Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sungrow
  4. SH5.0RT

Hybrid inverter · Sungrow · CEC approved December 2024

Sungrow SH5.0RT

CEC listing: SH5.0RT (AS4777-2 2020)

A 5 kW three-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SH5.0RT: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
98.3%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Sungrow Power Supply Co Ltd stands behind it

Full datasheet

Every figure on file for the Sungrow SH5.0RT, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power5 kW
Efficiency
Max efficiency98.3%
European efficiency97.2%
Physical
Weight18 kg
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Cable gauge4 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
17 Dec 2024
Approval expiry
17 Dec 2027
Status
Active
Listed for STCs
Yes

About Sungrow

Years on the CEC list
5 years
Australian office
Yes
Category
Premium
CEC-approved inverters
50
CEC-approved batteries
19
CEC-approved panels
145
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Sungrow Power Supply Co Ltd batteries and panels→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Australian office

Has local presence

Website

www.sungrowpower.com/au/en
5 years on the CEC list

How it compares

The Sungrow SH5.0RT against the closest-power inverters from other brands.

Specification
Sungrow SH5.0RTSungrow
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?98.3%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Sungrow SH5.0RT

Sungrow offers a 10-year warranty on its inverters against defects in materials and workmanship. It does not cover issues caused by improper installation or use, and claims can be initiated by contacting the installer or Sungrow directly.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Failure to comply with operating instructions, faulty installation, unauthorized repairs, improper use, conditions exceeding specifications, damage during transportation, damage from other parts of the system, and force majeure events.
Read the official warranty document (PDF)

Fault & error codes — Sungrow SH5.0RT

From the install manual

17 documented

Showing 17 of 17. The official install manual is the authoritative source — always confirm before acting.

  • 009criticalCall your installer
    Manual (PDF)

    PV reverse connection fault

    Likely cause
    Incorrect wiring of PV strings.
    What to do
    Check polarity of PV strings and correct it.
  • 016criticalCall your installer
    Manual (PDF)

    Arc fault

    Likely cause
    Detects a potential arc condition in the DC circuit.
    What to do
    Disconnect DC inputs and inspect for damages.
  • 064criticalCall your installer
    Manual (PDF)

    System fault

    Likely cause
    Hardware or software error detected.
    What to do
    Disconnect AC and DC switches, then reconnect after 15 minutes.
  • 003warning
    Manual (PDF)

    Grid overfrequency

    Likely cause
    Grid frequency exceeds the specified thresholds.
    What to do
    Measure grid frequency and contact the local utility if it exceeds specifications.
  • 004warning
    Manual (PDF)

    Grid underfrequency

    Likely cause
    Grid frequency is below the specified thresholds.
    What to do
    Check AC cable connections and contact the local utility if the frequency is low.
  • 005warning
    Manual (PDF)

    No Grid

    Likely cause
    Inverter not connected to the grid.
    What to do
    Check AC cable connections and ensure the grid is supplying power.
  • 006warning
    Manual (PDF)

    Overhigh leakage current

    Likely cause
    Inverter detects excess leakage current.
    What to do
    Inspect AC and DC cables for insulation issues.
  • 007warning
    Manual (PDF)

    Grid abnormal

    Likely cause
    Unexpected fluctuations in the grid.
    What to do
    Measure grid frequency and contact the local utility if issues persist.
  • 008warning
    Manual (PDF)

    Grid voltage unbalance

    Likely cause
    Unequal voltages across different phases of the grid.
    What to do
    Measure grid phase voltage and contact utility if needed.
  • 01warning
    Manual (PDF)

    Grid overvoltage

    Likely cause
    Grid voltage exceeds the specified threshold.
    What to do
    Measure grid voltage and contact the local utility if it exceeds specifications.
  • 012warning
    Manual (PDF)

    High ambient temperature

    Likely cause
    Inverter exposed to high temperatures.
    What to do
    Take shading measures and ensure ventilation.
  • 013warning
    Manual (PDF)

    Low ambient temperature

    Likely cause
    Inverter operating outside of specified temperature range.
    What to do
    Disconnect inverter and wait until ambient temperature is acceptable before restarting.
  • 014warning
    Manual (PDF)

    Low ISO resistance

    Likely cause
    Insulation resistance lower than acceptable levels.
    What to do
    Inspect insulation resistance of the system and ensure compliance with local regulations.
  • 015warning
    Manual (PDF)

    Grounding cable fault

    Likely cause
    Issues with grounding cable connections.
    What to do
    Check grounding connections and insulation integrity.
  • 02warning
    Manual (PDF)

    Grid undervoltage

    Likely cause
    Grid voltage is below the specified threshold.
    What to do
    Measure grid voltage and contact the local utility if it is below specifications.
  • 063warning
    Manual (PDF)

    System alarm

    Likely cause
    General system issue detected.
    What to do
    Check cable connections and ambient environment.
  • 019info
    Manual (PDF)

    Smart Energy Meter communication error

    Likely cause
    Communication issues with the Smart Energy Meter.
    What to do
    Check communication cable and connections.

More Sungrow Power Supply Co Ltd inverters

SG5.0RT (AS4777-2 2020)

5 kW · 3φ

SH5T (AS4777-2 2020)

5 kW · 3φ

SG7.0RT (AS4777-2 2020)

6.999 kW · 3φ

SG8.0RT (AS4777-2 2020)

8 kW · 3φ

SG10RT (AS4777-2 2020)

9.999 kW · 3φ

SH10RT (AS4777-2 2020)

9.999 kW · 3φ

View all Sungrow Power Supply Co Ltd inverters

More from Sungrow

Other CEC-approved products from Sungrow available in Australia.

Sungrow Batteries

SBH100

10 kWh

SBH150

15 kWh

SBH200

20 kWh

SBH250

25 kWh

SBH300

30 kWh

SBH350

35 kWh

View all Sungrow batteries

Sungrow Solar Panels

SG-48TG2D-470

470W

SG-48TG2D-475

475W

SG-48TG2D-480

480W

SG-48TG2D-X-465

465W

SG-48TG2D-X-470

470W

SG-48TG2D-X-475

475W

View all Sungrow panels
View full Sungrow manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?