Hybrid inverter · Sungrow · CEC approved January 2025
CEC listing: SH6.0RS (AS4777-2 2020)
A 6 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
Every figure on file for the Sungrow SH6.0RS, by section.
| Specification | Value |
|---|---|
| Physical | |
| IP rating | IP65 |
| Operating temperature | -25°C to 60°C |
| Rebate eligibility | |
| Listed for battery storage on Synergy's list | Yes |
| Installation requirements | |
| Top clearance | 22 mm |
| Side clearance | 20 mm |
| AC breaker | 32 A |
| Cable gauge | 6 mm² |
| Earthing method | MEN |
| DNSP pre-approval | Yes |
| Estimated install time | 12 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list
Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
Australian office
Has local presence
Website
www.sungrowpower.com/au/enThe Sungrow SH6.0RS against the closest-power inverters from other brands.
| Specification | Sungrow SH6.0RSSungrow | Energizer FORCE 6.0HSEnergizer | Energizer Force 6.0HT+Energizer |
|---|---|---|---|
| Rated power? | 6 kW | 6 kW | 6 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers defects for 10 years. It doesn't cover misuse or incorrect installation. Claims can be made via the support page.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 20 of 20. The official install manual is the authoritative source — always confirm before acting.
002,003,014criticalCall your installerGrid overvoltage
004criticalCall your installerGrid undervoltage
028criticalCall your installerPV reverse connection fault
028,029criticalCall your installerPV reverse connection fault
039criticalCall your installerLow ISO resistance
9088criticalCall your installerArc fault
9716criticalCall your installerBattery polarity reversed
002warningCall your installerGrid overvoltage
003warningCall your installerGrid overvoltage
008warningCall your installerGrid overfrequency
009warningCall your installerGrid underfrequency
012warningCall your installerOverhigh leakage current
013warningCall your installerGrid abnormal
038,041,048,052,064-067,100,105,107,113,200-202,303,304,308,312,315,316,600,605,612,616,620warningCall your installerSystem fault
106warningCall your installerGrounding cable fault
9075warningCall your installerParallel communication alarm
932-935,937,939,964warningCall your installerBattery alarm
9714warningCall your installerBMS communication error
010infoGrid Power Outage
071,072,503-506,513,900,901infoCall your installerSystem alarm
SH6.0RS (AS4777-2 2020)
6 kW · 1φ
SG5.0RS-ADA (AS4777-2 2020)
4.999 kW · 1φ
SG5.0RS (AS4777-2 2020)
4.999 kW · 1φ
SG5K-D (AS4777-2 2020)
4.999 kW · 1φ
SG5K-D-NI (AS4777-2 2020)
4.999 kW · 1φ
SH5.0RS (AS4777-2 2020)
4.999 kW · 1φ
Other CEC-approved products from Sungrow available in Australia.
Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.