Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Inverters
  3. Hinen
  4. H3600-EU

Hybrid inverter · Hinen · CEC approved February 2024

Hinen H3600-EU

CEC listing: H3600-EU (AS4777-2 2020)

A 3.7 kW single-phase hybrid inverter that is battery-ready and listed for battery storage on Synergy's list.

Listed for battery storage on Synergy's list
YesSynergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
Rated power
3.7kWHow much solar it can run at once
Battery-ready
YesHybrid: a battery plugs straight in, no second box
Datasheet (PDF)

Get this inverter quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

H3600-EU: the short answer

Feed-in credits (DEBS)DEBS pays for exports only when the inverter is 5 kW or less
YesDEBS pays for exports only when the inverter is 5 kW or less
Listed for battery storage on Synergy's listMatched to this exact model. Other scheme conditions apply
YesMatched to this exact model. Other scheme conditions apply

What we can tell you

Read from the figures on this page. No review written yet.

  • It is a hybrid inverter: solar and a battery run from the one unit, so adding a battery later doesn't need a second box.
  • It runs on a standard single-phase supply.
  • Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.
  • It is CEC-approved, which a new install needs to qualify for STCs.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Rated power
3.7kW
How much solar it can turn into usable power at once
Max efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the solar you make reaches the house
Phases
Single
Runs on a standard single-phase supply
MPPT trackers
2
2 roof faces can be tuned independently
Type
Hybrid
Runs solar and a battery from one unit
Warranty
10yr
How long Dongguan Hinen New Energy Technology Co Ltd stands behind it

Not on file: we don’t have this figure from the manufacturer’s documents yet, so we leave it blank rather than print a typical value. Ask your installer to confirm it on the quote. Seen it in a document? Tell us

Full datasheet

Every figure on file for the Hinen H3600-EU, by section.

Full datasheet, by section
SpecificationValue
DC input & MPPT
MPPT trackers2
Physical
IP ratingIP65
Rebate eligibility
Listed for battery storage on Synergy's listYes
Installation requirements
Top clearance300 mm
Side clearance200 mm
AC breaker40 A
Cable gauge6 mm²
Earthing methodTN-S
DNSP pre-approvalYes
Estimated install time5 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Features and CEC approval

Battery compatible
Yes
Backup capable
Yes
CEC approved
13 Feb 2024
Approval expiry
13 Feb 2027
Status
Active
Listed for STCs
Yes

About Hinen

Years on the CEC list
2 years
Australian office
Not verified
Category
Budget
CEC-approved inverters
33
CEC-approved batteries
39
View full profile →
Explore your options

Get a quote from an installer sourced from the WA (Synergy/Plenti) approved list

  • Compare with other inverters→
  • Already have a quote? Check it→

WA compliance

Listed for battery storage on Synergy's list
Yes
ESM compliant
Check

Listed for battery storage on Synergy's list. Synergy's Supported Solutions List covers inverters approved for control. A battery system needs an inverter with a battery-storage (DER-Storage) listing on this list to be eligible for the WA Battery Scheme. A listing for generation only doesn't count. Other scheme conditions apply.Western Power approval is required for every grid-connected install. Under Emergency Solar Management, a new system must be remotely manageable, or take an export limit instead. Ask your installer to confirm this inverter’s ESM status.

Perth performance

Estimate for a full-size array on this inverter

Daily yield
15.6 kWh
Annual yield
5,709 kWh

At 5 peak sun hours a day (BOM) with a 15% system derate.

Website

www.hinen.com
2 years on the CEC list

How it compares

The Hinen H3600-EU against the closest-power inverters from other brands.

Specification
Hinen H3600-EUHinen
Energizer FORCE 3.7HSEnergizer
Solplanet ASW3680-SSolplanet
Rated power?3.68 kW3.68 kW3.68 kW
Max efficiency?Not on fileNot on fileNot on file
MPPT trackers?2Not on fileNot on file
PhasesSingle-phaseSingle-phaseSingle-phase
TypeHybridHybridSolar
Battery readyYesYesNo
Warranty10 yearsNot on fileNot on file

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Documents

  • DatasheetOpens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guideOpens in a new tab
  • User manualOpens in a new tab
  • Compliance certificatePDF, opens in a new tab

10-year inverter warranty

Hinen H3600-EU

Coverage includes defects for 5 years. Non-compliance with installation guidelines voids the warranty. Claim via support email.

AI-summarised from the manufacturer warranty document. Always confirm against the linked PDF before relying on it for a claim.

Coverage shape
Full-replacement coverage
If you sell the home
Transfers to the next homeowner
What voids it
Warranty voided by non-accredited installations, modifications, or unauthorized repairs.
Environment limits
Installation in extreme temperature environments or exposure to salt spray voids the warranty.
Read the official warranty document (PDF)

Fault & error codes — Hinen H3600-EU

From the install manual

17 documented

Showing 17 of 17. The official install manual is the authoritative source — always confirm before acting.

  • 108criticalCall your installer
    Manual (PDF)

    NTC Temperature too high

    Likely cause
    Inverter temperature exceeds normal operating range
    What to do
    Check temperature, restart the inverter if normal.
  • 109criticalCall your installer
    Manual (PDF)

    Bus voltage abnormal

    Likely cause
    Improper voltage levels in the system
    What to do
    Restart inverter; contact manufacturer if error persists.
  • 110criticalCall your installer
    Manual (PDF)

    Communication fault

    Likely cause
    Issues with inverter communication board wiring
    What to do
    Check communications wiring, restart inverter.
  • 200criticalCall your installer
    Manual (PDF)

    No AC Connection

    Likely cause
    AC wiring problems
    What to do
    Check AC wiring after shutdown.
  • 201criticalCall your installer
    Manual (PDF)

    AC V Outrange

    Likely cause
    Grid voltage out of expected range
    What to do
    Verify grid voltage, contact manufacturer if necessary.
  • 202criticalCall your installer
    Manual (PDF)

    AC F Outrange

    Likely cause
    Grid frequency is out of expected range
    What to do
    Restart inverter; contact manufacturer if error persists.
  • 205criticalCall your installer
    Manual (PDF)

    CT LN Reversed

    Likely cause
    CT connection is reversed
    What to do
    Check CT connections; correct and restart inverter.
  • 300criticalCall your installer
    Manual (PDF)

    EPS OP Short Fault

    Likely cause
    Issue with EPS output short circuit
    What to do
    Restart inverter; contact manufacturer if issue persists.
  • 302criticalCall your installer
    Manual (PDF)

    Off-grid output voltage is too low

    Likely cause
    Low voltage in off-grid mode
    What to do
    Restart inverter; ensure off-grid conditions are met.
  • 303criticalCall your installer
    Manual (PDF)

    Off-grid output voltage is too High

    Likely cause
    High voltage in off-grid mode
    What to do
    Restart inverter; ensure loads are connected properly.
  • 401criticalCall your installer
    Manual (PDF)

    The DC input voltage is exceeding the maximum tolerable value

    Likely cause
    Insufficient management of DC input
    What to do
    Disconnect DC switch and check voltage levels.
  • 500criticalCall your installer
    Manual (PDF)

    BMS Communication fault

    Likely cause
    Issues with BMS communication wiring
    What to do
    Check wiring and restart inverter.
  • 502criticalCall your installer
    Manual (PDF)

    Battery voltage low

    Likely cause
    Battery discharging beyond thresholds
    What to do
    Check battery voltage, rectify issues before use.
  • 503criticalCall your installer
    Manual (PDF)

    Battery Voltage High

    Likely cause
    Improper battery settings or faults
    What to do
    Restart inverter; replace battery if issues persist.
  • 504criticalCall your installer
    Manual (PDF)

    Battery temperature out of specified range for charge or discharge

    Likely cause
    Incompatible operating conditions
    What to do
    Check battery temperature and restart if safe.
  • 505criticalCall your installer
    Manual (PDF)

    Battery terminals reversed

    Likely cause
    Improper connection of battery terminals
    What to do
    Check and rectify battery connections.
  • 506criticalCall your installer
    Manual (PDF)

    Battery terminal open (only for lithium battery)

    Likely cause
    Open circuit connection on battery
    What to do
    Check connections, rectify the terminal issues.

More Dongguan Hinen New Energy Technology Co Ltd inverters

A3600S (AS4777-2 2020)

3.6 kW · 1φ

A3600S-E (AS4777-2 2020)

3.6 kW · 1φ

AC3600S (AS4777-2 2020)

3.6 kW · 1φ

AC3600S-E (AS4777-2 2020)

3.6 kW · 1φ

H4000-EU (AS4777-2 2020)

4 kW · 1φ

H3000-EU (AS4777-2 2020)

3 kW · 1φ

View all Dongguan Hinen New Energy Technology Co Ltd inverters

More from Hinen

Other CEC-approved products from Hinen available in Australia.

Hinen Batteries

B14400-H

13.68 kWh · LFP

B14400-H x2

27.36 kWh · LFP

B14400-H x3

41.04 kWh · LFP

B14400-H x4

54.72 kWh · LFP

B14400-H x5

68.4 kWh · LFP

B14400-HW

13.68 kWh · LFP

View all Hinen batteries
View full Hinen manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

About this data

All inverter specifications are sourced from the CEC Approved Products Register. Specifications are provided as published by the CEC and may differ from manufacturer datasheets. Verify current specifications with the manufacturer or your installer before purchasing. Not all listed models may be currently available in Western Australia.

Explore your optionsCompare inverters
Spotted something outdated?