Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SolaX Power
  4. X3-PRO-30K-G2

Solar inverter · SolaX Power · Not listed as CEC approved

SolaX Power X3-PRO-30K-G2

CEC listing: X3-PRO-30K-G2 (AS4777-2 2020)

A 30 kW single-phase solar inverter.

Rated power
30kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

X3-PRO-30K-G2: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • The register doesn't currently list it as CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
30kW
How much solar it can turn into usable power at once
Max efficiency
98.2%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
10yr
How long SolaX Power Network Technology (Zhe jiang) Co Ltd stands behind it

Full datasheet

Every figure on file for the SolaX Power X3-PRO-30K-G2, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power8 kW
Efficiency
Max efficiency98.2%
European efficiency97.7%
DC input & MPPT
MPPT trackers2
Physical
Dimensions (H×W×D)417 × 482 × 186 mm
Weight24.5 kg
IP ratingIP66
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker20 A
Cable gauge5 mm²
Earthing methodPE
DNSP pre-approvalNo
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
16 July 2025
Approval expiry
8 June 2027
Status
Not listed
Listed for STCs
No (not listed)

About SolaX Power

Years on the CEC list
5 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
137
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

5 years on the CEC list

How it compares

The SolaX Power X3-PRO-30K-G2 against the closest-power inverters from other brands.

Specification
SolaX Power X3-PRO-30K-G2SolaX Power
GoodWe GW29.999K-BTA-G20GoodWe
GoodWe GW29.999K-ETA-G20GoodWe
Rated power?29.999 kW29.999 kW29.999 kW
Max efficiency?98.2%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseThree-phaseThree-phase
TypeSolarBatteryHybrid
Battery readyNoYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guidePDF, opens in a new tab

10-year inverter warranty

SolaX Power X3-PRO-30K-G2

This warranty covers your inverter for 10 years with limited pro-rata support. Exclusions include improper installation. Claims can be made by contacting support via email.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voided by non-accredited installation, modifications, or tampering.
Environment limits
Coverage is void in extreme environments such as salt spray or excessive humidity.
Read the official warranty document (PDF)

Fault & error codes — SolaX Power X3-PRO-30K-G2

From the install manual

32 documented

Showing 32 of 32. The official install manual is the authoritative source — always confirm before acting.

  • AcTerminalOTPcriticalCall your installer
    Manual (PDF)

    AC Terminal Overtemperature Fault

    Likely cause
    The AC terminals are experiencing overheating.
    What to do
    Check if the AC terminals are tightly connected. Check if the ambient temperature exceeds the operating range. If the issue persists, seek help.
  • EepromFaultcriticalCall your installer
    Manual (PDF)

    DSP EEPROM Fault

    Likely cause
    Error with the EEPROM memory in the DSP.
    What to do
    Disconnect PV wiring and reconnect. If the issue persists, seek help.
  • FanFaultcriticalCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    The inverter's cooling fan has failed.
    What to do
    Check whether the fan is faulty or damaged. If the issue persists, seek help.
  • GridRelayFaultcriticalCall your installer
    Manual (PDF)

    Relay Fault

    Likely cause
    Error with the grid relay.
    What to do
    Check the grid connection. Restart the inverter. If the issue persists, seek help.
  • IsoFaultcriticalCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    Insulation failure detected.
    What to do
    Check the connections of the inverter. If the issue persists, seek help immediately.
  • Mgr EEPROM FaultcriticalCall your installer
    Manual (PDF)

    ARM EEPROM Fault

    Likely cause
    Error with the EEPROM memory in the ARM.
    What to do
    Disconnect PV and grid, then reconnect. If the issue persists, seek help.
  • OtherDeviceFaultcriticalCall your installer
    Manual (PDF)

    Model Incorrectly Set Fault

    Likely cause
    Product settings are not correct.
    What to do
    Seek help.
  • OverTempFaultcriticalCall your installer
    Manual (PDF)

    Over Temperature Fault

    Likely cause
    The inverter is overheating.
    What to do
    Check if the inverter and the ambient temperature exceeds the operating range. If the issue persists, seek help.
  • RcDeviceFaultcriticalCall your installer
    Manual (PDF)

    Residual Current Device Fault

    Likely cause
    Error detected in the residual current device.
    What to do
    Restart the inverter. If the issue persists, update the ARM software or return the program.
  • Arc FaultwarningCall your installer
    Manual (PDF)

    Arc Fault

    Likely cause
    Detection of electrical arcing.
    What to do
    Wait five minutes, if persistent contact SolaX.
  • ArcHW_FaultwarningCall your installer
    Manual (PDF)

    Arc Communication Lost Fault

    Likely cause
    Arc communication failure detected.
    What to do
    Contact SolaX for assistance.
  • ArcSelfTestFaultwarningCall your installer
    Manual (PDF)

    Arc Self-check Fault

    Likely cause
    The inverter failed its self-test for arc detection.
    What to do
    Wait 5 minutes then check again. Contact SolaX if it persists.
  • BusVoltFaultwarningCall your installer
    Manual (PDF)

    DC Bus Voltage Out of Normal Range

    Likely cause
    The DC voltage is outside of the normal operating range.
    What to do
    Check if the PV input voltage is within the operating range of the inverter. Disconnect PV wiring and reconnect. If the issue persists, seek help.
  • DcInjOcpwarningCall your installer
    Manual (PDF)

    DCI Overcurrent Protection Fault

    Likely cause
    Excessive current detected on the DC side.
    What to do
    Check connections, wait for the inverter to reset. Contact SolaX if it persists.
  • DclnjOCPwarningCall your installer
    Manual (PDF)

    DCI Overcurrent Protection Fault

    Likely cause
    Overcurrent detected in the DC input.
    What to do
    Wait for a while to check if the inverter is back to normal. If the issue persists, seek help.
  • Fan1 Warningwarning
    Manual (PDF)

    External Fan 1 Abnormal Warning

    Likely cause
    The first cooling fan may not be working properly.
    What to do
    Check if the fan is working. If the issue persists, seek help.
  • Fan2 Warningwarning
    Manual (PDF)

    External Fan 2 Abnormal Warning

    Likely cause
    The second cooling fan may not be working properly.
    What to do
    Check if the fan is working. If the issue persists, seek help.
  • GridFreqFaultwarning
    Manual (PDF)

    Grid Frequency Out of Range

    Likely cause
    Grid frequency is outside of acceptable limits.
    What to do
    Wait for a while and the system will reconnect when the utility is back to normal.
  • GridLostFaultwarning
    Manual (PDF)

    Grid Lost Fault

    Likely cause
    The inverter has lost connection with the grid.
    What to do
    Check if the mains cable is loose. Wait for a while and the system will reconnect when the utility is back to normal.
  • GridVolt10MFaultwarning
    Manual (PDF)

    Grid Overvoltage for Ten Minutes Fault

    Likely cause
    Grid voltage has been above the allowed limit for over ten minutes.
    What to do
    The system will reconnect automatically when the utility is back to normal.
  • GridVoltFaultwarning
    Manual (PDF)

    Grid Voltage Out of Range

    Likely cause
    Grid voltage is outside of acceptable limits.
    What to do
    Check if the mains cable is loose. Wait for a while and the system will reconnect when the utility is back to normal.
  • HardLimitFaultwarningCall your installer
    Manual (PDF)

    Hard Limit Fault (in Australian standard)

    Likely cause
    The inverter has reached a preset hard limit.
    What to do
    Wait for a while to check if the inverter is back to normal. If the issue persists, seek help.
  • InternalComFaultwarningCall your installer
    Manual (PDF)

    Internal Communication Fault

    Likely cause
    A communication issue within the inverter.
    What to do
    Restart the inverter to check if it is back to normal. If the issue persists, update the ARM software or return the program.
  • LowTempFaultwarning
    Manual (PDF)

    Low Temperature Fault

    Likely cause
    The inverter's ambient temperature is too low.
    What to do
    Check if the ambient temperature is within the operational limits. If the issue persists, seek help.
  • Meter Faultwarning
    Manual (PDF)

    Meter Fault

    Likely cause
    Error detected in the meter.
    What to do
    Check the connection of the meter. Check if the meter is in working order. If the issue persists, seek help.
  • PowerTypeFaultwarning
    Manual (PDF)

    Power Type Fault

    Likely cause
    Mismatch between expected and actual power type.
    What to do
    Check the version of ARM and DSP. Check the product SN number. If the issue persists, seek help.
  • PvConnDirFaultwarningCall your installer
    Manual (PDF)

    PV Direction Fault

    Likely cause
    Incorrect connections of the PV+/- sides.
    What to do
    Check if the PV+/- sides are connected correctly. If the issue persists, seek help.
  • PvVoltFaultwarningCall your installer
    Manual (PDF)

    PV Voltage Fault

    Likely cause
    PV input voltage is over the maximum limit.
    What to do
    Check if the PV input voltage is too high. Contact SolaX for assistance.
  • PWoltFaultwarningCall your installer
    Manual (PDF)

    PV Voltage Fault

    Likely cause
    The PV input voltage is above or below acceptable levels.
    What to do
    Check whether the PV is overvoltage. If the issue persists, seek help.
  • ResidualOCPwarningCall your installer
    Manual (PDF)

    Overcurrent Protection Fault

    Likely cause
    Potential overcurrent detected in the inverter.
    What to do
    Check the connections of the inverter. Wait for a while to check if the inverter is back to normal. If the issue persists, seek help.
  • SW OCP FaultwarningCall your installer
    Manual (PDF)

    Software Overcurrent Protection Fault

    Likely cause
    A software protection threshold has been exceeded.
    What to do
    Wait for a while to check if the inverter is back to normal. Disconnect PV and grid, then reconnect. If the issue persists, seek help.
  • TzFaultwarningCall your installer
    Manual (PDF)

    Over Current Fault

    Likely cause
    Inverter is experiencing excessive current.
    What to do
    Wait for about 10 seconds to check if the inverter is back to normal. Disconnect the DC switch and restart the inverter. If the issue persists, seek help.

More SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

X3-PRO-25K-G2 (AS4777-2 2020)

25 kW · 1φ

X3-PRO-20K-G2 (AS4777-2 2020)

20 kW · 1φ

X3-PRO-17K-G2 (AS4777-2 2020)

17 kW · 1φ

X3-Hybrid-15.0-D (AS4777-2 2020)

15 kW · 1φ

X3-MIC-15K-G2 (AS4777-2 2020)

14.999 kW · 1φ

X3-PRO-15K-G2 (AS4777-2 2020)

14.999 kW · 1φ

View all SolaX Power Network Technology (Zhe jiang) Co Ltd inverters

More from SolaX Power

Other CEC-approved products from SolaX Power available in Australia.

SolaX Power Batteries

AELIO-B100-AU

90 kWh · LFP

T-BAT HS10.8

9.9 kWh · LFP

T-BAT HS14.4

13.3 kWh · LFP

T-BAT HS18.0

16.5 kWh · LFP

T-BAT HS21.6

19.8 kWh · LFP

T-BAT HS25.2

23.2 kWh · LFP

View all SolaX Power batteries
View full SolaX Power manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters