Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. KSTAR
  4. BC160DE2A

Home battery · KSTAR · CEC approved August 2026

KSTAR BC160DE2A

A 157.54 kWh home battery. Very big home size, the 40+ kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
157.54kWh
Warranty
5yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

BC160DE2A: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Continuous powerRuns enough for a whole home, air conditioning included
50kWRuns enough for a whole home, air conditioning included

What we can tell you

Read from the figures on this page. No review written yet.

  • 157.54 kWh sits in the very big home band (40+ kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
157.54kWh
How much energy it stores for you to use
Continuous power
50kW
How much it can run at once: enough for a whole home, air conditioning included
Round-trip efficiency
98%
How much of the energy you store comes back out
Warranty
5yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type
Size and weight
75kg
2380 × 1100 × 1100 mm, roughly a large suitcase on the wall

Warranty and support

This warranty covers manufacturing defects for 5 years, excludes damages from misuse or environmental conditions, and claims can be made via our website.

Product
5 years; transferable; full replacement
Throughput
2.62 MWh
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 4 years on the CEC list. Confirm the claim process with your installer.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the KSTAR BluePulse, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Continuous power
50 kW
Round-trip efficiency
97.5%

Lifespan & degradation

Warranted throughput
2.62 MWh

Physical

Dimensions (H×W×D)
2380 × 1100 × 1100 mm
Weight
75 kg
IP rating
IP54

Installation requirements

Top clearance
1200 mm
Side clearance
1000 mm
Front clearance
1200 mm
AC breaker
32 A
Cable gauge
10 mm²
Earthing method
TN-S
DNSP pre-approval
No
Estimated install time
12 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

Fault & error codes — KSTAR BluePulse

Extracted from the installation manual

47 documented

Showing 47 of 47. The official install manual is the authoritative source — always confirm before acting.

  • F01criticalCall your installer
    Manual (PDF)

    INV Volt Short

    Likely cause
    Voltage short circuit detected in inverter.
    What to do
    Disconnect from power and check for faults.
  • F02criticalCall your installer
    Manual (PDF)

    GFCI Sensor Fault

    Likely cause
    Faulty GFCI sensor detected.
    What to do
    Inspect GFCI connections and replace if necessary.
  • F06criticalCall your installer
    Manual (PDF)

    Bus Short Circuit

    Likely cause
    Short circuit detected on bus connections.
    What to do
    Immediately disconnect power and inspect for shorts.
  • F07criticalCall your installer
    Manual (PDF)

    PV ISO Under Fault

    Likely cause
    Insulation fault detected in PV system.
    What to do
    Inspect PV connections and rectify insulation faults.
  • F08criticalCall your installer
    Manual (PDF)

    PV Input Short Circuit

    Likely cause
    Short circuit on PV input detected.
    What to do
    Disconnect and determine cause of short.
  • F10criticalCall your installer
    Manual (PDF)

    INV Curr Over

    Likely cause
    Inverter current exceeds rated limits.
    What to do
    Reduce load and inspect inverter for issues.
  • F11criticalCall your installer
    Manual (PDF)

    INV DC Over

    Likely cause
    DC voltage is exceeding inverter limits.
    What to do
    Check incoming DC connections and rectify.
  • F14criticalCall your installer
    Manual (PDF)

    Grid Relay Fault

    Likely cause
    Fault in the relay connecting to the grid.
    What to do
    Check for relay issues and replace if needed.
  • F15criticalCall your installer
    Manual (PDF)

    DisChg Curr Over

    Likely cause
    Discharge current is too high.
    What to do
    Reduce load and inspect battery connections.
  • F16criticalCall your installer
    Manual (PDF)

    Chg Curr Over

    Likely cause
    Charge current exceeds specifications.
    What to do
    Monitor charging setup and adjust if necessary.
  • F19criticalCall your installer
    Manual (PDF)

    EPS Relay Fault

    Likely cause
    Issue with Emergency Power Supply relay.
    What to do
    Inspect EPS relay and functionality.
  • F20criticalCall your installer
    Manual (PDF)

    Alway Over Load

    Likely cause
    Inverter has been overloaded continuously.
    What to do
    Audit loads to check compliance and reduce as needed.
  • W05criticalCall your installer
    Manual (PDF)

    Bat Loss

    Likely cause
    Battery is not connected or is faulty.
    What to do
    Check battery connections and functionality.
  • W09criticalCall your installer
    Manual (PDF)

    Over Load

    Likely cause
    Inverter is overloaded beyond capacity limits.
    What to do
    Reduce load and restart the inverter after a short wait.
  • W10criticalCall your installer
    Manual (PDF)

    GFCI Over

    Likely cause
    Ground Fault Circuit Interrupter has detected an overcurrent.
    What to do
    Check for potential wiring issues and restore connections.
  • W11criticalCall your installer
    Manual (PDF)

    LN Reverse

    Likely cause
    Line and Neutral are reversed in installation.
    What to do
    Turn off the inverter and check installation.
  • W17criticalCall your installer
    Manual (PDF)

    BMS Over Temp

    Likely cause
    Battery Management System detected overheating.
    What to do
    Allow cooling and check for ventilation issues.
  • W21criticalCall your installer
    Manual (PDF)

    BMS Under Volt

    Likely cause
    Battery voltage is critically low for operation.
    What to do
    Recharge battery immediately to prevent damage.
  • W23criticalCall your installer
    Manual (PDF)

    BMS Severe Over Volt

    Likely cause
    Voltage far exceeds safe limits within the battery.
    What to do
    Disconnect immediately and assess battery health.
  • W24criticalCall your installer
    Manual (PDF)

    BMS Severe Over Temp

    Likely cause
    Battery has reached a dangerously high temperature.
    What to do
    Cut power and allow to cool down before inspecting.
  • F00warning
    Manual (PDF)

    Soft Time Out

    Likely cause
    Device requires a reset after timeout.
    What to do
    Restart the inverter after appropriate checks.
  • F04warningCall your installer
    Manual (PDF)

    Bus Volt Low

    Likely cause
    Bus voltage is below normal operating range.
    What to do
    Check input voltage and restart if necessary.
  • F05warningCall your installer
    Manual (PDF)

    Bus Volt High

    Likely cause
    Bus voltage exceeds normal operating range.
    What to do
    Check supplies and allow system to stabilize.
  • F09warningCall your installer
    Manual (PDF)

    Bypass Relay Fault

    Likely cause
    Issue with bypass relay operation.
    What to do
    Check bypass relay functionality.
  • F12warningCall your installer
    Manual (PDF)

    Ambient Over Temp

    Likely cause
    Ambient temperature exceeds operational limits.
    What to do
    Ensure ventilation and cooling are adequate.
  • F13warningCall your installer
    Manual (PDF)

    Sink Over Temp

    Likely cause
    Temperature at sink exceeds limits.
    What to do
    Allow cooling, inspect ventilation.
  • F17warningCall your installer
    Manual (PDF)

    Current Sensor Fault

    Likely cause
    Fault in current sensing functionality.
    What to do
    Inspect current sensing connections and rectify.
  • F18warningCall your installer
    Manual (PDF)

    INV Abnormal

    Likely cause
    Inverter operation outside normal ranges.
    What to do
    Monitor inverter and report issues to installer.
  • F32warningCall your installer
    Manual (PDF)

    SCI Fault

    Likely cause
    Fault in System Control Interface.
    What to do
    Check interface connections and reset system.
  • W00warningCall your installer
    Manual (PDF)

    Grid Volt Low

    Likely cause
    Grid voltage is below acceptable limits.
    What to do
    Check grid connection and ensure voltage is within the acceptable range.
  • W01warningCall your installer
    Manual (PDF)

    Grid Volt High

    Likely cause
    Grid voltage is above acceptable limits.
    What to do
    Check grid connection and ensure voltage is within the acceptable range.
  • W02warningCall your installer
    Manual (PDF)

    Grid Frequency Low

    Likely cause
    Grid frequency is below acceptable limits.
    What to do
    Monitor grid frequency and check with local power company if issues persist.
  • W03warningCall your installer
    Manual (PDF)

    Grid Frequency High

    Likely cause
    Grid frequency is above acceptable limits.
    What to do
    Monitor grid frequency and check with local power company if issues persist.
  • W04warningCall your installer
    Manual (PDF)

    Solar Loss

    Likely cause
    The solar array is not producing enough power.
    What to do
    Check solar array connections and ensure solar panels are operational.
  • W06warningCall your installer
    Manual (PDF)

    Bat Under Volt

    Likely cause
    Battery voltage is below acceptable limits.
    What to do
    Charge the battery and ensure connections are secure.
  • W07warningCall your installer
    Manual (PDF)

    Bat Volt Low

    Likely cause
    Battery voltage is low.
    What to do
    Check battery health and connections, recharge if needed.
  • W08warningCall your installer
    Manual (PDF)

    Bat Volt High

    Likely cause
    Battery voltage is above acceptable limits.
    What to do
    Check battery health and if above settings, contact installer.
  • W12warningCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    Cooling fan is not functioning properly.
    What to do
    Inspect the fan and ensure it is operational.
  • W13warningCall your installer
    Manual (PDF)

    BAT Power Down

    Likely cause
    Battery is powered down or disconnected.
    What to do
    Check battery connections and ensure they are secure.
  • W14warningCall your installer
    Manual (PDF)

    BMS Discharge Over Current

    Likely cause
    Battery Management System detected over current during discharge.
    What to do
    Reduce load or disconnect temporarily to allow BMS to reset.
  • W15warningCall your installer
    Manual (PDF)

    BMS Charge Over Current

    Likely cause
    Battery Management System detected over current during charging.
    What to do
    Check the charging setup and reduce input current as needed.
  • W16warningCall your installer
    Manual (PDF)

    BMS Over Volt

    Likely cause
    Battery voltage exceeds safe operational limits set in BMS.
    What to do
    Disconnect and monitor the battery for abnormalities.
  • W18warningCall your installer
    Manual (PDF)

    BMS Discharge Low Temp

    Likely cause
    Temperature is too low for battery operation.
    What to do
    Move to a warmer environment if possible.
  • W19warningCall your installer
    Manual (PDF)

    Bms Volt Imbalance

    Likely cause
    Voltage across battery cells is not balanced.
    What to do
    Monitor battery performance and check for defects.
  • W20warningCall your installer
    Manual (PDF)

    Bms Communicate Fault

    Likely cause
    Communication error within Battery Management System.
    What to do
    Restart the system and check connections.
  • W22warningCall your installer
    Manual (PDF)

    Bms Chg Temp Low

    Likely cause
    Battery temperature is too low for charging.
    What to do
    Warm the battery environment if possible.
  • W25warningCall your installer
    Manual (PDF)

    CT Reverse

    Likely cause
    Current Transformer connections are reversed.
    What to do
    Check and correct CT connections.

About KSTAR

Years on the CEC list
4+ (CEC-approved products since 2022)
Local support
Available
CEC-listed products
42 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$6,943

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 157.54 kWh battery

How it compares

The KSTAR BC160DE2A against the closest-sized batteries from other brands.

Specification
KSTAR BC160DE2AKSTAR
Deye BOS-B176 Pro-A3Deye
SAJ CHS2-50K-T6-307.2V/280Ah/154.6kWhSAJ
Usable capacity?157.54 kWh159.12 kWh✓highest154.6 kWh
Continuous power?50 kWNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?98%Not verifiedNot verified
Warranty5 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from KSTAR

Other CEC-approved products from KSTAR available in Australia.

KSTAR Inverters

BluE-S 3680D

3.68 kW

BluE-S 3680D-M1

3.68 kW

BluE-S 5000D

5 kW

BluE-S 5000D-M1

5 kW

E10KT-D22

10 kW · 3φ

E12KT-D22

12 kW · 3φ

View all KSTAR inverters
View full KSTAR manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?