Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. Sunvolt
  4. SV-R30-BATTERY-S10.8

Home battery · Sunvolt · CEC approved June 2025

Sunvolt SV-R30-BATTERY-S10.8

A 9.66 kWh home battery.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
9.66kWhBelow the smaller-home band
Warranty
12yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

SV-R30-BATTERY-S10.8: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

What we can tell you

Read from the figures on this page. No review written yet.

  • 9.66 kWh is below the smaller-home band.
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
9.66kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the energy you store comes back out
Warranty
12yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Warranty and support

The warranty covers 12 years of performance for your electric storage system. It excludes claims due to non-accredited installations. To make a claim, fill out the warranty claim form found at the provided link.

Product
12 years; transferable; full replacement
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Not verifiedWe have not verified this brand's Australian support structure. Confirm warranty arrangements with the manufacturer or your installer.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the Sunvolt NA, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Nominal capacity
10.74 kWh
Usable capacity
9.66 kWh

Operating environment

Operating temperature
-10°C to 0°C

Installation requirements

Cable gauge
2.5 mm²

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetPDF, opens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guidePDF, opens in a new tab
  • User manualPDF, opens in a new tab
  • Compliance certificatePDF, opens in a new tab

Fault & error codes — Sunvolt NA

Extracted from the installation manual

26 documented

Showing 26 of 26. The official install manual is the authoritative source — always confirm before acting.

  • 09criticalCall your installer
    Manual (PDF)

    Short circuit on AC output

    Likely cause
    Load circuit short detected
    What to do
    Turn off the load breaker and check for shorts. Then turn the inverter on.
  • 16criticalCall your installer
    Manual (PDF)

    Over temperature fault

    Likely cause
    Inverter temperature exceeds safe operating limits.
    What to do
    Turn the inverter off and allow it to cool down before restarting.
  • 18criticalCall your installer
    Manual (PDF)

    Over power protection

    Likely cause
    Power output exceeds inverter capacity.
    What to do
    Turn off the inverter and ensure load is below 5kW before restarting.
  • 19criticalCall your installer
    Manual (PDF)

    PV insulation resistance is too low

    Likely cause
    Insulation failure in the PV system.
    What to do
    Turn off the PV breaker. Check insulation resistance.
  • 22criticalCall your installer
    Manual (PDF)

    Overload

    Likely cause
    Load exceeds available power output.
    What to do
    Reduce load and restart the inverter.
  • 01warningCall your installer
    Manual (PDF)

    DC bus voltage exceeds the upper threshold

    Likely cause
    PV voltage exceeds 500Vdc.
    What to do
    Turn off the inverter using the main switch and make sure PV voltage is below 500Vdc.
  • 02warningCall your installer
    Manual (PDF)

    Arc occurs on PV

    Likely cause
    Potential arcing detected on the PV input.
    What to do
    Turn the inverter off and then back on using the main switch.
  • 03warningCall your installer
    Manual (PDF)

    DC bus voltage falls below the lower threshold

    Likely cause
    Voltage at the battery is too low.
    What to do
    Turn the inverter on. Ensure the battery voltage is within 4 to 58Vdc.
  • 04warningCall your installer
    Manual (PDF)

    Parallel setting is not correct

    Likely cause
    Configuration settings for parallel operation are incorrect.
    What to do
    Check the parallel and mode setting, then turn the inverter off and back on.
  • 05warningCall your installer
    Manual (PDF)

    Battery discharging current exceeds the upper threshold

    Likely cause
    Load exceeds battery output limits.
    What to do
    Turn off the inverter and ensure the Grid and Load terminals are wired properly.
  • 06warningCall your installer
    Manual (PDF)

    Battery charging current exceeds the upper threshold

    Likely cause
    Too much current directed into the battery.
    What to do
    Turn the inverter off and back on. Check PV array for short circuits if the issue persists.
  • 07warningCall your installer
    Manual (PDF)

    Short circuit on PV1 input

    Likely cause
    Wiring issue or short circuit detected.
    What to do
    Turn the inverter off and back on. Inspect for short circuits on PV1.
  • 08warningCall your installer
    Manual (PDF)

    Short circuit on PV2 input

    Likely cause
    Wiring issue or short circuit detected.
    What to do
    Turn the inverter off and back on. Inspect for short circuits on PV2.
  • 10warningCall your installer
    Manual (PDF)

    Leakage current CT fault

    Likely cause
    Leakage current detected in the system.
    What to do
    Check for leaking appliances and ensure all connections are secure. Try resetting the inverter.
  • 11warningCall your installer
    Manual (PDF)

    DC/DC Current Sensor fault

    Likely cause
    Sensor failure detected.
    What to do
    Turn the inverter off and back on. If the issue persists, contact an installer.
  • 13warningCall your installer
    Manual (PDF)

    PV Current Sensor fault

    Likely cause
    Sensor malfunction detected.
    What to do
    Turn the inverter off and then back on.
  • 14warningCall your installer
    Manual (PDF)

    EEPROM read failure

    Likely cause
    Memory malfunction.
    What to do
    Turn the inverter off and then back on. If still not resolved, contact installer.
  • 15warningCall your installer
    Manual (PDF)

    Communication with main & secondary controllers are interrupted

    Likely cause
    Disconnected communication wires.
    What to do
    Turn the inverter off and then back on. Check communication connections.
  • 17warningCall your installer
    Manual (PDF)

    PV input voltage exceeds the upper threshold

    Likely cause
    Input voltage exceeds 500VDC.
    What to do
    Check PV input voltage and turn the inverter off if above the limit.
  • 20warningCall your installer
    Manual (PDF)

    Battery charging voltage is too high

    Likely cause
    Voltage from the battery exceeds acceptable limits.
    What to do
    Ensure connections are secure and turn the inverter off if necessary.
  • 21warningCall your installer
    Manual (PDF)

    Fan fault

    Likely cause
    Cooling fan is not operational.
    What to do
    Turn the inverter off and check the fan operation.
  • 23warningCall your installer
    Manual (PDF)

    PV input over power

    Likely cause
    Excessive power input from PV modules.
    What to do
    Ensure input from PV does not exceed 6.5kW before restarting the inverter.
  • 24warningCall your installer
    Manual (PDF)

    Battery type is wrong

    Likely cause
    Incorrect battery specification or settings.
    What to do
    Set the correct battery type before restarting the inverter.
  • 25warningCall your installer
    Manual (PDF)

    RCMU test fault

    Likely cause
    Communication or integrity fault in device.
    What to do
    Turn the inverter off and back on.
  • 26warningCall your installer
    Manual (PDF)

    Model setting fault

    Likely cause
    Configuration mismatch or error.
    What to do
    Turn the inverter off and check model settings before turning on again.
  • 27warningCall your installer
    Manual (PDF)

    Battery Voltage Drop

    Likely cause
    Battery voltage below 30V.
    What to do
    Check the battery connections and turn the inverter off and back on.

About Sunvolt

Years on the CEC list
1+ (CEC-approved products since 2025)
Local support
Not verified
CEC-listed products
6 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$2,594

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is below the smaller-home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 9.66 kWh battery

How it compares

The Sunvolt SV-R30-BATTERY-S10.8 against the closest-sized batteries from other brands.

Specification
Sunvolt SV-R30-BATTERY-S10.8Sunvolt
EcoFlow EF BD-10.2-S1EcoFlow
Green Solutions HOME E10Green Solutions
Usable capacity?9.66 kWh9.7 kWh✓highest9.7 kWh✓highest
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?Not verifiedNot verifiedNot verified
Warranty12 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?