Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. SolaX Power
  4. X1-BOOST-2.5K-G4

Solar inverter · SolaX Power · CEC approved April 2026

SolaX Power X1-BOOST-2.5K-G4

CEC listing: X1-BOOST-2.5K-G4 (AS4777-2 2020)

A 2.5 kW single-phase solar inverter.

Rated power
2.5kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

X1-BOOST-2.5K-G4: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
2.5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Solar
Runs solar only
Warranty
10yr
How long Solax Power Network Technology (Zhe jiang) Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the SolaX Power X1-BOOST-2.5K-G4, by section.

Full datasheet, by section
SpecificationValue
Physical
IP ratingIP66
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker20 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time3 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
8 Apr 2026
Approval expiry
13 Jan 2028
Status
Active
Listed for STCs
Yes

About SolaX Power

Years on the CEC list
5 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
137
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
10.6 kWh
Annual yield
3,878 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

5 years on the CEC list

How it compares

The SolaX Power X1-BOOST-2.5K-G4 against the closest-power inverters from other brands.

Specification
SolaX Power X1-BOOST-2.5K-G4SolaX Power
Afore AF2.5K-SL-1Afore
Enphase IQBATTERY-5P-3P-INT-2.50-1PEnphase
Rated power?2.5 kW2.5 kW2.5 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

SolaX Power X1-BOOST-2.5K-G4

This warranty covers defects in materials and workmanship for 10 years, excluding issues caused by poor installation or modifications. To make a claim, contact customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
Non-accredited installation, modification, tampering voids the warranty.
Environment limits
Salt spray, flood, temperatures above 60°C void coverage.
Read the official warranty document (PDF)

Fault & error codes — SolaX Power X1-BOOST-2.5K-G4

From the install manual

10 documented

Showing 10 of 10. The official install manual is the authoritative source — always confirm before acting.

  • IE:00020criticalCall your installer
    Manual (PDF)

    Isolation Fault

    Likely cause
    There is an insulation fault detected in the system.
    What to do
    Check the connections of the inverter. If issues persist, consult us for solutions.
  • IE:00021criticalCall your installer
    Manual (PDF)

    Over Temperature Fault

    Likely cause
    The inverter temperature has exceeded safe operating limits.
    What to do
    Check if the inverter and the ambient temperature exceeds the operating range. If this continues, consult us for solutions.
  • IE:00055criticalCall your installer
    Manual (PDF)

    Earth Fault

    Likely cause
    A problem has been detected with the earth connection.
    What to do
    Check the connections; ensure everything is connected properly. If issues persist, consult us for solutions.
  • IE:00001warning
    Manual (PDF)

    Over Current Fault

    Likely cause
    The inverter might be overloaded or experiencing a temporary surge.
    What to do
    Wait for about 10 seconds to check if the inverter is back to normal. If not, disconnect the DC switch and restart the inverter.
  • IE:00002warning
    Manual (PDF)

    Grid Lost Fault

    Likely cause
    The connection to the grid has been disrupted or is faulty.
    What to do
    Check if the mains cable is loose. Wait for a while; the system will reconnect when the utility is back to normal.
  • IE:00003warning
    Manual (PDF)

    Grid Voltage Out of Range

    Likely cause
    The grid voltage is either too high or too low.
    What to do
    Check if the mains cable is loose. Wait for a while; the system will reconnect when the utility is back to normal.
  • IE:00006warning
    Manual (PDF)

    Grid Frequency Out of Range

    Likely cause
    The grid frequency is not within acceptable limits.
    What to do
    Wait for a while; the system will reconnect when the utility is back to normal.
  • IE:00009warning
    Manual (PDF)

    PV Voltage Fault

    Likely cause
    The voltage from the photovoltaic (PV) input is too high.
    What to do
    Check whether the PV is overvoltage. If issues persist, consult us for solutions.
  • IE:00010warning
    Manual (PDF)

    DC Bus Voltage Out of Normal Range

    Likely cause
    The DC bus voltage is outside the acceptable range.
    What to do
    Check if the PV input voltage is within the operating range of the inverter. Disconnect PV wiring and reconnect.
  • IE:00012warning
    Manual (PDF)

    Grid Overvoltage for Ten Minutes Fault

    Likely cause
    The grid voltage has been above the allowable limit for an extended period.
    What to do
    The system will reconnect when the utility is back to normal.

More Solax Power Network Technology (Zhe jiang) Co Ltd inverters

X1-2.5K-S-N(L) (AS4777-2 2020)

2.5 kW · 1φ

X1-MINI-2.5K-G4 (AS4777-2 2020)

2.5 kW · 1φ

X1-2.0-S-N(L) (AS4777-2 2020)

2 kW · 1φ

X1-MINI-2.0K-G4 (AS4777-2 2020)

2 kW · 1φ

X1-3.0K-S-N(L) (AS4777-2 2020)

3 kW · 1φ

X1-BOOST-3K-G4 (AS4777-2 2020)

3 kW · 1φ

View all Solax Power Network Technology (Zhe jiang) Co Ltd inverters

More from SolaX Power

Other CEC-approved products from SolaX Power available in Australia.

SolaX Power Batteries

AELIO-B100-AU

90 kWh · LFP

T-BAT HS10.8

9.9 kWh · LFP

T-BAT HS14.4

13.3 kWh · LFP

T-BAT HS18.0

16.5 kWh · LFP

T-BAT HS21.6

19.8 kWh · LFP

T-BAT HS25.2

23.2 kWh · LFP

View all SolaX Power batteries
View full SolaX Power manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?