Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Deye
  4. BOS-GX series
  5. BOS-G25

Home battery · Deye · BOS-GX series · CEC approved December 2023

Deye BOS-G25

A 23.04 kWh home battery with backup power. Medium home size, the 20 to 30 kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
23.04kWh
Warranty
10yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

BOS-G25: the short answer

In the BOS-GX seriesOne of 7 sizes, from 15.36 to 46.08 kWh
23.04kWhOne of 7 sizes, from 15.36 to 46.08 kWh
WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Check eligibilityThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Continuous powerRuns enough for a whole home, air conditioning included
25.6kWRuns enough for a whole home, air conditioning included

Other sizes in the BOS-GX series

  • 15.36 kWh
  • 20.48 kWh
  • 25.6 kWh (this one)
  • 30.72 kWh
  • 35.84 kWh
  • 40.96 kWh
  • 46.08 kWh
  • See the whole series →

What we can tell you

Read from the figures on this page. No review written yet.

  • 23.04 kWh sits in the medium home band (20 to 30 kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
23.04kWh
How much energy it stores for you to use
Continuous power
25.6kW
How much it can run at once: enough for a whole home, air conditioning included
Round-trip efficiency
90%
How much of the energy you store comes back out
Depth of discharge
90%
How much of the battery you can actually use
Warranty
10yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Warranty and support

This warranty covers defects for 10 years. Exclusions include unauthorized modifications. To claim, contact support.

Product
10 years; not transferable; full replacement
Throughput
Not on record
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 6 years on the CEC list. Confirm the claim process with your installer.
Perth heat
Rated to 55°C, which covers Perth's hottest days.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Check eligibility

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Deye BOS-GX, by section.

Cell & chemistry

Chemistry
LFP
Cell type
LFP

Capacity & power

Nominal capacity
5.12 kWh
Usable capacity
23.04 kWh
Continuous power
25.6 kW
Peak power
125 kW
Depth of discharge
90%
Round-trip efficiency
90%
Nominal voltage
256 V

Lifespan & degradation

Cycle life
6000 cycles
Warranted throughput
0 MWh

Modularity & stacking

Modular / stackable
Yes
Maximum stack
5.12 kWh

Backup & grid services

Backup capable
Yes
VPP ready
No

Physical

Dimensions (H×W×D)
530 × 602 × 218 mm
Weight
15.5 kg
IP rating
IP20

Operating environment

Operating temperature
-20°C to 55°C

Installation requirements

Top clearance
100 mm
Side clearance
100 mm
Front clearance
100 mm
AC breaker
160 A
Cable gauge
10 mm²
Earthing method
TN-S
DNSP pre-approval
No
Estimated install time
8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

Fault & error codes — Deye BOS-GX

Extracted from the installation manual

65 documented

Showing 65 of 65. The official install manual is the authoritative source — always confirm before acting.

  • F001criticalCall your installer
    Manual (PDF)

    Excessive total pressure

    Likely cause
    System voltage exceeds safe limits
    What to do
    Check the system connections and parameters, then restart the system.
  • F003criticalCall your installer
    Manual (PDF)

    Charging temperature is too high

    Likely cause
    High ambient temperature or abnormal charging process
    What to do
    Stop charging immediately and allow cooling.
  • F004criticalCall your installer
    Manual (PDF)

    High discharge temperature

    Likely cause
    High ambient temperature or discharge overload
    What to do
    Stop discharging and let cool down.
  • F007criticalCall your installer
    Manual (PDF)

    Excessive differential pressure

    Likely cause
    Voltage differential exceeds limits between cells
    What to do
    Check cell voltage balance and connections.
  • F008criticalCall your installer
    Manual (PDF)

    Excessive temperature differentials

    Likely cause
    Significant temperature imbalance between cells
    What to do
    Check and balance cell temperatures immediately.
  • F009criticalCall your installer
    Manual (PDF)

    Cell overvoltage

    Likely cause
    Individual cell voltage exceeds safe limits
    What to do
    Disconnect and check cells for faults.
  • F011criticalCall your installer
    Manual (PDF)

    The temperature of the precharge resistance is too high

    Likely cause
    High load or faulty pre-charge components
    What to do
    Stop using, allow cooling and check components.
  • F012criticalCall your installer
    Manual (PDF)

    The temperature of the BMS connector is too high

    Likely cause
    Poor connection or overload on BMS
    What to do
    Disconnect and check connections immediately.
  • F013criticalCall your installer
    Manual (PDF)

    The BMU connector temperature is too high

    Likely cause
    Poor connection or overload on BMU
    What to do
    Disconnect and check connections immediately.
  • F014criticalCall your installer
    Manual (PDF)

    Charging current fault

    Likely cause
    Current exceeds safe charging limits
    What to do
    Stop charging and check system parameters.
  • F015criticalCall your installer
    Manual (PDF)

    Discharge current fault

    Likely cause
    Current exceeds safe discharge limits
    What to do
    Stop discharging and check system parameters.
  • F017criticalCall your installer
    Manual (PDF)

    Insulation fault

    Likely cause
    Insulation failure in the system
    What to do
    Disconnect immediately and check for leaks.
  • F018criticalCall your installer
    Manual (PDF)

    The heating film is too high

    Likely cause
    Overheating of heating elements
    What to do
    Stop operation and allow parts to cool.
  • F021criticalCall your installer
    Manual (PDF)

    Total positive relay bonding

    Likely cause
    Relay feedback indicates bonding issue
    What to do
    Check and repair bonding connections.
  • F022criticalCall your installer
    Manual (PDF)

    The charging relay is glued

    Likely cause
    Relay malfunction or dirt causing adhesion
    What to do
    Inspect and replace faulty relay.
  • F023criticalCall your installer
    Manual (PDF)

    The heating relay is glued

    Likely cause
    Relay malfunction or dirt causing adhesion
    What to do
    Inspect and replace faulty relay.
  • F024criticalCall your installer
    Manual (PDF)

    Ultimate protection

    Likely cause
    Triggers due to multiple fault conditions
    What to do
    Immediate inspection and shutdown required.
  • F026criticalCall your installer
    Manual (PDF)

    Blown fuse

    Likely cause
    Excessive current or overload
    What to do
    Replace the fuse immediately and check for issues.
  • F029criticalCall your installer
    Manual (PDF)

    The internal CAN communication fails

    Likely cause
    Loss of communication between battery units
    What to do
    Check wiring and connections for errors.
  • F030criticalCall your installer
    Manual (PDF)

    The PCS CAN communication fails

    Likely cause
    Loss of communication with Power Control System
    What to do
    Inspect connections and reset via the system.
  • F031criticalCall your installer
    Manual (PDF)

    The PCS RS485 communication fails

    Likely cause
    Communication fault detected with RS485
    What to do
    Check wiring and restart PCS communications.
  • F037criticalCall your installer
    Manual (PDF)

    Voltage collection fault

    Likely cause
    Failure in voltage sensing overall system
    What to do
    Inspect connections and replace faulty sensors.
  • F038criticalCall your installer
    Manual (PDF)

    Temperature acquisition fault

    Likely cause
    Failure in temperature sensing
    What to do
    Inspect and replace faulty temperature sensors.
  • F039criticalCall your installer
    Manual (PDF)

    Current acquisition fault

    Likely cause
    Failure in current readings or sensors
    What to do
    Inspect current sensors and replace faulty parts.
  • F040criticalCall your installer
    Manual (PDF)

    Current module fault

    Likely cause
    Malfunction in current measuring components
    What to do
    Inspect the current module and replace if necessary.
  • F041criticalCall your installer
    Manual (PDF)

    Total positive relay drive failure

    Likely cause
    Failure in relay operation due to numerous faults
    What to do
    Disconnect and check the relay functionality.
  • F042criticalCall your installer
    Manual (PDF)

    Charging relay drive failure

    Likely cause
    Faulty relay preventing charging
    What to do
    Replace faulty relay and check charging operations.
  • F043criticalCall your installer
    Manual (PDF)

    Discharge relay drive failure

    Likely cause
    Faulty relay preventing discharge
    What to do
    Replace faulty relay and check discharge operations.
  • F044criticalCall your installer
    Manual (PDF)

    Heating relay drive failure

    Likely cause
    Faulty relay preventing heating functions
    What to do
    Inspect and replace heating relay as necessary.
  • F045criticalCall your installer
    Manual (PDF)

    The EEPROM storage is faulty

    Likely cause
    Failure in EEPROM memory during operations
    What to do
    Inspect EEPROM and replace if necessary.
  • F046criticalCall your installer
    Manual (PDF)

    The precharge failed

    Likely cause
    Failed to complete precharge sequence
    What to do
    Inspect precharge circuit and reset operations.
  • F048criticalCall your installer
    Manual (PDF)

    The BMU communication is faulty

    Likely cause
    Communication failure between systems
    What to do
    Check communication paths and reset connections.
  • F050criticalCall your installer
    Manual (PDF)

    Temperature collection of the BMS connector is abnormal

    Likely cause
    Fault in temperature sensing at connectors
    What to do
    Inspected BMS connectors and rectify.
  • F051criticalCall your installer
    Manual (PDF)

    The temperature collection of the BMU connector is abnormal

    Likely cause
    Fault in temperature sensing at BMU
    What to do
    Inspect BMU connectors and ensure function.
  • F052criticalCall your installer
    Manual (PDF)

    PACK thermal runaway fault

    Likely cause
    Li-ion cells reaching destructive temperatures
    What to do
    Immediate cooling and disconnect required.
  • F053criticalCall your installer
    Manual (PDF)

    PACK fire failure

    Likely cause
    Fire detected in cell assembly
    What to do
    Use fire extinguisher and evacuate the area.
  • F055criticalCall your installer
    Manual (PDF)

    The W5500SPI communication fails

    Likely cause
    Fault detected in communication port
    What to do
    Inspect communication wiring and rectify.
  • F056criticalCall your installer
    Manual (PDF)

    LC communication loss

    Likely cause
    Loss of communication with local controller
    What to do
    Check connections to LC and troubleshoot issues.
  • F057criticalCall your installer
    Manual (PDF)

    BMU AFE communication fails

    Likely cause
    Fault in battery communication module
    What to do
    Inspect BMU components and connections.
  • F059criticalCall your installer
    Manual (PDF)

    The battery type does not match

    Likely cause
    Mismatch in installed battery types
    What to do
    Identify battery types installed and rectify within specifications.
  • ISOcriticalCall your installer
    Manual (PDF)

    Insulation failure

    Likely cause
    Risk of current leakage due to insulation issues.
    What to do
    Immediately shut down the system and check insulation.
  • F002warningCall your installer
    Manual (PDF)

    The total pressure is too low

    Likely cause
    System voltage falls below safe limits
    What to do
    Verify battery connections and charge status.
  • F005warningCall your installer
    Manual (PDF)

    The charging temperature is too low

    Likely cause
    Ambient temperature below optimal charging conditions
    What to do
    Move the system to a warmer location before charging.
  • F006warningCall your installer
    Manual (PDF)

    The discharge temperature is too low

    Likely cause
    Ambient temperature below optimal discharge conditions
    What to do
    Move to a warmer location before discharging.
  • F010warningCall your installer
    Manual (PDF)

    Cell undervoltage

    Likely cause
    Individual cell voltage falls below safe limits
    What to do
    Charge immediately and check for faults.
  • F016warningCall your installer
    Manual (PDF)

    High SOC fault

    Likely cause
    State of Charge exceeds safe limits
    What to do
    Disconnect load and monitor battery levels.
  • F019warningCall your installer
    Manual (PDF)

    The SOC is too low

    Likely cause
    Battery voltage not sufficient for operation
    What to do
    Charge the battery as soon as possible.
  • F020warningCall your installer
    Manual (PDF)

    Total voltage is too low

    Likely cause
    Voltage drop below minimum system requirements
    What to do
    Check power sources and recharge.
  • F025warningCall your installer
    Manual (PDF)

    Abnormal supply voltage

    Likely cause
    Voltage levels outside normal operating range
    What to do
    Monitor input voltage and reactivate.
  • F027warningCall your installer
    Manual (PDF)

    The BMU repeatedly fails

    Likely cause
    Persistence of faults in Battery Management Unit
    What to do
    Check configuration and reset BMU.
  • F028warningCall your installer
    Manual (PDF)

    The BMS is faulty repeatedly

    Likely cause
    BMS experiencing continuous faults
    What to do
    Disconnect and test BMS function.
  • F032warningCall your installer
    Manual (PDF)

    The PCS RS485 communication is abnormal

    Likely cause
    Abnormal data or continuity in RS485 line
    What to do
    Test the RS485 connections and wire conditions.
  • F033warningCall your installer
    Manual (PDF)

    The FUSE total pressure collection is abnormal

    Likely cause
    Fault in voltage sensing circuitry
    What to do
    Check FUSE circuits and connections.
  • F034warningCall your installer
    Manual (PDF)

    Abnormal internal total pressure collection

    Likely cause
    Discrepancy in internal cell voltage readings
    What to do
    Check internal connections and recalibrate if necessary.
  • F035warningCall your installer
    Manual (PDF)

    The Mot total pressure collection is abnormal

    Likely cause
    Fault in motor readings
    What to do
    Inspect motor components and test operation.
  • F036warningCall your installer
    Manual (PDF)

    The heating total pressure collection is abnormal

    Likely cause
    Heating elements not functioning correctly
    What to do
    Inspect heating system and check for faults.
  • F047warningCall your installer
    Manual (PDF)

    The charging voltage is too low

    Likely cause
    Supply voltage below safe thresholds
    What to do
    Check voltage input and connections.
  • F049warningCall your installer
    Manual (PDF)

    The number of BMUs is abnormal

    Likely cause
    Discrepancy in expected vs actual BMU count
    What to do
    Confirm BMU presence and reset systems if needed.
  • F054warningCall your installer
    Manual (PDF)

    TCP connection failure

    Likely cause
    Loss of TCP signal during operation
    What to do
    Check network settings and reset connections.
  • F058warningCall your installer
    Manual (PDF)

    Bluetooth initialization failed

    Likely cause
    Failed to initialize Bluetooth communication
    What to do
    Check Bluetooth setup and restart pairing process.
  • OCwarningCall your installer
    Manual (PDF)

    Charging overcurrent

    Likely cause
    Current exceeds safe charging parameters.
    What to do
    Reduce charging capacity and inspect current settings.
  • OTwarningCall your installer
    Manual (PDF)

    Overtemperature

    Likely cause
    The system's temperature exceeds safe limits.
    What to do
    Allow the system to cool down and inspect for overheating sources.
  • OVwarningCall your installer
    Manual (PDF)

    Overvoltage

    Likely cause
    The total charge voltage exceeds the threshold.
    What to do
    Inspect the system for voltage regulation issues.
  • UVwarningCall your installer
    Manual (PDF)

    Undervoltage

    Likely cause
    The battery voltage drops below the threshold.
    What to do
    Check battery conditions and charge if necessary.
  • OFinfo
    Manual (PDF)

    Other faults

    Likely cause
    Undetermined issues in the system operation.
    What to do
    Consult documentation or support for further troubleshooting.

About Deye

Years on the CEC list
6+ (CEC-approved products since 2020)
Local support
Available
CEC-listed products
53 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$5,267

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the medium home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 23.04 kWh battery

How it compares

The Deye BOS-G25 against the closest-sized batteries from other brands.

Specification
Deye BOS-G25Deye
Afore AF23000W-HUAfore
Cospowers CE-25-SCospowers
Usable capacity?23.04 kWh23.04 kWh23.04 kWh
Continuous power?25.6 kWNot verifiedNot verified
Peak power?125 kWNot verifiedNot verified
Round-trip efficiency?90%Not verifiedNot verified
Warranty10 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from Deye

Other CEC-approved products from Deye available in Australia.

Deye Inverters

AI-W5.1-10P1-AU-B

9.999 kW

AI-W5.1-10P3-AU-B

10 kW · 3φ

AI-W5.1-12P3-AU-B

12 kW · 3φ

AI-W5.1-3.6P1-AU-B

3.6 kW

AI-W5.1-5P1-AU-B

5 kW

AI-W5.1-5P3-AU-B

5 kW · 3φ

View all Deye inverters
View full Deye manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?