Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sofar
  4. SOFAR 50KTLX-G3

Solar inverter · Sofar · Not listed as CEC approved

Sofar SOFAR 50KTLX-G3

CEC listing: SOFAR 50KTLX-G3 (AS4777-2 2020)

A 50 kW single-phase solar inverter.

Rated power
50kWHow much solar it can run at once: a large roof
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter

Commercial-scale inverter

At 50 kW, this is built for businesses and large sites. A typical home inverter is 5–10 kW.

Browse home-size inverters →
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SOFAR 50KTLX-G3: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • The register doesn't currently list it as CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
50kW
How much solar it can turn into usable power at once
Max efficiency
98.8%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
3
3 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
10yr
How long Shenzhen SOFARSOLAR Co Ltd stands behind it

Full datasheet

Every figure on file for the Sofar SOFAR 50KTLX-G3, by section.

Full datasheet, by section
SpecificationValue
Power & output
Nominal power25 kW
Efficiency
Max efficiency98.8%
European efficiency98.2%
DC input & MPPT
MPPT trackers3
Physical
Weight36 kg
IP ratingIP65
Installation requirements
Top clearance539 mm
Side clearance50 mm
AC breaker80 A
Cable gauge25 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time2 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
2 Sept 2025
Approval expiry
20 June 2027
Status
Not listed
Listed for STCs
No (not listed)

About Sofar

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
126
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Website

www.sofarsolar.com
8 years on the CEC list

How it compares

The Sofar SOFAR 50KTLX-G3 against the closest-power inverters from other brands.

Specification
Sofar SOFAR 50KTLX-G3Sofar
Solplanet ASW50K-LT-G3Solplanet
Alpha ESS M50-INV-AUAlpha ESS
Rated power?50 kW50 kW50 kW
Max efficiency?98.8%Not on fileNot on file
MPPT trackers?3Not on fileNot on file
PhasesSingle-phaseThree-phaseThree-phase
TypeSolarSolarHybrid
Battery readyNoNoYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty terms and installation guidePDF, opens in a new tab

10-year inverter warranty

Sofar SOFAR 50KTLX-G3

This warranty covers defects in materials and workmanship for 10 years. It excludes damages from unauthorized installations or modifications. To make a claim, contact customer support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Non-accredited installation, modifications, tampering with the inverter.
Environment limits
-30°C to +60°C
Read the official warranty document (PDF)

Fault & error codes — Sofar SOFAR 50KTLX-G3

From the install manual

24 documented

Showing 24 of 24. The official install manual is the authoritative source — always confirm before acting.

  • 14criticalCall your installer
    Manual (PDF)

    The input current is too high

    Likely cause
    Exceeds permissible input current.
    What to do
    Inspect input current and cables; adjust if necessary; contact support if issues persist.
  • 19criticalCall your installer
    Manual (PDF)

    Grid current measurement error

    Likely cause
    Measurement discrepancies in grid current; may be temporary.
    What to do
    Switch DC switch OFF, wait 5 mins then ON; check if error persists; contact support if not resolved.
  • 56criticalCall your installer
    Manual (PDF)

    The insulation resistance is too low

    Likely cause
    Insulation failure between PV generator and ground.
    What to do
    Check insulation resistance; rectify short circuits immediately; consult professional.
  • ID005criticalCall your installer
    Manual (PDF)

    Charge Leakage Fault

    Likely cause
    Faulty wiring or inverter issue.
    What to do
    Check wiring for leaks and consult technician immediately.
  • ID008criticalCall your installer
    Manual (PDF)

    Island protection error

    Likely cause
    Possible unintentional disconnection from the grid.
    What to do
    Ensure there's connection with the grid, contact installer if unsure.
  • ID011criticalCall your installer
    Manual (PDF)

    Power grid line voltage error

    Likely cause
    Errors in the connection or conditions of the grid.
    What to do
    Verify wiring and connections, contact support for verification.
  • 01warning
    Manual (PDF)

    The voltage of the power grid is too high

    Likely cause
    Occasional high power grid voltage; equipment may return to normal automatically.
    What to do
    If the alarm occurs occasionally, wait for the grid voltage to return to normal. If frequent, check grid voltage and AC circuit breaker.
  • 02warning
    Manual (PDF)

    The voltage of the power grid is too low

    Likely cause
    Low grid voltage may cause frequent alarms; check connections.
    What to do
    Check if the grid voltage is within the permissible range; if it is, inspect AC circuit breaker and cables.
  • 03warning
    Manual (PDF)

    The grid frequency is too high

    Likely cause
    Frequent high frequency; normal operation when grid frequency returns to normal.
    What to do
    Ensure frequency is within permissible range; inspect AC circuit breaker and cables if frequent.
  • 04warningCall your installer
    Manual (PDF)

    The grid frequency is too low

    Likely cause
    Low grid frequency can lead to alarms; contact support for adjustments.
    What to do
    Contact technical support to adjust voltage and frequency limits with grid operator's approval.
  • 05warning
    Manual (PDF)

    The input voltage is too low

    Likely cause
    Insufficient PV modules; normal operation when voltage returns to normal.
    What to do
    Ensure enough PV modules are connected; check connections if necessary.
  • 09warning
    Manual (PDF)

    The input voltage is too high

    Likely cause
    Too many PV modules in series; normal operation when voltage is adjusted.
    What to do
    Check the wiring and reduce modules in series if needed; monitor operation.
  • 12warning
    Manual (PDF)

    Earthing error

    Likely cause
    Possible external factors affecting earth connection; may resolve soon.
    What to do
    If the error persists, check insulation resistance between PV generator and ground.
  • ID001warningCall your installer
    Manual (PDF)

    The grid voltage is too high

    Likely cause
    Inverter will automatically return to normal operating status when the electric grid's back to normal.
    What to do
    If the alarm occurs occasionally, check if grid voltage/frequency is within acceptable range. If yes, check AC circuit breaker and wiring.
  • ID002warningCall your installer
    Manual (PDF)

    The grid voltage is too low

    Likely cause
    Persistent low grid voltage might indicate a problem with the local utility.
    What to do
    Contact the local utility if the problem persists.
  • ID003warningCall your installer
    Manual (PDF)

    The grid frequency is too high

    Likely cause
    Potential temporary issue with the utility or configuration settings.
    What to do
    Check with the grid provider for issues and ensure settings are correct.
  • ID004warningCall your installer
    Manual (PDF)

    The grid frequency is too low

    Likely cause
    Could be a temporary issue or require inspection of utility.
    What to do
    Contact the local utility provider for assistance.
  • ID006warningCall your installer
    Manual (PDF)

    OVRT function is faulty

    Likely cause
    Abnormal grid conditions.
    What to do
    Check grid conditions and consult technical support if needed.
  • ID007warningCall your installer
    Manual (PDF)

    LVRT function is faulty

    Likely cause
    Could be a result of grid conditions affecting the inverter.
    What to do
    Contact technical support to analyze the situation.
  • ID009warningCall your installer
    Manual (PDF)

    Transient overvoltage of grid voltage 1

    Likely cause
    Could be due to grid abnormalities.
    What to do
    Monitor the grid voltage, consult technical support for issues.
  • ID010warningCall your installer
    Manual (PDF)

    Transient overvoltage of grid voltage 2

    Likely cause
    Similar to ID009, indicative of grid issues.
    What to do
    Keep an eye on your grid conditions, contact technical support as needed.
  • ID012warningCall your installer
    Manual (PDF)

    Invalid fault code

    Likely cause
    Refer to installation manual for current setting verification.
    What to do
    Review settings, ensure parameters are correct.
  • ID113warningCall your installer
    Manual (PDF)

    Internal temperature is too high

    Likely cause
    Insufficient cooling or ventilation around the inverter.
    What to do
    Ensure the inverter has proper airflow, check installation location.
  • ID114warningCall your installer
    Manual (PDF)

    AC frequency is too high

    Likely cause
    Check grid standards related to frequency norms.
    What to do
    Ensure the grid frequency complies with the inverter requirements.

More Shenzhen SOFARSOLAR Co Ltd inverters

SOFAR 45KTLX-G3 (AS4777-2 2020)

45 kW · 1φ

SOFAR 40KTLX-G3 (AS4777-2 2020)

40 kW · 1φ

SOFAR 36KTLX-G3 (AS4777-2 2020)

36 kW · 1φ

SOFAR 33KTLX-G3 (AS4777-2 2020)

33 kW · 1φ

SOFAR 30KTLX-G3 (AS4777-2 2020)

30 kW · 1φ

SOFAR 30KTLX-G3-A (AS4777-2 2020)

29.9 kW · 1φ

View all Shenzhen SOFARSOLAR Co Ltd inverters

More from Sofar

Other CEC-approved products from Sofar available in Australia.

Sofar Batteries

BTS 5K

4.992 kWh · LFP

BTS E10-DS5

9.984 kWh · LFP

BTS E15-DS5

14.976 kWh · LFP

BTS E20-DS5

19.968 kWh · LFP

BTS E5-DS5

4.992 kWh · LFP

BTS 5K

4.75 kWh

View all Sofar batteries
View full Sofar manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?