Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. SAJ
  4. CHS2-29.9K-T4-204.8V/280Ah/51.5kWh

Home battery · SAJ · CEC approved April 2025

SAJ CHS2-29.9K-T4-204.8V/280Ah/51.5kWh

CEC listing: CHS2-29.9K-T4-204.8V/280Ah/51.5kWh (AS4777-2 2020)

A 51.5 kWh home battery. Very big home size, the 40+ kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
51.5kWh
Warranty
10yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

CHS2-29.9K-T4-204.8V/280Ah/51.5kWh: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

What we can tell you

Read from the figures on this page. No review written yet.

  • 51.5 kWh sits in the very big home band (40+ kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
51.5kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the energy you store comes back out
Warranty
10yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Warranty and support

This warranty covers the CHS2 battery system for 10 years, ensuring 70% usable energy retention. Report defects within 30 days to make a claim.

Product
10 years; not transferable; full replacement
Throughput
Not on record
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 8 years on the CEC list. Confirm the claim process with your installer.
Perth heat
Rated to 50°C, which covers Perth's hottest days.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the SAJ CHS2, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Nominal capacity
57.3 kWh
Usable capacity
51.5 kWh

Lifespan & degradation

Warranted throughput
0 MWh

Physical

IP rating
IP55

Operating environment

Operating temperature
-30°C to 50°C

Installation requirements

Top clearance
100 mm
Side clearance
100 mm
Front clearance
100 mm
AC breaker
200 A
Cable gauge
50 mm²
Earthing method
TN-S
DNSP pre-approval
Yes
Estimated install time
5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

Fault & error codes — SAJ CHS2

Extracted from the installation manual

36 documented

Showing 36 of 36. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    Master Relay Error

    Likely cause
    Faulty relay or control circuit issue.
    What to do
    Contact installer for repair.
  • 16criticalCall your installer
    Manual (PDF)

    Off Grid Output Voltage Low

    Likely cause
    Low voltage detected at off-grid output.
    What to do
    Check connections; contact installer for inspection.
  • 17criticalCall your installer
    Manual (PDF)

    Off Grid Output Short Circuit

    Likely cause
    Short circuit at off-grid output.
    What to do
    Disconnect and check wiring immediately; contact installer.
  • 2criticalCall your installer
    Manual (PDF)

    Master EEPROM Error

    Likely cause
    Corrupted EEPROM data.
    What to do
    Contact installer for replacement.
  • 24criticalCall your installer
    Manual (PDF)

    Master No Grid Error

    Likely cause
    Loss of grid connection.
    What to do
    Check grid connection; contact installer if issue persists.
  • 25criticalCall your installer
    Manual (PDF)

    DC Reverse Connect Error

    Likely cause
    Reverse DC connection detected.
    What to do
    Disconnect and inspect connections; contact installer.
  • 27criticalCall your installer
    Manual (PDF)

    GFCI Error

    Likely cause
    Issue with Ground Fault Circuit Interrupter.
    What to do
    Inspect GFCI; contact installer if issues continue.
  • 31criticalCall your installer
    Manual (PDF)

    ISO Error

    Likely cause
    Isolation issue detected.
    What to do
    Inspect isolated grounding; contact installer.
  • 35criticalCall your installer
    Manual (PDF)

    Master Grid Phase Lost

    Likely cause
    Phase loss detected in grid.
    What to do
    Contact installer for repair.
  • 6criticalCall your installer
    Manual (PDF)

    GFCI Device Error

    Likely cause
    Fault in Ground Fault Circuit Interrupter.
    What to do
    Inspect GFCI; contact installer if issues continue.
  • 10warningCall your installer
    Manual (PDF)

    Master Phase1 Voltage Low

    Likely cause
    Undervoltage condition on phase 1.
    What to do
    Check phase voltage; contact installer if persists.
  • 11warningCall your installer
    Manual (PDF)

    Master Phase2 Voltage High

    Likely cause
    Overvoltage condition on phase 2.
    What to do
    Check phase voltage; contact installer if persists.
  • 12warningCall your installer
    Manual (PDF)

    Master Phase2 Voltage Low

    Likely cause
    Undervoltage condition on phase 2.
    What to do
    Check phase voltage; contact installer if persists.
  • 13warningCall your installer
    Manual (PDF)

    Master Phase3 Voltage High

    Likely cause
    Overvoltage condition on phase 3.
    What to do
    Check phase voltage; contact installer if persists.
  • 14warningCall your installer
    Manual (PDF)

    Master Phase3 Voltage Low

    Likely cause
    Undervoltage condition on phase 3.
    What to do
    Check phase voltage; contact installer if persists.
  • 15warning
    Manual (PDF)

    Grid Voltage 10Min High

    Likely cause
    Persistent high grid voltage.
    What to do
    Monitor grid voltage; contact installer if necessary.
  • 18warning
    Manual (PDF)

    Master Grid Frequency High

    Likely cause
    Grid frequency higher than normal range.
    What to do
    Monitor grid frequency; contact installer for persistent issues.
  • 19warning
    Manual (PDF)

    Master Grid Frequency Low

    Likely cause
    Grid frequency below normal range.
    What to do
    Monitor grid frequency; contact installer.
  • 20warning
    Manual (PDF)

    BAT Input Mode Error

    Likely cause
    Battery input mode misconfigured or error in connection.
    What to do
    Check battery configuration; contact installer if persists.
  • 21warningCall your installer
    Manual (PDF)

    Phase1 DCV High

    Likely cause
    High voltage on Phase 1 DC input.
    What to do
    Check DC input; contact installer if persists.
  • 22warningCall your installer
    Manual (PDF)

    Phase2 DCV High

    Likely cause
    High voltage on Phase 2 DC input.
    What to do
    Check DC input; contact installer if persists.
  • 23warningCall your installer
    Manual (PDF)

    Phase3 DCV High

    Likely cause
    High voltage on Phase 3 DC input.
    What to do
    Check DC input; contact installer if persists.
  • 26warningCall your installer
    Manual (PDF)

    Parallel machine CAN Com Error

    Likely cause
    Communication error in parallel systems.
    What to do
    Inspect connections; contact installer if persists.
  • 28warningCall your installer
    Manual (PDF)

    Phase1 DCI Error

    Likely cause
    Current input issue on Phase 1.
    What to do
    Check phase connections; contact installer if necessary.
  • 29warningCall your installer
    Manual (PDF)

    Phase2 DCI Error

    Likely cause
    Current input issue on Phase 2.
    What to do
    Check phase connections; contact installer if necessary.
  • 3warningCall your installer
    Manual (PDF)

    Master Temperature High Error

    Likely cause
    Overheating of the unit.
    What to do
    Check ventilation and cooling; contact installer if persists.
  • 30warningCall your installer
    Manual (PDF)

    Phase3 DCI Error

    Likely cause
    Current input issue on Phase 3.
    What to do
    Check phase connections; contact installer if necessary.
  • 32warningCall your installer
    Manual (PDF)

    Bus Voltage Balance Error

    Likely cause
    Internal bus voltage imbalance detected.
    What to do
    Contact installer for inspection.
  • 33warningCall your installer
    Manual (PDF)

    Master Bus Voltage High

    Likely cause
    Bus voltage exceeding limits.
    What to do
    Contact installer for inspection.
  • 34warningCall your installer
    Manual (PDF)

    Master Bus Voltage Low

    Likely cause
    Bus voltage below limits.
    What to do
    Contact installer for inspection.
  • 36warningCall your installer
    Manual (PDF)

    Master PV Voltage High

    Likely cause
    PV voltage exceeds safe limits.
    What to do
    Check PV connection; contact installer if persists.
  • 4warning
    Manual (PDF)

    Master Temperature Low Error

    Likely cause
    Under temperature due to environmental factors.
    What to do
    Ensure unit is within operating temperature; contact installer if persists.
  • 5warning
    Manual (PDF)

    Lost Communication MS

    Likely cause
    Communication failure between master and slave.
    What to do
    Restart system; contact installer if persists.
  • 7warningCall your installer
    Manual (PDF)

    DCI Device Error

    Likely cause
    Issue with DC input circuit.
    What to do
    Contact installer for inspection and repair.
  • 8warningCall your installer
    Manual (PDF)

    Current Sensor Error

    Likely cause
    Faulty current sensor or wiring issues.
    What to do
    Contact installer for inspection.
  • 9warningCall your installer
    Manual (PDF)

    Master Phase1 Voltage High

    Likely cause
    Overvoltage condition on phase 1.
    What to do
    Check phase voltage; contact installer if persists.

About SAJ

Years on the CEC list
8+ (CEC-approved products since 2018)
Local support
Available
CEC-listed products
34 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$6,943

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 51.5 kWh battery

How it compares

The SAJ CHS2-29.9K-T4-204.8V/280Ah/51.5kWh against the closest-sized batteries from other brands.

Specification
SAJ CHS2-29.9K-T4-204.8V/280Ah/51.5kWhSAJ
ESYsunhome ESYSUNHOME10KWH+H-50ESYsunhome
Redback Technologies RED-P2-BE54HVRedback Technologies
Usable capacity?51.5 kWh✓highest51.43 kWh51.3 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?Not verifiedNot verifiedNot verified
Warranty10 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from SAJ

Other CEC-approved products from SAJ available in Australia.

SAJ Inverters

C6-100K-T9-40

100 kW · 3φ

C6-110K-T12-40

110 kW · 3φ

C6-125K-T12-40

125 kW · 3φ

C6-75K-T6-40

75 kW · 3φ

C6-99K-T9-40

99.999 kW · 3φ

CHS2-29.9K-T4-204.8V/280Ah/51.5kWh

29.999 kW · 3φ

View all SAJ inverters
View full SAJ manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?