Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. FoxESS
  4. Power Cube series
  5. PQ3-10.0-L-M_EQ5500-S_8S

Home battery · FoxESS · Power Cube series · CEC approved November 2026

FoxESS PQ3-10.0-L-M_EQ5500-S_8S

CEC listing: PQ3-10.0-L-M_EQ5500-S_8S (AS4777-2 2020)

A 43.68 kWh home battery. Very big home size, the 40+ kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
43.68kWh
Warranty
12yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

Also CEC-registered as 6 other configurations

FOXESS lists this exact 43.68kWh configuration separately per compatible inverter pairing on the CEC register. These are the same physical battery, grouped here by pairing rather than shown as separate products.

PQ1-10.0_EQ5500-S_8S

  • PQ1-10.0_EQ5500-S_8S (AS4777-2 2020)

PQ1-12.0_EQ5500-S_8S

  • PQ1-12.0_EQ5500-S_8S (AS4777-2 2020)

PQ1-5.0_EQ5500-S_8S

  • PQ1-5.0_EQ5500-S_8S (AS4777-2 2020)

PQ1-8.0_EQ5500-S_8S

  • PQ1-8.0_EQ5500-S_8S (AS4777-2 2020)

PQ3-15.0-M_EQ5500-S_8S

  • PQ3-15.0-M_EQ5500-S_8S (AS4777-2 2020)

PQ3-5.0-M_EQ5500-S_8S

  • PQ3-5.0-M_EQ5500-S_8S (AS4777-2 2020)

PQ3-10.0-L-M_EQ5500-S_8S: the short answer

In the Power Cube seriesOne of 8 sizes, from 10.92 to 49.14 kWh
43.68kWhOne of 8 sizes, from 10.92 to 49.14 kWh
WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

Other sizes in the Power Cube series

  • 10.92 kWh
  • 16.38 kWh
  • 21.84 kWh
  • 27.3 kWh
  • 32.76 kWh
  • 38.22 kWh
  • 43.68 kWh (this one)
  • 49.14 kWh
  • See the whole series →

What we can tell you

Read from the figures on this page. No review written yet.

  • 43.68 kWh sits in the very big home band (40+ kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
43.68kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the energy you store comes back out
Warranty
12yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Warranty and support

Fox ESS warrants the Power Cube series for 12 years, covering defects in materials and workmanship, with exclusions for non-accredited installation. Claims can be initiated by the installer.

Product
12 years; transferable; full replacement
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Australian officeFoxESS Australia; 7 years on the CEC list. Direct manufacturer warranty. Australian consumer law applies.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the FoxESS Power Cube, by section.

Cell & chemistry

Chemistry
LFP

Physical

IP rating
IP65

Installation requirements

AC breaker
80 A
Cable gauge
16 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manual and compliance certificatePDF, opens in a new tab

Fault & error codes — FoxESS Power Cube

Extracted from the installation manual

44 documented

Showing 44 of 44. The official install manual is the authoritative source — always confirm before acting.

  • 10min Volt FaultcriticalCall your installer
    Manual (PDF)

    Grid voltage has been out of range for the last 10 minutes. The system will attempt to reconnect.

    Likely cause
    Persistent grid voltage issues.
    What to do
    Monitor the situation and seek assistance if the grid does not stabilize soon.
  • AFEFcriticalCall your installer
    Manual (PDF)

    AFE failed (UV/OV/UT/OT)

    Likely cause
    AFE has detected multiple failures (Under Vol, Over Vol, Under Temp, Over Temp)
    What to do
    Take immediate action to resolve issues per alerts given.
  • DCI FaultcriticalCall your installer
    Manual (PDF)

    DC component is out of limit in output current.

    Likely cause
    Incorrect DC connections or excess current flowing.
    What to do
    Disconnect PV, grid, and battery, then reconnect to see if the problem persists.
  • Grid Freq FaultcriticalCall your installer
    Manual (PDF)

    Grid frequency is out of range. Reconnection attempts will be made if the utility returns to normal.

    Likely cause
    Fluctuations in grid frequency.
    What to do
    Wait for the utility to stabilize the frequency, and contact support if the issue persists.
  • Grid Lost FaultcriticalCall your installer
    Manual (PDF)

    Grid connection lost. The system will try to reconnect if the grid is back to normal. If it does not return to normal, seek help.

    Likely cause
    No utility power supply or connection issue.
    What to do
    Wait for grid restoration or contact support if the issue persists.
  • Grid Volt FaultcriticalCall your installer
    Manual (PDF)

    Grid voltage is out of range. The system attempts to reconnect if the utility is back to normal.

    Likely cause
    Grid voltage fluctuations that exceed acceptable limits.
    What to do
    Monitor the grid voltage and seek assistance if the issue persists.
  • Ground FaultcriticalCall your installer
    Manual (PDF)

    Ground connection failure detected.

    Likely cause
    Improper grounding or wiring issues.
    What to do
    Check ground connections immediately; disconnect power and consult a professional.
  • HFBFcriticalCall your installer
    Manual (PDF)

    HVB FUSE fault

    Likely cause
    High voltage fuse has blown.
    What to do
    Replace fuse and check for shorts before powering up.
  • HW Inv Cur FaultcriticalCall your installer
    Manual (PDF)

    Output current high detected by hardware.

    Likely cause
    Electrical fault or damage affecting current sensing.
    What to do
    Disconnect all power sources; contact support for service.
  • Iso FaultcriticalCall your installer
    Manual (PDF)

    The isolation failed.

    Likely cause
    Damaged insulation in electrical wiring.
    What to do
    Stop using the inverter immediately; consult with a technician.
  • MFBFcriticalCall your installer
    Manual (PDF)

    Module FUSE fault

    Likely cause
    Fuse in one of the modules has blown.
    What to do
    Replace module fuse and investigate the cause.
  • OTFcriticalCall your installer
    Manual (PDF)

    Over temperature fault

    Likely cause
    Battery temperature exceeds safe operating conditions.
    What to do
    Allow the battery to cool down before resuming use.
  • Over Load Faultcritical
    Manual (PDF)

    Over load detected in on-grid mode.

    Likely cause
    Load demand exceeds inverter capacity.
    What to do
    Reduce load; wait and see if it stabilizes before restarting.
  • OVFcriticalCall your installer
    Manual (PDF)

    Over voltage fault

    Likely cause
    Battery voltage exceeds safe limits.
    What to do
    Disconnect the battery and check the inverter settings.
  • PFAcriticalCall your installer
    Manual (PDF)

    Power failed

    Likely cause
    System is not receiving power.
    What to do
    Ensure proper power connections and reset the system.
  • PLL_OverTimecriticalCall your installer
    Manual (PDF)

    The system detected that a three-phase system accessed single-phase AC. The system will try to reconnect.

    Likely cause
    Incorrect system configuration for three-phase connection.
    What to do
    Correct the connection and ensure a proper three-phase setup; contact support if needed.
  • SCFcriticalCall your installer
    Manual (PDF)

    Single Cell "0V" fault

    Likely cause
    A single battery cell has dropped to 0 volts.
    What to do
    Replace the affected cell immediately.
  • SCPcriticalCall your installer
    Manual (PDF)

    Short circuit Protection

    Likely cause
    Detected a short circuit in the system.
    What to do
    Disconnect power immediately and investigate cause.
  • SVHPFcriticalCall your installer
    Manual (PDF)

    The Single voltage high permanently failed

    Likely cause
    A single cell or module has high permanent voltage.
    What to do
    Inspect and replace the faulty unit if necessary.
  • SW Bus Vol FaultcriticalCall your installer
    Manual (PDF)

    Bus voltage out of range detected by software.

    Likely cause
    Possible wiring or component failure.
    What to do
    Ensure proper wiring; check connections and consult support if the issue continues.
  • SW Inv Cur FaultcriticalCall your installer
    Manual (PDF)

    Output current high detected by software. Firmware update required.

    Likely cause
    Excessive current output from inverter.
    What to do
    Update to the latest firmware and disconnect PV, grid, and battery, then reconnect.
  • THPFcriticalCall your installer
    Manual (PDF)

    Temperature high permanent failed

    Likely cause
    Permanent high temperature condition detected.
    What to do
    Allow the battery to cool down and check for malfunction.
  • UVFcriticalCall your installer
    Manual (PDF)

    Under voltage fault

    Likely cause
    Battery voltage falls below a critical level.
    What to do
    Charge the battery immediately to prevent damage.
  • ACFwarningCall your installer
    Manual (PDF)

    AFE communication failed

    Likely cause
    Communication issue with battery management system.
    What to do
    Check the connection and reset the system.
  • Bat Volt FaultwarningCall your installer
    Manual (PDF)

    Battery voltage fault detected.

    Likely cause
    Battery is over or under voltage.
    What to do
    Check battery connections; ensure proper charging conditions are met.
  • BCFwarningCall your installer
    Manual (PDF)

    BMU Communication failed

    Likely cause
    Failed communication with battery management unit.
    What to do
    Reconnect the communication lines.
  • COCwarningCall your installer
    Manual (PDF)

    Charge over current

    Likely cause
    Too much current is being fed into the battery during charging.
    What to do
    Check charger settings and reduce charging current.
  • COPwarningCall your installer
    Manual (PDF)

    Charge over power

    Likely cause
    Exceeding power input limit during charging.
    What to do
    Check charging setup and reduce power input.
  • DOCwarningCall your installer
    Manual (PDF)

    Discharge over current

    Likely cause
    Attempting to draw too much power from the battery.
    What to do
    Reduce load on the battery.
  • DOPwarningCall your installer
    Manual (PDF)

    Discharge over power

    Likely cause
    Exceeding battery's power output limit during discharge.
    What to do
    Reduce the power draw from the battery.
  • ICFwarningCall your installer
    Manual (PDF)

    IVU Communication failed

    Likely cause
    Failed communication with inverter.
    What to do
    Check communication cable between inverter and battery.
  • ISVFwarningCall your installer
    Manual (PDF)

    Internal total voltage sampling failed

    Likely cause
    Failed voltage measurement inside the system.
    What to do
    Contact technician to inspect and resolve.
  • MAFwarningCall your installer
    Manual (PDF)

    Module Addressing failed

    Likely cause
    Failed to address communication modules.
    What to do
    Reconfigure and check the connections of the modules.
  • OFwarningCall your installer
    Manual (PDF)

    Other fault

    Likely cause
    Indeterminate fault in the system.
    What to do
    Consult manual or technician for further diagnostics.
  • PCFwarningCall your installer
    Manual (PDF)

    PCS Communication failed

    Likely cause
    Failed communication with power conversion system.
    What to do
    Inspect wiring and settings for errors.
  • RAFwarningCall your installer
    Manual (PDF)

    Relay adhesion

    Likely cause
    Relay stuck in an open or closed position.
    What to do
    Inspect and test relays.
  • RDFwarningCall your installer
    Manual (PDF)

    Relay drive failed

    Likely cause
    Failure in the relay drive circuit.
    What to do
    Check relay drivers for faults.
  • RNCwarningCall your installer
    Manual (PDF)

    Relay Not Close

    Likely cause
    Relay failed to close properly during operation.
    What to do
    Inspect the relay system and connections.
  • SHFwarningCall your installer
    Manual (PDF)

    Shutdown failed

    Likely cause
    Unable to initiate shutdown procedure.
    What to do
    Inspect system for fault; consult technician if unsure.
  • SOHFPwarningCall your installer
    Manual (PDF)

    SOH low protection

    Likely cause
    State of Health of the battery is degraded.
    What to do
    Monitor battery health closely and plan for replacement.
  • SW Bat Cur FaultwarningCall your installer
    Manual (PDF)

    Battery current high detected by software.

    Likely cause
    Possible battery overload or fault.
    What to do
    Disconnect battery temporarily to reset; contact support if needed.
  • Temp Faultwarning
    Manual (PDF)

    The inverter temperature is high.

    Likely cause
    Poor ventilation or high ambient temperature.
    What to do
    Ensure adequate cooling and ventilation; check for obstruction around the inverter.
  • TSFwarningCall your installer
    Manual (PDF)

    Temperature sampling failed

    Likely cause
    Failed temperature measurement.
    What to do
    Check temperature sensors and connections.
  • UTFwarningCall your installer
    Manual (PDF)

    Under temperature fault

    Likely cause
    Battery temperature is too low for safe operation.
    What to do
    Warm up the battery to safe operating temperature.

About FoxESS

Years on the CEC list
7+ (CEC-approved products since 2019)
Local support
Available
CEC-listed products
172 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$6,703

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 43.68 kWh battery

How it compares

The FoxESS PQ3-10.0-L-M_EQ5500-S_8S against the closest-sized batteries from other brands.

Specification
FoxESS PQ3-10.0-L-M_EQ5500-S_8SFoxESS
Energizer ES5500-L8Energizer
Sigenergy SigenStor-10S-43.9Sigenergy
Usable capacity?43.68 kWh✓highest43.68 kWh✓highest43.6 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?Not verifiedNot verifiedNot verified
Warranty12 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from FoxESS

Other CEC-approved products from FoxESS available in Australia.

FoxESS Inverters

1K5-1P-HI-10.5

10.5 kW

1K5-1P-HI-10

10 kW

1K5-1P-HI-3.7

3.68 kW

1K5-1P-HI-4.6

4.6 kW

1K5-1P-HI-5

5 kW

1K5-1P-HI-6

6 kW

View all FoxESS inverters
View full FoxESS manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?