Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Deye
  4. BOS-B110

Home battery · Deye · CEC approved March 2026

Deye BOS-B110

A 102.96 kWh home battery. Very big home size, the 40+ kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
102.96kWh
Warranty
10yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

BOS-B110: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

What we can tell you

Read from the figures on this page. No review written yet.

  • 102.96 kWh sits in the very big home band (40+ kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
102.96kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
99%
How much of the energy you store comes back out
Depth of discharge
90%
How much of the battery you can actually use
Warranty
10yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Warranty and support

The battery is covered for 10 years against defects, ensuring at least 70% capacity retention. Warranty voids include improper installation and failure to operate within specified temperatures. Claims can be made by reporting to DEYE ESS with necessary details.

Product
10 years; not transferable; full replacement
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 6 years on the CEC list. Confirm the claim process with your installer.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Deye BOS-B, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Depth of discharge
90%
Round-trip efficiency
98.5%

Physical

IP rating
IP65

Installation requirements

Top clearance
5 mm
Side clearance
100 mm
Front clearance
100 mm
AC breaker
160 A
Cable gauge
4 mm²
Earthing method
TN-S
DNSP pre-approval
Yes
Estimated install time
12 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • Datasheet and compliance certificatePDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab

Fault & error codes — Deye BOS-B

Extracted from the installation manual

59 documented

Showing 59 of 59. The official install manual is the authoritative source — always confirm before acting.

  • F001criticalCall your installer
    Manual (PDF)

    Excessive total pressure

    Likely cause
    Total voltage exceeds maximum limit
    What to do
    Check battery voltage levels and disconnect if necessary
  • F009criticalCall your installer
    Manual (PDF)

    Cell overvoltage

    Likely cause
    Single cell voltage exceeds safe limit
    What to do
    Stop charging and check cells
  • F012criticalCall your installer
    Manual (PDF)

    The temperature of the BMS connector is too high

    Likely cause
    Overheating at the connector, indicating possible failure
    What to do
    Disconnect power and allow to cool
  • F013criticalCall your installer
    Manual (PDF)

    The BMU connector temperature is too high

    Likely cause
    Overheating at BMU connector due to high current
    What to do
    Disconnect the system and check connections
  • F014criticalCall your installer
    Manual (PDF)

    Charging current fault

    Likely cause
    Abnormal charging current detected
    What to do
    Stop charging and check connections
  • F015criticalCall your installer
    Manual (PDF)

    Discharge current fault

    Likely cause
    Abnormal discharge current detected
    What to do
    Stop discharging and check connections
  • F016criticalCall your installer
    Manual (PDF)

    High SOC fault

    Likely cause
    State of Charge exceeds safe limit
    What to do
    Stop charging immediately
  • F017criticalCall your installer
    Manual (PDF)

    Insulation fault

    Likely cause
    Insulation breakdown detected
    What to do
    Disconnect power and inspect insulation
  • F020critical
    Manual (PDF)

    The total voltage is too low

    Likely cause
    Total voltage of the system is below minimum
    What to do
    Recharge the battery system
  • F021criticalCall your installer
    Manual (PDF)

    Total positive relay bonding

    Likely cause
    Relay stuck in ON position
    What to do
    Check relay function and disconnect power
  • F022criticalCall your installer
    Manual (PDF)

    The charging relay is glued

    Likely cause
    Relay malfunction causing it to stick
    What to do
    Inspect and possibly replace relay
  • F023criticalCall your installer
    Manual (PDF)

    The heating relay is glued

    Likely cause
    Relay malfunction causing it to stick
    What to do
    Inspect and possibly replace heating relay
  • F024criticalCall your installer
    Manual (PDF)

    Ultimate protection triggered

    Likely cause
    Safety mechanism activated due to multiple failures
    What to do
    Disconnect system and seek professional assistance
  • F026criticalCall your installer
    Manual (PDF)

    Blown fuse

    Likely cause
    Fuse has blown due to overload
    What to do
    Replace blown fuse and check system
  • F027criticalCall your installer
    Manual (PDF)

    The BMU repeatedly fails

    Likely cause
    BMU has malfunctioned multiple times
    What to do
    Inspect the BMU for errors
  • F028criticalCall your installer
    Manual (PDF)

    The BMS is faulty repeatedly

    Likely cause
    BMS has malfunctioned multiple times
    What to do
    Inspect the BMS for errors
  • F029criticalCall your installer
    Manual (PDF)

    The internal CAN communication fails

    Likely cause
    CAN bus communication error within system
    What to do
    Check wiring and connections on CAN bus
  • F030criticalCall your installer
    Manual (PDF)

    The PCS CAN communication fails

    Likely cause
    No response from PCS on CAN bus
    What to do
    Check PCS and connections to system
  • F031criticalCall your installer
    Manual (PDF)

    The PCS RS485 communication fails

    Likely cause
    Loss of RS485 communication with PCS
    What to do
    Check RS485 connections and devices
  • F037criticalCall your installer
    Manual (PDF)

    Voltage collection fault

    Likely cause
    Sensor failure or connection issue
    What to do
    Check sensors and wiring
  • F038criticalCall your installer
    Manual (PDF)

    Temperature acquisition fault

    Likely cause
    Temperature sensor failure or issue
    What to do
    Inspect temperature sensors and wiring
  • F039criticalCall your installer
    Manual (PDF)

    Current acquisition fault

    Likely cause
    Current sensor failure or issue
    What to do
    Inspect current sensors and wiring
  • F040criticalCall your installer
    Manual (PDF)

    Current module fault

    Likely cause
    Hall current sensor reference failure
    What to do
    Inspect module for faults
  • F041criticalCall your installer
    Manual (PDF)

    Total positive relay drive failure

    Likely cause
    Relay mechanism is defective
    What to do
    Check and replace as needed
  • F042criticalCall your installer
    Manual (PDF)

    Charging relay drive failure

    Likely cause
    Relay mechanism is defective
    What to do
    Check and replace as needed
  • F043criticalCall your installer
    Manual (PDF)

    Discharge relay drive failure

    Likely cause
    Relay mechanism is defective
    What to do
    Check and replace as needed
  • F044criticalCall your installer
    Manual (PDF)

    Heating relay drive failure

    Likely cause
    Relay mechanism is defective
    What to do
    Check and replace as needed
  • F045criticalCall your installer
    Manual (PDF)

    The EEPROM storage is faulty

    Likely cause
    Error in EEPROM writes during self-test
    What to do
    Check EEPROM function
  • F046criticalCall your installer
    Manual (PDF)

    The precharge failed

    Likely cause
    Precharge circuit malfunction
    What to do
    Inspect precharge circuit and components
  • F048criticalCall your installer
    Manual (PDF)

    The BMU communication is faulty

    Likely cause
    Communication error with BMU
    What to do
    Inspect BMU communication wiring
  • F049criticalCall your installer
    Manual (PDF)

    The number of BMUs is abnormal

    Likely cause
    Mismatch in expected vs actual BMUs present
    What to do
    Verify system configuration and components
  • F052criticalCall your installer
    Manual (PDF)

    PACK thermal runaway fault

    Likely cause
    Thermal runaway condition detected in battery pack
    What to do
    Immediately disconnect power and cool down
  • F053criticalCall your installer
    Manual (PDF)

    PACK fire failure

    Likely cause
    Fire condition detected in battery pack
    What to do
    Disconnect power and use appropriate fire suppression
  • F056criticalCall your installer
    Manual (PDF)

    LC communication loss

    Likely cause
    Loss of connection to Logic Controller
    What to do
    Check LC connections
  • F057criticalCall your installer
    Manual (PDF)

    BMU AFE communication fails

    Likely cause
    Failure in communication to Active Front End
    What to do
    Inspect AFE connections
  • F002warning
    Manual (PDF)

    The total pressure is too low

    Likely cause
    Total voltage below minimum limit
    What to do
    Recharge the battery system
  • F003warningCall your installer
    Manual (PDF)

    Charging temperature is too high

    Likely cause
    Ambient temperature is above safe charging levels
    What to do
    Cool down the system before charging
  • F004warningCall your installer
    Manual (PDF)

    High discharge temperature

    Likely cause
    Excessive heat during discharge
    What to do
    Allow system to cool before use
  • F005warningCall your installer
    Manual (PDF)

    The charging temperature is too low

    Likely cause
    Temperature below safe limits for charging
    What to do
    Warm up the system before charging
  • F006warningCall your installer
    Manual (PDF)

    The discharge temperature is too low

    Likely cause
    Temperature below safe limits for discharging
    What to do
    Avoid discharging until warmed up
  • F007warningCall your installer
    Manual (PDF)

    Excessive differential pressure

    Likely cause
    Voltage difference between cells exceeds limits
    What to do
    Check individual cell voltages
  • F008warningCall your installer
    Manual (PDF)

    Excessive temperature differentials

    Likely cause
    Temperature difference between cells exceeds limits
    What to do
    Monitor temperature distribution
  • F010warning
    Manual (PDF)

    Cell undervoltage

    Likely cause
    Single cell voltage below safe limit
    What to do
    Recharge the battery system
  • F011warningCall your installer
    Manual (PDF)

    The temperature of the precharge resistance is too high

    Likely cause
    Overheating of precharge resistors
    What to do
    Allow to cool and inspect connections
  • F018warningCall your installer
    Manual (PDF)

    The heating film is too high

    Likely cause
    Overheating in heating film
    What to do
    Allow to cool and inspect heating elements
  • F019warning
    Manual (PDF)

    The SOC is too low

    Likely cause
    State of Charge is below acceptable limit
    What to do
    Recharge the battery system
  • F025warning
    Manual (PDF)

    Abnormal supply voltage

    Likely cause
    Voltage supplied to system is outside expected range
    What to do
    Check power supply and reconnect
  • F032warningCall your installer
    Manual (PDF)

    The PCS RS485 communication is abnormal

    Likely cause
    Abnormal signals detected on RS485
    What to do
    Inspect wiring for damage or malfunctions
  • F033warningCall your installer
    Manual (PDF)

    The FUSE total pressure collection is abnormal

    Likely cause
    Inaccurate reading from voltage collection
    What to do
    Check voltages and replace FUSE if necessary
  • F034warningCall your installer
    Manual (PDF)

    Abnormal internal total pressure collection

    Likely cause
    Internal measurements fail to correlate
    What to do
    Inspect internal components for faults
  • F035warningCall your installer
    Manual (PDF)

    The Mot total pressure collection is abnormal

    Likely cause
    Abnormal voltage readings detected
    What to do
    Check motor connections and functions
  • F036warningCall your installer
    Manual (PDF)

    The heating total pressure collection is abnormal

    Likely cause
    Inaccurate heating measurements
    What to do
    Inspect heating components for issues
  • F047warning
    Manual (PDF)

    The charging voltage is too low

    Likely cause
    Insufficient voltage supplied to charge
    What to do
    Check power supply to charging circuit
  • F050warningCall your installer
    Manual (PDF)

    Temperature collection of the BMS connector is abnormal

    Likely cause
    Sensor or connection errors
    What to do
    Check connections and component function
  • F051warningCall your installer
    Manual (PDF)

    The temperature collection of the BMU connector is abnormal

    Likely cause
    Sensor or connection errors
    What to do
    Check connections and component function
  • F054warning
    Manual (PDF)

    TCP connection failure

    Likely cause
    Network connection issue
    What to do
    Check network connections
  • F055warningCall your installer
    Manual (PDF)

    The W5500SPI communication fails

    Likely cause
    Breakdown in SPI communication
    What to do
    Inspect SPI connections
  • F058warning
    Manual (PDF)

    Bluetooth initialization failed

    Likely cause
    Error during Bluetooth setup
    What to do
    Restart system and attempt Bluetooth connection again
  • F059warning
    Manual (PDF)

    The battery type does not match

    Likely cause
    Mismatch between battery type and configuration
    What to do
    Verify battery type and settings

About Deye

Years on the CEC list
6+ (CEC-approved products since 2020)
Local support
Available
CEC-listed products
53 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$6,943

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 102.96 kWh battery

How it compares

The Deye BOS-B110 against the closest-sized batteries from other brands.

Specification
Deye BOS-B110Deye
Pylontech PowerCube-M1C-32/736V-L10Pylontech
Solinteg E2BR-S112K-CSolinteg
Usable capacity?102.96 kWh103.4816 kWh✓highest101.25 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?99%Not verifiedNot verified
Warranty10 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from Deye

Other CEC-approved products from Deye available in Australia.

Deye Inverters

AI-W5.1-10P1-AU-B

9.999 kW

AI-W5.1-10P3-AU-B

10 kW · 3φ

AI-W5.1-12P3-AU-B

12 kW · 3φ

AI-W5.1-3.6P1-AU-B

3.6 kW

AI-W5.1-5P1-AU-B

5 kW

AI-W5.1-5P3-AU-B

5 kW · 3φ

View all Deye inverters
View full Deye manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?