Hybrid inverter · Myenergi · CEC approved August 2026
CEC listing: LIBBI-HS5D1-A (AS4777-2 2020)
A 5 kW single-phase hybrid inverter that is battery-ready.
Read from the figures on this page. No review written yet.
The numbers that matter for a home. The full datasheet is below.
Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us
Every figure on file for the Myenergi LIBBI-HS5D1-A, by section.
| Specification | Value |
|---|---|
| Installation requirements | |
| Top clearance | 500 mm |
| Side clearance | 600 mm |
| AC breaker | 3 A |
| Cable gauge | 4 mm² |
| Earthing method | TN-S |
| DNSP pre-approval | Yes |
| Estimated install time | 10 hrs |
Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.
Compare quotes from installers you choose
Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.
Estimate for a full-size array on this inverter
At 5 peak sun hours a day (BOM) with a 15% system derate.
The Myenergi LIBBI-HS5D1-A against the closest-power inverters from other brands.
| Specification | Myenergi LIBBI-HS5D1-AMyenergi | Energizer FORCE 5.0HSEnergizer | Energizer Force 5.0HT+Energizer |
|---|---|---|---|
| Rated power? | 5 kW | 5 kW | 5 kW |
| Max efficiency? | Not on file | Not on file | Not on file |
| MPPT trackers? | Not on file | Not on file | Not on file |
| Phases | Single-phase | Single-phase | Three-phase |
| Type | Hybrid | Hybrid | Hybrid |
| Battery ready | Yes | Yes | Yes |
| Warranty | 10 years | Not on file | Not on file |
Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.
This warranty covers defects for 10 years, allowing one transfer. Key exclusion includes unauthorized repairs. To claim, contact support.
AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.
From the install manual
Showing 62 of 62. The official install manual is the authoritative source — always confirm before acting.
107criticalCall your installerMaster Lost
152criticalCall your installerInverter Overvoltage
153criticalCall your installerInverter Under Frequency
154criticalCall your installerInverter Over Frequency
156criticalCall your installerBattery Lost
157criticalCall your installerBattery Undervoltage
159criticalCall your installerBattery Voltage High
160criticalCall your installerOverload
161criticalCall your installerGFCI Over Threshold
165criticalCall your installerBMS Discharge Over Current
166criticalCall your installerBMS Charge Over Current
167criticalCall your installerBMS Over Voltage
170criticalCall your installerBattery Voltage Imbalance
171criticalCall your installerBMS Communications Fault
172criticalCall your installerBMS Under Voltage
174criticalCall your installerBMS Voltage High
175criticalCall your installerBMS Temperature High
183criticalCall your installerInv Comms Lost
184criticalCall your installerController Undervoltage
185criticalCall your installerController Overvoltage
186criticalCall your installerController Under Frequency
187criticalCall your installerController Over Frequency
202criticalCall your installerInternal Voltage Short
207criticalCall your installerBus Short Fault
208criticalCall your installerPV ISO Under
209criticalCall your installerPV Input Short Circuit
210criticalCall your installerBypass Relay Fault
211criticalCall your installerInverter Overcurrent
212criticalCall your installerInverter DC Over
215criticalCall your installerGrid Relay Fault
216criticalCall your installerDischarge Overcurrent
217criticalCall your installerCharge Overcurrent
219criticalCall your installerInverter Abnormal
220criticalCall your installerEPS Relay Fault
232criticalCall your installerSCI Fault
101warningBattery Empty
106warningGrid CT Lost
151warningInverter Undervoltage
158warningBattery Voltage Low
163warningCall your installerFan Fault
164warningCall your installerBat Under Capacity
168warningCall your installerBMS Over Temperature
169warningCall your installerBMS Discharge Temperature Low
173warningCall your installerBMS Charge Temperature Low
179warningGrid CT Polarity
201warningCall your installerSoft Timeout
203warningCall your installerGFCI Sensor Fault
205warningCall your installerBus Low Fault
206warningCall your installerBus High Fault
213warningCall your installerAmbient Over Temperature
214warningCall your installerSink Over Temperature
57warningHarvi Lost Comms
58warningGeneration CT Polarity
102infoBattery Full
251infoUpgrading DSP
252infoUpgrading ARM
51infoMax Charge Grid Limit
52infoMax Drain Grid Limit
53infoMax Charge Device Limit
54infoMax Drain Device Limit
55infoMax Charge Group Limit
56infoMax Drain Group Limit
Other CEC-approved products from Myenergi available in Australia.
Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.
About this data
All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.