Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Sofar
  4. SOFAR 4.4KTLX-G3

Solar inverter · Sofar · CEC approval expired

Sofar SOFAR 4.4KTLX-G3

CEC listing: SOFAR 4.4KTLX-G3 (AS4777-2 2020)

A 4 kW single-phase solar inverter.

Rated power
4kWHow much solar it can run at once
Battery-ready
NoSolar-only: a battery later means a hybrid swap or a second inverter
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SOFAR 4.4KTLX-G3: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a solar-only inverter: adding a battery later means replacing it with a hybrid inverter, or keeping it and adding an AC-coupled battery, which in WA counts as an alteration with whole-of-site compliance.
  • It runs on a standard single-phase supply.
  • Its CEC approval has expired, so a new install with it wouldn't qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
4kW
How much solar it can turn into usable power at once
Max efficiency
98.4%
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Solar
Runs solar only
Warranty
10yr
How long Shenzhen SOFARSOLAR Co Ltd stands behind it

Full datasheet

Every figure on file for the Sofar SOFAR 4.4KTLX-G3, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency98.4%
European efficiency97.5%
DC input & MPPT
MPPT trackers2
Physical
Weight17 kg
IP ratingIP68
Operating temperature-40°C to 70°C

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
No
Backup capable
No
CEC approved
31 May 2022
Approval expiry
8 June 2026
Status
Not listed
Listed for STCs
No (not listed)

About Sofar

Years on the CEC list
8 years
Australian office
Not verified
Category
Mid-Tier
CEC-approved inverters
126
CEC-approved batteries
6
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
17.0 kWh
Annual yield
6,205 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.sofarsolar.com
8 years on the CEC list

How it compares

The Sofar SOFAR 4.4KTLX-G3 against the closest-power inverters from other brands.

Specification
Sofar SOFAR 4.4KTLX-G3Sofar
Afore AF4K-SLAfore
Afore HNS4000TLAfore
Rated power?4 kW4 kW4 kW
Max efficiency?98.4%Not on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeSolarHybridSolar
Battery readyNoYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Datasheet and warranty terms and installation guidePDF, opens in a new tab

10-year inverter warranty

Sofar SOFAR 4.4KTLX-G3

This warranty covers manufacturing defects for a period of 10 years. It excludes damages from incorrect installation, environmental factors, or unauthorized modifications. To make a claim, contact Sofarsolar's service department with the product details.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
The warranty may be voided if the product is installed by unaccredited installers, modified, or used with incompatible equipment.
Environment limits
The warranty does not cover damages caused by exposure to corrosive environments, such as saltwater or other aggressive atmospheres.
Read the official warranty document (PDF)

Fault & error codes — Sofar SOFAR 4.4KTLX-G3

From the install manual

8 documented

Showing 8 of 8. The official install manual is the authoritative source — always confirm before acting.

  • ID03criticalCall your installer
    Manual (PDF)

    The power grid frequency is too high

    Likely cause
    If the alarm occurs repeatedly, contact technical support to change the grid over-voltage, under-voltage, over frequency, under-frequency protection points after obtaining approval from the local electrical grid operator.
    What to do
    Contact technical support for adjustments.
  • ID06criticalCall your installer
    Manual (PDF)

    OVRT faulty

    Likely cause
    There are internal faults of inverter.
    What to do
    Turn OFF the DC switch, wait for 5 minutes, then turn ON the DC switch. If the fault persists, contact technical support.
  • ID12criticalCall your installer
    Manual (PDF)

    Inverter overvoltage

    Likely cause
    Internal fault within the inverter.
    What to do
    Contact technical support immediately.
  • ID13criticalCall your installer
    Manual (PDF)

    Output overcurrent hardware permanent fault

    Likely cause
    Prolonged overload conditions or failure in the power electronics.
    What to do
    Turn OFF the DC switch, wait for 5 minutes, then turn ON the DC switch to check if the issue resolves.
  • ID01warningCall your installer
    Manual (PDF)

    The power grid voltage is too high

    Likely cause
    If the alarm occurs occasionally, the possible cause is that the electric grid is abnormal occasionally, inverter automatically returns to normal operating status when the electric grid's back to normal.
    What to do
    Check the grid voltage and frequency. If it occurs frequently, contact technical support.
  • ID02warningCall your installer
    Manual (PDF)

    The power grid voltage is too low

    Likely cause
    If the alarm occurs frequently, check whether the grid voltage/frequency is within the acceptable range. If no, contact technical support.
    What to do
    Check the AC circuit breaker and AC wiring of the inverter.
  • ID04warningCall your installer
    Manual (PDF)

    The power grid frequency is too low

    Likely cause
    The alarm indicates low frequency, which may affect the operation.
    What to do
    Contact technical support to address low frequency issues.
  • ID05warningCall your installer
    Manual (PDF)

    GFCI Fault

    Likely cause
    If the fault occurs occasionally, the possible cause is that the external circuits are abnormal occasionally, inverter automatically returns to normal operating status after the fault is rectified.
    What to do
    Check the insulation resistance between the PV array and earth (ground).

More Shenzhen SOFARSOLAR Co Ltd inverters

ESI 4K-S1 (AS4777-2 2020)

4 kW · 1φ

HYD 4000-EP (AS4777-2 2020)

4 kW · 1φ

HYD 4000-ES (AS4777-2 2020)

4 kW · 1φ

SOFAR 4.4KTL-X (AS4777-2 2020)

4 kW · 1φ

SOFAR 4KTLM-G3 (AS4777-2 2020)

4 kW · 1φ

ESI 3.68K-S1 (AS4777-2 2020)

3.68 kW · 1φ

View all Shenzhen SOFARSOLAR Co Ltd inverters

More from Sofar

Other CEC-approved products from Sofar available in Australia.

Sofar Batteries

BTS 5K

4.992 kWh · LFP

BTS E10-DS5

9.984 kWh · LFP

BTS E15-DS5

14.976 kWh · LFP

BTS E20-DS5

19.968 kWh · LFP

BTS E5-DS5

4.992 kWh · LFP

BTS 5K

4.75 kWh

View all Sofar batteries
View full Sofar manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?