Skip to main content
Solar Battery PerthSolar Battery Perth
  • Library
  • Compare
  • Calculate savings
  • Quote
  • Tools
Battery matcher
Battery matcher

Rebate and policy updates by email

What's changing with WA rebates and battery rules, for Perth homeowners.

Solar Battery Perth

WA-specific solar and battery tools with transparent installer matching for Synergy and Western Power customers.

  • 08 9429 8803
  • info@solarbatteryperth.com.au
Explore your optionsCompare products

Tools

  • Solar system quiz
  • Side-by-side comparison
  • Savings calculator
  • Tariff comparison
  • VPP earnings
  • Quote evaluator
  • Warranty comparison
  • Library
  • Product search
  • All tools

Information

  • How it works
  • Resources
  • WA rebates & incentives
  • Battery price index
  • Synergy tariffs
  • Financing
  • Getting started
  • Buyer's guide
  • Solar and battery integration
  • Battery scenarios

Get started

  • Find installers
  • Perth suburbs
  • Brands
  • Contact us
  • Common questions
Privacy policyTerms of useDisclaimerReview policyAffiliate disclosureAccessibility

© 2026 Solar Battery Perth, operated by WattMate Pty Ltd. Independent solar and battery resource for WA homeowners.

Installers pay us a flat $30 including GST per accepted lead, the same for every installer and every system. How it works

45 Ventnor Avenue, West Perth WA 6005

  • Home
  • Library
  • Compare
  • Savings
  • Quote
  1. Home
  2. Batteries
  3. OliPower
  4. OLP-EB-V309_E63-AO01

Home battery · OliPower · CEC approved March 2026

OliPower OLP-EB-V309_E63-AO01

A 60.48 kWh home battery. Very big home size, the 40+ kWh band.

WA Battery Scheme rebate
Depends on your inverterThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
Usable capacity
60.48kWh
Warranty
10yrs
Datasheet (PDF)

Get this battery quoted in Perth

Enter your postcode and get a free, no-obligation quote from a member installer who covers your area.

OLP-EB-V309_E63-AO01: the short answer

WA Battery SchemeThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter
ConditionalThe battery needs to pair with an inverter listed for battery storage on Synergy's list; we don't know your inverter

What we can tell you

Read from the figures on this page. No review written yet.

  • 60.48 kWh sits in the very big home band (40+ kWh).
  • It is CEC-approved, which is a condition of both the federal STC discount and the WA Battery Scheme.

Key specs, in plain terms

The numbers that matter for a home. The full datasheet is below.

Usable capacity
60.48kWh
How much energy it stores for you to use
Continuous power
Not on file: we don't have this figure from the manufacturer's documents yet
How much it can run at once
Round-trip efficiency
Not on file: we don't have this figure from the manufacturer's documents yet
How much of the energy you store comes back out
Warranty
10yr
How long the manufacturer stands behind it
Battery chemistry
LFP
Lithium iron phosphate, the long-cycle-life type
Size and weight
150kg
Installed weight

Not on file: we don’t have these figures from the manufacturer’s documents yet, so we leave them blank rather than print typical values. Ask your installer to confirm them on the quote. Seen it in a document? Tell us

Warranty and support

Warranty terms and Australian support structure.

Product
10 years
Throughput
Not on file
Installation
Must be installed by an SAA-accredited installer
Support
Australian supportAustralian support contact on record; 3 years on the CEC list. Confirm the claim process with your installer.
Perth heat
Rated to 45°C. Give it a shaded or indoor spot through Perth summers.

Warranty documentDatasheetCompare warranties

WA Battery Scheme eligibility

Conditional

Whether this battery pairs with an inverter listed for battery storage on Synergy's list, whether it can join a VPP, and whether it qualifies for the state rebate. Rebate and STC amounts are shown in the pricing panel.

This battery is AC-coupled. To get the WA rebate, the interest-free loan, VPP payments or DEBS export credits, it needs a gateway device from Synergy's approved list (for example SMA or Redback), or an inverter and battery from the same brand (Sungrow or Fronius). Without one, exports are capped at 1.5kW.

Some third-party gateways struggle to pass compliance testing, and adding anything to an AC-coupled system later means the whole system has to be re-checked. For many homes, switching to a hybrid (DC-coupled) inverter is the simpler path. AC vs DC coupling

CSIP-AUS compliant
Inverter must be CSIP-AUS compliant under the current WA framework.
VPP activation ready
Needs to pair with an inverter listed for battery storage on Synergy's list.
WA Battery Scheme rebate
Requires Battery Rewards participation under the current WA framework.
Synergy Battery Rewards
Requires a CSIP-AUS compliant system and reliable internet.
Interest-free loan
Not eligible for interest-free financing.

Under current WA rules, new rebate applications require VPP enrolment and CSIP-AUS compliance. How the scheme works · Estimate VPP earnings

Full datasheet

Every figure on file for the OliPower OLP-EB, by section.

Cell & chemistry

Chemistry
LFP

Capacity & power

Nominal capacity
63.67 kWh
Usable capacity
60.48 kWh

Physical

Weight
150 kg
IP rating
IP54

Operating environment

Operating temperature
-25°C to 45°C

Installation requirements

Top clearance
3 mm
Side clearance
3 mm
Front clearance
1 mm
AC breaker
10 A
Cable gauge
25 mm²
Earthing method
TN-S
DNSP pre-approval
No
Estimated install time
8 hrs

Parsed from the manufacturer datasheet, install manual, and warranty document. Confirm against the linked PDFs before relying on a value for a quote or installation.

Documents

  • DatasheetOpens in a new tab
  • Warranty termsOpens in a new tab
  • Installation guide and user manualPDF, opens in a new tab
  • Compliance certificateOpens in a new tab

Fault & error codes — OliPower OLP-EB

Extracted from the installation manual

40 documented

Showing 40 of 40. The official install manual is the authoritative source — always confirm before acting.

  • 1criticalCall your installer
    Manual (PDF)

    Overvoltage Fault of Battery Cell

    Likely cause
    1. BMS malfunction 2. Voltage collection point malfunction 3. Overcharging
    What to do
    Stop charging and replace BMS or check voltage collection point
  • 11criticalCall your installer
    Manual (PDF)

    Low Insulation Fault

    Likely cause
    1. Not grounded 2. Rainwater or liquids entering the equipment
    What to do
    Check grounding circuit and ensure equipment is dry
  • 14criticalCall your installer
    Manual (PDF)

    Fire Trigger

    Likely cause
    Temperature and smoke sensors triggered
    What to do
    Contact the manufacturer
  • 15criticalCall your installer
    Manual (PDF)

    BMS Communication Failure

    Likely cause
    1. BMS malfunction 2. BMS communication line disconnected
    What to do
    Replace BMS or check communication cable
  • 2criticalCall your installer
    Manual (PDF)

    Undervoltage Fault of Battery Cell

    Likely cause
    1. BMS malfunction 2. Voltage collection point malfunction 3. Long term non-charging
    What to do
    Charge in a timely manner and replace BMS or check voltage collection point
  • 3criticalCall your installer
    Manual (PDF)

    Battery Total Voltage Overvoltage Fault

    Likely cause
    Overcharging
    What to do
    Stop charging and check the inverter
  • 5criticalCall your installer
    Manual (PDF)

    High Temperature Fault During Battery Charging

    Likely cause
    1. BMS malfunction 2. Temperature collection point malfunction 3. Air Conditioning abnormal
    What to do
    Replace BMS or check air conditioning wiring harness
  • 7criticalCall your installer
    Manual (PDF)

    High Temperature Fault During Battery Discharge

    Likely cause
    1. BMS malfunction 2. Temperature collection point malfunction 3. Air Conditioning abnormal
    What to do
    Replace BMS or check air conditioning wiring harness
  • ALARM-01criticalCall your installer
    Manual (PDF)

    Earth fault alarm

    Likely cause
    Earth impedance of the PV arrays below safe level
    What to do
    Address potential earth faults immediately; consult installer
  • Battery Total Voltage Overvoltage FaultcriticalCall your installer
    Manual (PDF)

    Total battery voltage exceeds safe limits.

    Likely cause
    Overcharging.
    What to do
    Stop charging and check the inverter.
  • BESS_FAILUREcriticalCall your installer
    Manual (PDF)

    Battery Energy Storage System failure or maintenance required

    Likely cause
    A malfunction in the battery management system or battery itself
    What to do
    Contact your installer or technician immediately for service
  • BESS_FAULTcriticalCall your installer
    Manual (PDF)

    Battery Energy Storage System failure or maintenance required

    Likely cause
    Malfunction or issue with the battery system
    What to do
    Contact your installer or technician to check the battery system
  • BESS-01criticalCall your installer
    Manual (PDF)

    Battery Energy Storage System failure or maintenance required

    Likely cause
    Internal system malfunction or maintenance requirements
    What to do
    Contact your installer to investigate and resolve the issue
  • BMS Communication FailurecriticalCall your installer
    Manual (PDF)

    BMS is not communicating properly.

    Likely cause
    BMS malfunction; Communication line disconnected.
    What to do
    Replace BMS and check the communication cable.
  • Fire TriggercriticalCall your installer
    Manual (PDF)

    Fire alarm triggered by sensors.

    Likely cause
    The temperature sensor and smoke sensor are triggered simultaneously.
    What to do
    Contact the manufacturer immediately.
  • GRID-01criticalCall your installer
    Manual (PDF)

    Grid connection failure

    Likely cause
    Issues with grid connection or settings
    What to do
    Check grid connection settings; contact installer if necessary
  • High Temperature Fault During Battery ChargingcriticalCall your installer
    Manual (PDF)

    Battery temperature is too high during charging.

    Likely cause
    BMS malfunction; Temperature collection point malfunction; Air Conditioning Abnormal.
    What to do
    Replace BMS, check the temperature collection point, and check the air conditioner wiring harness.
  • High Temperature Fault During Battery DischargecriticalCall your installer
    Manual (PDF)

    Battery temperature is too high during discharge.

    Likely cause
    BMS malfunction; Temperature collection point malfunction; Air Conditioning Abnormal.
    What to do
    Replace BMS, check the temperature collection point, and check the air conditioner wiring harness.
  • Overvoltage Fault of Battery CellcriticalCall your installer
    Manual (PDF)

    Battery cell voltage is too high.

    Likely cause
    BMS malfunction; Voltage collection point malfunction; Overcharging.
    What to do
    Stop charging and check the inverter.
  • Undervoltage Fault of Battery CellcriticalCall your installer
    Manual (PDF)

    Battery cell voltage is too low.

    Likely cause
    BMS malfunction; Voltage collection point malfunction; Long term non-charging.
    What to do
    Charge in a timely manner and check the voltage collection point.
  • 10warning
    Manual (PDF)

    Battery Discharge Overcurrent Fault

    Likely cause
    Discharge current exceeds the maximum current of the battery
    What to do
    Reduce discharge power
  • 12warning
    Manual (PDF)

    SOC Low Alarm

    Likely cause
    Low battery level
    What to do
    Charge the battery
  • 13warning
    Manual (PDF)

    Air Conditioner Communication Failure

    Likely cause
    BMS and air conditioner communication line disconnected
    What to do
    Check the communication line between BMS and air conditioner
  • 16warning
    Manual (PDF)

    Emergency Stop Triggered

    Likely cause
    Wiring of the emergency stop function checked
    What to do
    Check the energy storage cabinet and restore it manually after no faults are found
  • 4warning
    Manual (PDF)

    Battery Total Voltage Undervoltage Fault

    Likely cause
    Long term non-charging
    What to do
    Charge in a timely manner and check the inverter
  • 6warningCall your installer
    Manual (PDF)

    Low Temperature Fault During Battery Charging

    Likely cause
    1. BMS malfunction 2. Temperature collection point malfunction 3. Air Conditioning abnormal
    What to do
    Replace BMS or check air conditioning wiring harness
  • 8warningCall your installer
    Manual (PDF)

    Low Temperature Fault During Battery Discharge

    Likely cause
    1. BMS malfunction 2. Temperature collection point malfunction 3. Air Conditioning abnormal
    What to do
    Replace BMS or check air conditioning wiring harness
  • 9warning
    Manual (PDF)

    Battery Charging Overcurrent Fault

    Likely cause
    Charging current exceeds the maximum current of the battery
    What to do
    Reduce charging power
  • AB-01warningCall your installer
    Manual (PDF)

    Battery abnormality

    Likely cause
    Battery not properly connected or malfunctioning
    What to do
    Check battery connections; contact installer if issue persists
  • Air Conditioner Communication FailurewarningCall your installer
    Manual (PDF)

    Failed communication between BMS and air conditioning system.

    Likely cause
    Communication line disconnected.
    What to do
    Check the communication line between BMS and air conditioner.
  • Battery Charging Overcurrent Faultwarning
    Manual (PDF)

    Charging current exceeds the maximum current of the battery.

    Likely cause
    Charging current is set too high.
    What to do
    Reduce charging power.
  • Battery Discharge Overcurrent Faultwarning
    Manual (PDF)

    Discharge current exceeds the maximum current of the battery.

    Likely cause
    Discharge current is set too high.
    What to do
    Reduce discharge power.
  • Battery Total Voltage Undervoltage FaultwarningCall your installer
    Manual (PDF)

    Total battery voltage is too low.

    Likely cause
    Long term non-charging.
    What to do
    Charge in a timely manner and check the inverter.
  • BATTERY_ABNORMALwarningCall your installer
    Manual (PDF)

    Battery abnormal alarm

    Likely cause
    Battery disconnection or malfunction
    What to do
    Check battery connections and status; contact installer if needed
  • Emergency Stop Triggeredwarning
    Manual (PDF)

    Emergency stop function has been activated.

    Likely cause
    Wiring issue with the emergency stop function.
    What to do
    Check the energy storage cabinet and restore it manually after no faults are found.
  • GRID_FAILUREwarning
    Manual (PDF)

    Grid failure alarm

    Likely cause
    Loss of power from the grid
    What to do
    Wait for grid recovery; if alarm persists, contact your installer
  • Low Insulation FaultwarningCall your installer
    Manual (PDF)

    Insulation of the device is compromised.

    Likely cause
    Not grounded; Moisture or liquid entering the equipment.
    What to do
    Check if the grounding circuit is installed correctly and if the equipment is wet.
  • Low Temperature Fault During Battery ChargingwarningCall your installer
    Manual (PDF)

    Battery temperature is too low during charging.

    Likely cause
    BMS malfunction; Temperature collection point malfunction; Air Conditioning Abnormal.
    What to do
    Replace BMS, check the temperature collection point, and check the air conditioner wiring harness.
  • Low Temperature Fault During Battery DischargewarningCall your installer
    Manual (PDF)

    Battery temperature is too low during discharge.

    Likely cause
    BMS malfunction; Temperature collection point malfunction; Air Conditioning.
    What to do
    Replace BMS, check the temperature collection point, and check the air conditioner wiring.
  • SOC Low Alarmwarning
    Manual (PDF)

    State of charge is low.

    Likely cause
    Battery level is depleted.
    What to do
    Charge processing.

About OliPower

Years on the CEC list
3+ (CEC-approved products since 2023)
Local support
Available
CEC-listed products
24 models
View full profile →

What it costs in Perth

We price batteries by size rather than by model. The average installed price before rebates:

10 kWh
$7,000–$9,000
20 kWh
$10,000–$15,000

Solar Battery Perth’s estimate, Oct 2026. Other sizes are not priced here, and a quote prices this model.

Rebates on this battery

WA Battery Scheme
Depends on your inverter
Federal STCs
−$6,943

The WA Battery Scheme (up to $1,300) needs VPP enrolment, and the battery needs to pair with an inverter listed for battery storage on Synergy's list. We don't know which inverter you'd pair this with, so we can't say whether it applies. Ask your installer. STCs assume about $39.9 a certificate.

Explore your options
  • Compare with the nearest batteries→
  • Already have a quote? Check it→
  • Get quotes on this battery→
  • Not sure what size you need?→

Which size band is your home?

Usable capacity, for one battery system

Smaller home
10 to 15 kWh
Medium home
20 to 30 kWh
Big home
30 to 40 kWh
Very big home
40+ kWh

This battery is one unit in the very big home band. The WA rebate caps at 10 kWh, but that is a rebate limit, not a sizing guide.

Does waiting change the rebate?

Estimated federal rebate (STCs) for this 60.48 kWh battery

How it compares

The OliPower OLP-EB-V309_E63-AO01 against the closest-sized batteries from other brands.

Specification
OliPower OLP-EB-V309_E63-AO01OliPower
Alpha ESS SMILE-BAT-15P IVAlpha ESS
GoodWe GW60KWH-D-10GoodWe
Usable capacity?60.48 kWh✓highest60.28 kWh60 kWh
Continuous power?Not verifiedNot verifiedNot verified
Peak power?Not verifiedNot verifiedNot verified
Round-trip efficiency?Not verifiedNot verifiedNot verified
Warranty10 yearsNot verifiedNot verified
ChemistryLFPLFPLFP

Specs from the CEC register and datasheet enrichment. Indicative: confirm exact figures with your installer.

More from OliPower

Other CEC-approved products from OliPower available in Australia.

OliPower Inverters

BRE-I-5K

5 kW

PCS-30K

30 kW · 3φ

PCS-60K

60 kW · 3φ

View all OliPower inverters
View full OliPower manufacturer profile

Want to take the next step?

Get a quote from a member installer who covers your area. You choose whether to act on it. No obligation.

We collect these details to prepare your quote match and to share with the installer(s) we match you with. Not providing them means we can't match you. Full collection notice.

Or explore your battery options first →

By requesting quotes you agree to be contacted by installers in our network about your enquiry. Part of WattMate Pty Ltd. No spam, opt out any time.

This model is one entry in the desk's index of solar batteries for Perth: every CEC-approved battery on one comparable dataset.

Product Information Disclaimer:

Product specifications, pricing, and availability are subject to change without notice. We make no warranties regarding product performance, longevity, or suitability for your specific needs.

Always verify specifications with the manufacturer and installer before purchase. Warranty terms are set by manufacturers and may have conditions not disclosed here. Battery performance degrades over time.

Explore your optionsCompare batteries
Spotted something outdated?