inverter and clean the fan if necessary.
- Manual (PDF)
Inverter OCcriticalCall your installerLoad overload in off-grid mode
- Likely cause
- Impact load or short-circuit condition
- What to do
- Reduce load to prevent overload.
- Manual (PDF)
Inverter OFcriticalCall your installerFrequency over limit in off-grid mode
- Likely cause
- Impact load or short-circuit condition
- What to do
- Inspect load conditions and correct as necessary.
- Manual (PDF)
Inverter OVcriticalCall your installerPower exceeds inverter limits in off-grid mode
- Likely cause
- Impact load or short circuit present
- What to do
- Check load conditions and correct any issues.
- Manual (PDF)
Inverter Over TemperaturecriticalCall your installerInverter high internal temperature
- Likely cause
- Poor ventilation
- What to do
- Ensure good ventilation around the inverter and restart after cooling down.
- Manual (PDF)
ISO Over LimitationcriticalCall your installerLow insulation impedance to the ground
- Likely cause
- Components may be damaged or waterlogged
- What to do
- Inspect PV panels, cables, and connectors for damage. Use a megger to measure ground resistance.
- Manual (PDF)
PV Over VoltagecriticalCall your installerPV input voltage exceeds limits
- Likely cause
- Too many PV panels connected
- What to do
- Reduce the number of PV panels connected to meet voltage requirements.
- Manual (PDF)
Relay Check FailcriticalCall your installerInternal relay self-check failure
- Likely cause
- Loose or poor connections on AC side
- What to do
- Check neutral & ground connection on AC side, restart the inverter if necessary.
- Manual (PDF)
Bat OVwarningBattery protection triggered
- Likely cause
- Battery operating outside of its limits
- What to do
- Check the working status of the battery.
- Manual (PDF)
BMS Comm FaultwarningCall your installerCommunication failure with battery BMS
- Likely cause
- Faulty BMS connection
- What to do
- Check BMS connection and battery status.
- Manual (PDF)
Bus Volt LowwarningLow bus voltage
- Likely cause
- Abnormal power scheduling
- What to do
- Check battery voltage and PV input voltage for abnormalities.
- Manual (PDF)
DCI FaultwarningCall your installerDirect current injection exceeds limits
- Likely cause
- Inverter detects high DC injection value
- What to do
- Restart the inverter.
- Manual (PDF)
External Fan FaultwarningExternal fan has failed
- Likely cause
- Blockage or failure
- What to do
- Check for blockages, clean the fan as needed.
- Manual (PDF)
FLASH FaultwarningCall your installerInternal storage anomaly
- Likely cause
- Interference from external sources
- What to do
- Restart the inverter and check connections.
- Manual (PDF)
Grid Frequency FaultwarningCall your installerGrid frequency fault
- Likely cause
- Grid frequency is outside set protection value
- What to do
- Check whether the AC cable is correct and well connected. Change to another country with a wider protection range if allowed.
- Manual (PDF)
Grid Voltage FaultwarningCall your installerGrid voltage exceeds limits
- Likely cause
- AC cable wiring is incorrect or excessive impedance
- What to do
- Check whether the safety code is correct. Check whether the AC cable wiring is correct. Replace AC cable if needed.
- Manual (PDF)
Mains LostwarningGrid power outage
- Likely cause
- AC switch or circuit is disconnected
- What to do
- Check whether the mains supply is lost. Check whether the AC breaker and terminal are well connected.
- Manual (PDF)
Meter Comm FaultwarningCommunication between meter and inverter abnormal
- Likely cause
- Faulty communication connection
- What to do
- Check communication connection between meter and inverter.
- Manual (PDF)
N-PE Check FaultwarningGround cable loose or poorly connected
- Likely cause
- Bad wiring or connections
- What to do
- Check and correct ground cable wiring.
- Manual (PDF)
SCI FaultwarningCall your installerInternal communication failure
- Likely cause
- Interference from external sources
- What to do
- Restart the inverter.
- Manual (PDF)
SPI FaultwarningCall your installerInternal communication failure
- Likely cause
- External magnetic field interference
- What to do
- Restart the inverter.
About Solinteg
- Years on the CEC list
- 1+ (CEC-approved products since 2025)
- Local support
- Not verified
- CEC-listed products
- 8 models
Documents
Which size band is your home?
Usable capacity, for one battery system
- Smaller home
- 10 to 15 kWh
- Medium home
- 20 to 30 kWh
- Big home
- 30 to 40 kWh
- Very big home
- 40+ kWh
This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.
Does waiting change the rebate?
Estimated federal rebate (STCs) for this 101.25 kWh battery
Full datasheet
Every figure on file for the Solinteg Integ E, by section.
Lifespan & degradation
- Warranted throughput
- 30 MWh
Installation requirements
- Top clearance
- 500 mm
- Side clearance
- 300 mm
- Front clearance
- 500 mm
- AC breaker
- 15 A
- Cable gauge
- 10 mm²
- Earthing method
- TN-S
- DNSP pre-approval
- Yes
- Estimated install time
- 5 hrs
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
How it compares
The Solinteg E2BR-S112K-C-Neo against the closest-sized batteries from other brands.
| Specification | Solinteg E2BR-S112K-C-NeoSolinteg | GoodWe GW100KWH-D-10GoodWe | Solis Storage EverCore-100kWhSolis Storage |
|---|---|---|---|
| Usable capacity? | 101.25 kWhhighest | 100.8 kWh | 100.48 kWh |
| Continuous power (battery rating)? | Not on file | Not on file | Not on file |
| Peak power (battery rating)? | Not on file | Not on file | Not on file |
| Round-trip efficiency? | Not on file | Not on file | Not on file |
| Warranty | 10 years | Not on file | Not on file |
| Chemistry | LFP | LFP | LFP |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
More from Solinteg
Other CEC-approved products from Solinteg available in Australia.
Want to take the next step?
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.
Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.
Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.