Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • info@solarbatteryperth.com.au
Explore your optionsCompare Products

Tools

  • Solar System Quiz
  • Side-by-Side Comparison
  • Savings Calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All Tools

Information

  • How it works
  • Resources
  • WA Rebates & Incentives
  • Battery price index
  • Synergy Tariffs
  • Financing
  • Getting Started
  • Buyer's Guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find Installers
  • Perth Suburbs
  • Brands
  • Contact Us
  • Common Questions
Privacy PolicyTerms of UseDisclaimerReview policyAffiliate DisclosureAccessibility

© 2026 Solar Battery AU, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead — the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Myenergi
  4. LIBBI-HS5D1-A

Hybrid inverter · Myenergi · CEC approved August 2026

Myenergi LIBBI-HS5D1-A

CEC listing: LIBBI-HS5D1-A (AS4777-2 2020)

A 5 kW single-phase hybrid inverter that is battery-ready.

Rated power
5kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from an installer from our network that covers your area.

LIBBI-HS5D1-A: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • It is CEC-approved, which a new install needs to qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
5kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Myenergi Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Myenergi LIBBI-HS5D1-A, by section.

Full datasheet, by section
SpecificationValue
Installation requirements
Top clearance500 mm
Side clearance600 mm
AC breaker3 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time10 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
20 Aug 2026
Approval expiry
20 Aug 2029
Status
Active
Listed for STCs
Yes

About Myenergi

Australian office
Not verified
Category
Unknown
CEC-approved inverters
1
CEC-approved batteries
1
View full profile →
Explore your options

Compare quotes from installers you choose

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
21.3 kWh
Annual yield
7,756 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

0 years in Australian market

How it compares

The Myenergi LIBBI-HS5D1-A against the closest-power inverters from other brands.

Specification
Myenergi LIBBI-HS5D1-AMyenergi
Energizer FORCE 5.0HSEnergizer
Energizer Force 5.0HT+Energizer
Rated power?5 kW5 kW5 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesSingle-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsPDF, opens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Myenergi LIBBI-HS5D1-A

This warranty covers defects for 10 years, allowing one transfer. Key exclusion includes unauthorized repairs. To claim, contact support.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Pro-rata — value reduces with age
If you sell the home
Transfers to the next homeowner
What voids it
Warranty void if modifications, tampering, or unauthorized repairs occur.
Environment limits
Not installed in environments where temperatures exceed 50°C or humidity exceeds 95%.
Read the official warranty document (PDF)

Fault & error codes — Myenergi LIBBI-HS5D1-A

From the install manual

62 documented

Showing 62 of 62. The official install manual is the authoritative source — always confirm before acting.

  • 107criticalCall your installer
    Manual (PDF)

    Master Lost

    Likely cause
    Load control device has been lost, device has stopped to be safe.
    What to do
    Ensure master device is powered on and check pairing of all devices.
  • 152criticalCall your installer
    Manual (PDF)

    Inverter Overvoltage

    Likely cause
    The inverter reports high grid voltage.
    What to do
    Contact myenergi Tech Support.
  • 153criticalCall your installer
    Manual (PDF)

    Inverter Under Frequency

    Likely cause
    The inverter reports low grid frequency.
    What to do
    Contact myenergi Tech Support.
  • 154criticalCall your installer
    Manual (PDF)

    Inverter Over Frequency

    Likely cause
    The inverter reports high grid frequency.
    What to do
    Contact myenergi Tech Support.
  • 156criticalCall your installer
    Manual (PDF)

    Battery Lost

    Likely cause
    Communications between the battery and inverter have failed.
    What to do
    Check battery is turned on and connections are secure.
  • 157criticalCall your installer
    Manual (PDF)

    Battery Undervoltage

    Likely cause
    Battery voltage is under threshold.
    What to do
    Reboot battery and check for any issues.
  • 159criticalCall your installer
    Manual (PDF)

    Battery Voltage High

    Likely cause
    Reporting high battery voltage.
    What to do
    Reboot battery and contact support if the issue persists.
  • 160criticalCall your installer
    Manual (PDF)

    Overload

    Likely cause
    Inverter circuit overloaded, demand exceeds inverter capacity.
    What to do
    Turn off loads powered by backup circuit.
  • 161criticalCall your installer
    Manual (PDF)

    GFCI Over Threshold

    Likely cause
    Inverter internal protection triggered due to internal fault.
    What to do
    Contact myenergi Tech Support.
  • 165criticalCall your installer
    Manual (PDF)

    BMS Discharge Over Current

    Likely cause
    Battery Management System reported discharge over current.
    What to do
    Reboot battery and contact support if the issue persists.
  • 166criticalCall your installer
    Manual (PDF)

    BMS Charge Over Current

    Likely cause
    Battery Management System reported charge over current.
    What to do
    Reboot battery and contact support if issue remains.
  • 167criticalCall your installer
    Manual (PDF)

    BMS Over Voltage

    Likely cause
    Battery Management System reported over voltage condition.
    What to do
    Reboot battery and contact support if necessary.
  • 170criticalCall your installer
    Manual (PDF)

    Battery Voltage Imbalance

    Likely cause
    Voltage imbalance detected in battery cells.
    What to do
    Reboot battery and check connections.
  • 171criticalCall your installer
    Manual (PDF)

    BMS Communications Fault

    Likely cause
    Communication failure between battery and inverter.
    What to do
    Check communication cables and connections.
  • 172criticalCall your installer
    Manual (PDF)

    BMS Under Voltage

    Likely cause
    BMS detected under voltage condition.
    What to do
    Reboot battery and verify connections.
  • 174criticalCall your installer
    Manual (PDF)

    BMS Voltage High

    Likely cause
    Battery Management System reported high voltage condition.
    What to do
    Reboot battery and monitor status.
  • 175criticalCall your installer
    Manual (PDF)

    BMS Temperature High

    Likely cause
    Battery Management System reported high temperature.
    What to do
    Check ambient temperature and contact support if necessary.
  • 183criticalCall your installer
    Manual (PDF)

    Inv Comms Lost

    Likely cause
    Communication loss between inverter and controller.
    What to do
    Check RS485 connections and reboot.
  • 184criticalCall your installer
    Manual (PDF)

    Controller Undervoltage

    Likely cause
    Controller voltage below operational threshold.
    What to do
    Contact DNO and check power supply.
  • 185criticalCall your installer
    Manual (PDF)

    Controller Overvoltage

    Likely cause
    Controller voltage above operational threshold.
    What to do
    Contact DNO and check power supply.
  • 186criticalCall your installer
    Manual (PDF)

    Controller Under Frequency

    Likely cause
    Controller frequency below operational threshold.
    What to do
    Contact DNO and check power supply.
  • 187criticalCall your installer
    Manual (PDF)

    Controller Over Frequency

    Likely cause
    Controller frequency above operational threshold.
    What to do
    Contact DNO and check power supply.
  • 202criticalCall your installer
    Manual (PDF)

    Internal Voltage Short

    Likely cause
    Voltage short detected internally.
    What to do
    Power down the system and contact support.
  • 207criticalCall your installer
    Manual (PDF)

    Bus Short Fault

    Likely cause
    Short circuit detected on the bus.
    What to do
    Power down immediately and check wiring.
  • 208criticalCall your installer
    Manual (PDF)

    PV ISO Under

    Likely cause
    Insulation below acceptable limits on PV inputs.
    What to do
    Power down system and check insulation.
  • 209criticalCall your installer
    Manual (PDF)

    PV Input Short Circuit

    Likely cause
    Short circuit detected on PV inputs.
    What to do
    Power down system and check PV inputs.
  • 210criticalCall your installer
    Manual (PDF)

    Bypass Relay Fault

    Likely cause
    Error with the bypass relay identified.
    What to do
    Power down and contact support for further action.
  • 211criticalCall your installer
    Manual (PDF)

    Inverter Overcurrent

    Likely cause
    Inverter exceeding current capabilities.
    What to do
    Check loads and power down if necessary.
  • 212criticalCall your installer
    Manual (PDF)

    Inverter DC Over

    Likely cause
    Excessive DC voltage detected at inverter.
    What to do
    Power down the system and contact support.
  • 215criticalCall your installer
    Manual (PDF)

    Grid Relay Fault

    Likely cause
    Fault detected in the grid relay.
    What to do
    Power down the system and have it inspected.
  • 216criticalCall your installer
    Manual (PDF)

    Discharge Overcurrent

    Likely cause
    Discharge current exceeds limits.
    What to do
    Check loads and power down if necessary.
  • 217criticalCall your installer
    Manual (PDF)

    Charge Overcurrent

    Likely cause
    Charging current exceeding limits.
    What to do
    Contact support if issues persist.
  • 219criticalCall your installer
    Manual (PDF)

    Inverter Abnormal

    Likely cause
    Inverter has detected abnormal conditions.
    What to do
    Power down and check inverter operations.
  • 220criticalCall your installer
    Manual (PDF)

    EPS Relay Fault

    Likely cause
    Error detected in EPS relay.
    What to do
    Power down and consult support for repair.
  • 232criticalCall your installer
    Manual (PDF)

    SCI Fault

    Likely cause
    Fault detected in the SCI functionality.
    What to do
    Power down and consult technical support immediately.
  • 101warning
    Manual (PDF)

    Battery Empty

    Likely cause
    The minimum state of charge has been met.
    What to do
    Recharge the battery immediately.
  • 106warning
    Manual (PDF)

    Grid CT Lost

    Likely cause
    Grid readings have been lost, device has stopped to be safe.
    What to do
    Check if the grid CT is connected to the controller.
  • 151warning
    Manual (PDF)

    Inverter Undervoltage

    Likely cause
    The inverter reports low grid voltage.
    What to do
    Check inverter connection to the grid.
  • 158warning
    Manual (PDF)

    Battery Voltage Low

    Likely cause
    Reporting low battery voltage.
    What to do
    Reboot battery and check the charging status.
  • 163warningCall your installer
    Manual (PDF)

    Fan Fault

    Likely cause
    Inverter fan fault detected.
    What to do
    Contact myenergi Tech Support.
  • 164warningCall your installer
    Manual (PDF)

    Bat Under Capacity

    Likely cause
    Battery power is insufficient to discharge.
    What to do
    Contact myenergi Tech Support.
  • 168warningCall your installer
    Manual (PDF)

    BMS Over Temperature

    Likely cause
    Battery Management System reported high temperature.
    What to do
    Check ambient temperature and contact support.
  • 169warningCall your installer
    Manual (PDF)

    BMS Discharge Temperature Low

    Likely cause
    Battery Management System reported low discharge temperature.
    What to do
    Check ambient temperature.
  • 173warningCall your installer
    Manual (PDF)

    BMS Charge Temperature Low

    Likely cause
    Battery Management System reported low charge temperature.
    What to do
    Check ambient temperature and contact support if necessary.
  • 179warning
    Manual (PDF)

    Grid CT Polarity

    Likely cause
    Grid CT may be incorrectly installed.
    What to do
    Check Grid CT installation and correct if necessary.
  • 201warningCall your installer
    Manual (PDF)

    Soft Timeout

    Likely cause
    Device timeout error, potential system inactivity.
    What to do
    Power down and restart the system.
  • 203warningCall your installer
    Manual (PDF)

    GFCI Sensor Fault

    Likely cause
    Error from GFCI sensor detected.
    What to do
    Power down system and check GFCI sensor.
  • 205warningCall your installer
    Manual (PDF)

    Bus Low Fault

    Likely cause
    Low voltage detected on the bus.
    What to do
    Power down and check connections.
  • 206warningCall your installer
    Manual (PDF)

    Bus High Fault

    Likely cause
    High voltage detected on the bus.
    What to do
    Power down and check connections.
  • 213warningCall your installer
    Manual (PDF)

    Ambient Over Temperature

    Likely cause
    Ambient temperature exceeds operating limits.
    What to do
    Check installation environment and mitigate overheating.
  • 214warningCall your installer
    Manual (PDF)

    Sink Over Temperature

    Likely cause
    Temperature at the sink exceeds operational threshold.
    What to do
    Check cooling and installation conditions.
  • 57warning
    Manual (PDF)

    Harvi Lost Comms

    Likely cause
    Harvi has not been heard from for over 24 hours.
    What to do
    Check if Harvi is powered on and re-pair devices if necessary.
  • 58warning
    Manual (PDF)

    Generation CT Polarity

    Likely cause
    Polarity of the generation CT is reversed.
    What to do
    Correct the polarity of the generation CT installation.
  • 102info
    Manual (PDF)

    Battery Full

    Likely cause
    The maximum state of charge has been met.
    What to do
    Battery is fully charged, no action required.
  • 251info
    Manual (PDF)

    Upgrading DSP

    Likely cause
    DSP upgrade has started.
    What to do
    No action required, process will complete automatically.
  • 252info
    Manual (PDF)

    Upgrading ARM

    Likely cause
    ARM upgrade has started.
    What to do
    No action required, process will complete automatically.
  • 51info
    Manual (PDF)

    Max Charge Grid Limit

    Likely cause
    The battery's charge rate is being limited by the grid limit or grid limit is exceeded while libbi is in stop mode.
    What to do
    Monitor grid settings and ensure proper connection to the grid.
  • 52info
    Manual (PDF)

    Max Drain Grid Limit

    Likely cause
    The battery's drain rate is being limited by the grid limit.
    What to do
    Check if the grid limit settings are correctly configured.
  • 53info
    Manual (PDF)

    Max Charge Device Limit

    Likely cause
    The battery's charge rate is being limited by the device limit.
    What to do
    Review device limit settings on the controller.
  • 54info
    Manual (PDF)

    Max Drain Device Limit

    Likely cause
    The battery's drain rate is being limited by the device limit.
    What to do
    Check device limits and adjust if necessary.
  • 55info
    Manual (PDF)

    Max Charge Group Limit

    Likely cause
    The battery's charge rate is being limited by a group limit.
    What to do
    Verify the group limits set on the system.
  • 56info
    Manual (PDF)

    Max Drain Group Limit

    Likely cause
    The battery's drain rate is being limited by a group limit.
    What to do
    Confirm the group limits are correctly set.

More from Myenergi

Other CEC-approved products from Myenergi available in Australia.

Myenergi Batteries

LIBBI-BM5D1-A

4.6 kWh · LFP

View all Myenergi batteries
View full Myenergi manufacturer profile

Want to take the next step?

Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?