Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead — the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. RoyPow
  4. SUN8000T-E/I

Hybrid inverter · RoyPow · CEC approved September 2025

RoyPow SUN8000T-E/I

CEC listing: SUN8000T-E/I (AS4777-2 2020)

An 8 kW three-phase hybrid inverter that is battery-ready.

Rated power
8kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from an installer from our network that covers your area.

SUN8000T-E/I: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
NoDEBS pays for exports only when the inverter is 5 kW or less

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It needs a three-phase supply, so check your switchboard or ask your installer.
  • It is CEC-approved, which a new install needs to qualify for STCs.
  • We hold no captured datasheet for this model yet, so the specs below come from the CEC register only.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
8kW
How much solar it can turn into usable power at once
Max efficiency
87.0%
How much of the solar you make reaches the house
Phases
3-phase
Needs a three-phase supply, so check your switchboard
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Huizhou RoyPow Technology Co Ltd stands behind it

Full datasheet

Every figure on file for the RoyPow SUN8000T-E/I, by section.

Full datasheet, by section
SpecificationValue
Efficiency
Max efficiency87%
Physical
Dimensions (H×W×D)165 × 86 × 260 mm
Weight2.4 kg
IP ratingIP21
Installation requirements
Top clearance300 mm
Side clearance300 mm
AC breaker63 A
Cable gauge4 mm²
Earthing methodTN-S
DNSP pre-approvalNo
Estimated install time8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
16 Sept 2025
Approval expiry
16 Sept 2028
Status
Active
Listed for STCs
Yes

About RoyPow

Years in the Australian market
1 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
9
CEC-approved batteries
20
View full profile →
Explore your options

Compare quotes from installers you choose

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

ESM compliant
Check

Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
34.0 kWh
Annual yield
12,410 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

1 years in Australian market

How it compares

The RoyPow SUN8000T-E/I against the closest-power inverters from other brands.

Specification
RoyPow SUN8000T-E/IRoyPow
Energizer Force 8.0HS+Energizer
Energizer Force 8.0HT+Energizer
Rated power?8 kW8 kW8 kW
Max efficiency?87.0%Not on fileNot on file
MPPT trackers?Not on fileNot on fileNot on file
PhasesThree-phaseSingle-phaseThree-phase
TypeHybridHybridHybrid
Battery readyYesYesYes
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • Warranty termsOpens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

RoyPow SUN8000T-E/I

The warranty lasts for 10 years covering full replacement. It does not transfer to new owners. For claims, refer to the warranty document.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Does not transfer with the home
What voids it
non-accredited installation, modification, tampering
Read the official warranty document (PDF)

Fault & error codes — RoyPow SUN8000T-E/I

From the install manual

9 documented

Showing 9 of 9. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    Grid quick test Fail

    Likely cause
    The L1/L2/L3 voltage peak is greater than 426.0382V, or the R/S/T voltage instantaneous value is greater than 405V.
    What to do
    Check the grid voltage and ensure it's within the allowable range. Contact the local power operator if not.
  • 11criticalCall your installer
    Manual (PDF)

    Bus Short-circuit Fail

    Likely cause
    Bus+ or Bus- voltage is significantly reduced, indicating a serious failure.
    What to do
    Contact after-sales service for maintenance immediately.
  • 12criticalCall your installer
    Manual (PDF)

    Bus Rapid LowVolt

    Likely cause
    Bus voltage is continuously below threshold levels.
    What to do
    Turn off the inverter, wait, then restart. Contact support if unresolved.
  • 2criticalCall your installer
    Manual (PDF)

    Grid volt. 10-min average

    Likely cause
    The ten-minute average value of the effective value of the L1/L2/L3 voltage is above safety standards.
    What to do
    Check the grid voltage average. Contact the local power operator if necessary.
  • 3criticalCall your installer
    Manual (PDF)

    Grid L1/L2/L3 OV level1

    Likely cause
    Effective value of the L1/L2/L3 voltage exceeds the overvoltage protection value.
    What to do
    Verify the grid connection and ensure all connections are proper.
  • 4criticalCall your installer
    Manual (PDF)

    Grid L1/L2/L3 UV level1

    Likely cause
    The RMS of the L1/L2/L3 voltage is less than the undervoltage protection value.
    What to do
    Check the grid voltage levels. Contact the power provider if necessary.
  • 46criticalCall your installer
    Manual (PDF)

    Mppt1/MPPT2 hardware OC shutdown

    Likely cause
    Hardware over current fault occurs continuously for 300ms.
    What to do
    Turn off the inverter, wait, then restart. Contact support if unresolved.
  • 5criticalCall your installer
    Manual (PDF)

    Grid OverFreq level1

    Likely cause
    Grid frequency is exceeding the over-frequency protection thresholds.
    What to do
    Monitor grid frequency and check for abnormalities.
  • 6criticalCall your installer
    Manual (PDF)

    Grid UnderFreq level1

    Likely cause
    Grid frequency is falling below the under-frequency protection thresholds.
    What to do
    Measure grid frequency and ensure proper operation.

More Huizhou RoyPow Technology Co Ltd inverters

SUN10000T-E/I (AS4777-2 2020)

10 kW · 3φ

SUN12000T-E/I (AS4777-2 2020)

12 kW · 3φ

SUN15000T-E/I (AS4777-2 2020)

15 kW · 3φ

SUN5000S-E/I (AS4777-2 2020)

5 kW · 1φ

SUN4600S-E/I (AS4777-2 2020)

4.6 kW · 1φ

SUN4000S-E/I (AS4777-2 2020)

4 kW · 1φ

View all Huizhou RoyPow Technology Co Ltd inverters

More from RoyPow

Other CEC-approved products from RoyPow available in Australia.

RoyPow Batteries

2*RBmax3.8MH

7.06 kWh · LFP

2*RBmax5.1L

9.58 kWh · LFP

2*RBmax5.1L2

9.58 kWh · LFP

2*RBmax5.5MH

10.18 kWh · LFP

3*RBmax3.8MH

10.6 kWh · LFP

3*RBmax5.1L

14.37 kWh · LFP

View all RoyPow batteries
View full RoyPow manufacturer profile

Want to take the next step?

Get a quote from an installer from our network that covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?