Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sungrow
  4. CX series
  5. SG110CX-NI

Solar inverter · Sungrow · CX series · CEC approval expired

Sungrow SG110CX-NI

CEC listing: SG110CX-NI (AS4777-2 2020)

A 110 kW single-phase solar inverter.

Rated power
110kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter

Commercial-scale inverter

At 110 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SG110CX-NI: the short answer

In the CX seriesThe 4th of 4 sizes, from 29.9 to 110 kW
110kWThe 4th of 4 sizes, from 29.9 to 110 kW
Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

Other sizes in the CX series

  • 29.9 kW
  • 50 kW
  • 100 kW
  • 110 kW (this one)

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
110kW
How much solar it can turn into usable power at once
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only

Full datasheet

Every figure on file for the Sungrow SG110CX-NI, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power110 kW
Efficiency
Max efficiency98.5%
European efficiency98.5%
Physical
Dimensions (H×W×D)795 × 1020 × 360 mm
Weight87 kg
IP ratingIP66
Installation requirements
Top clearance650 mm
Side clearance200 mm
AC breaker63 A
Cable gauge16 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
16 May 2023
Approval expiry
23 Aug 2025
Status
Not listed
Listed for STCs
No (not listed)

About Sungrow

Years on the CEC list
5 years
Australian office
Yes
Category
Premium
CEC-approved inverters
50
CEC-approved batteries
19
CEC-approved panels
145
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→
  • Sungrow batteries and panels→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Australian office

Has local presence

Website

www.sungrowpower.com/au/en
5 years on the CEC list

How it compares

The Sungrow SG110CX-NI against the closest-power inverters from other brands.

Specification
Sungrow SG110CX-NISungrow
Solplanet ASW110K-LTSolplanet
Solis S5-GC110K-AUSolis
Rated power?110 kW110 kW110 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseThree-phaseThree-phase
TypeSolarSolarSolar
Battery readyNoNoNo
WarrantyNot on fileNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab

Warranty summary

This warranty covers defects in materials and workmanship for 10 years. Exclusions include installation errors. Claims can be made through the support website or contact email.

10-year inverter warranty

Sungrow SG110CX-NI

This warranty covers defects in materials and workmanship for 10 years. Exclusions include installation errors. Claims can be made through the support website or contact email.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, unauthorized modifications, or tampering voids the warranty.
Environment limits
Not to be installed in coastal areas prone to salt damage
Read the official warranty document (PDF)

Fault & error codes — Sungrow SG110CX-NI

From the install manual

17 documented

Showing 17 of 17. The official install manual is the authoritative source — always confirm before acting.

  • 106criticalCall your installer
    Manual (PDF)

    Grounding Cable Fault

    Likely cause
    Improper grounding connection.
    What to do
    Check grounding connections and insulation.
  • 28criticalCall your installer
    Manual (PDF)

    PV Reserve Connection Fault

    Likely cause
    The corresponding string has reverse polarity.
    What to do
    Disconnect the DC switch and adjust the polarity when the string current drops below 0.5 A.
  • 29criticalCall your installer
    Manual (PDF)

    PV Reserve Connection Fault

    Likely cause
    The corresponding string has reverse polarity.
    What to do
    Disconnect the DC switch and adjust the polarity when the string current drops below 0.5 A.
  • 39criticalCall your installer
    Manual (PDF)

    Low System Insulation Resistance (Earth Fault)

    Likely cause
    Insulation is compromised.
    What to do
    Check insulation resistance and ensure compliance with local regulations.
  • 88criticalCall your installer
    Manual (PDF)

    Electric Arc Fault

    Likely cause
    Damaged cables or loose connections.
    What to do
    Inspect cables for damage and secure connections.
  • 10warning
    Manual (PDF)

    Grid Power Outage

    Likely cause
    Loss of grid power.
    What to do
    Check connection and wait for grid restoration.
  • 12warningCall your installer
    Manual (PDF)

    Excess Leakage Current

    Likely cause
    Poor environment or insulation issues.
    What to do
    Check insulation and improve environment if necessary.
  • 13warningCall your installer
    Manual (PDF)

    Grid Abnormal

    Likely cause
    Grid parameters exceed set range.
    What to do
    Measure actual grid parameters and contact power company if necessary.
  • 14warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage exceeded set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too high.
  • 15warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage exceeded set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too high.
  • 17warningCall your installer
    Manual (PDF)

    Grid Voltage Imbalance

    Likely cause
    The phase voltages differ significantly.
    What to do
    Measure the actual grid voltage. If voltages differ greatly, contact the electric power company.
  • 2warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage exceeded set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too high.
  • 3warningCall your installer
    Manual (PDF)

    Grid Overvoltage

    Likely cause
    Grid voltage exceeded set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too high.
  • 4warningCall your installer
    Manual (PDF)

    Grid Undervoltage

    Likely cause
    Grid voltage below set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too low.
  • 5warningCall your installer
    Manual (PDF)

    Grid Undervoltage

    Likely cause
    Grid voltage below set value.
    What to do
    Check actual grid voltage and contact local electric power company if value is too low.
  • 8warningCall your installer
    Manual (PDF)

    Grid Overfrequency

    Likely cause
    Grid frequency exceeded set range.
    What to do
    Check actual grid frequency and contact local electric power company if value is too high.
  • 9warningCall your installer
    Manual (PDF)

    Grid Underfrequency

    Likely cause
    Grid frequency below set range.
    What to do
    Check actual grid frequency and contact local electric power company if value is too low.

More Sungrow inverters

SC50HV-20 (AS4777-2 2020)

50 kW · 1φ

SG50CX (AS4777-2 2020)

50 kW · 1φ

SG50CX-NI (AS4777-2 2020)

50 kW · 1φ

SG30CX (AS4777-2 2020)

29.9 kW · 1φ

SG10RS (AS4777-2 2020)

9.999 kW · 1φ

SH10RS (AS4777-2 2020)

9.999 kW · 1φ

View all Sungrow inverters

More from Sungrow

Other CEC-approved products from Sungrow available in Australia.

Sungrow Batteries

SBH100

10 kWh

SBH150

15 kWh

SBH200

20 kWh

SBH250

25 kWh

SBH300

30 kWh

SBH350

35 kWh

View all Sungrow batteries

Sungrow Solar Panels

SG-48TG2D-470

470W

SG-48TG2D-475

475W

SG-48TG2D-480

480W

SG-48TG2D-X-465

465W

SG-48TG2D-X-470

470W

SG-48TG2D-X-475

475W

View all Sungrow panels
View full Sungrow manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?